Large coal plants combine both ideas: steam is reheated between turbine sections and bled from several points to heat the feed water. This is the layout of most big thermal units.

How it works

  1. Superheated steam expands in the HP turbine.
  2. Part of the steam is bled to the high-pressure feed-water heaters.
  3. The rest returns to the boiler for reheat, then expands in the IP and LP turbines with more bleeds.
  4. Exhaust steam condenses, and the feed water is heated step by step before the boiler.