Calculations verification report

How the calculation blocks were checked against independent references.

Summary

Report date2026-11-25
Groups of calculations18
Verification cases216
Checks1521
ResultAll 1521 checks passed

What was checked, and how

Every case in this report runs a set of inputs through the same calculation a customer's block uses, and compares each result with a reference value that comes from somewhere else: a closed-form hand formula, a direct solution of the beam equation, an exact integration of the section or weld outline, the published ISO 5167-2 orifice equation, or an iterated solution of the Colebrook-White equation. The program's own formulas are never used to make a reference value. A check passes only when the difference is inside the allowance shown, which is no more than the rounding of the value the program displays, except where a published correlation is itself approximate (and then the allowance says so).

The same suite is re-run before every release. When it found a result that disagreed with its reference, the calculation was corrected before this report was issued; the report describes the version of the program with the date above.

What is and is not covered

  • Covered: straight beams with a concentrated load, a uniform load or an applied couple, six end conditions each (Roark cases 1, 3 and 5), including the plotted shear, moment and deflection curves; section properties of rectangles, circles, pipes, hollow sections, I-sections, channels and angles; pipe pressure drop (Darcy-Weisbach), pump head and power, orifice plates (ISO 5167), control valve sizing (IEC 60534-2-1); weld joints and weld groups treated as lines.
  • Not yet in this report: the pipe wall thickness blocks (ASME B31.1, B31.3, AS 4041, plastics) and the Indian Boiler Regulations blocks, which depend on the allowable-stress tables of the codes and need those tables as the reference; the pipe support span block; and the section utilisation check. Loading cases of the weld joints that use a simplified model (moment on a T joint, compression on a corner joint) have no published reference.
  • This is verification (is the program calculating the equations correctly?). It is not an external certification, and it does not replace the engineer's responsibility to choose the right model, enter the right data and check the result.

Beams (Roark cases 1, 3 and 5)

Straight beams with a concentrated load, a uniform load or an applied couple, for six end conditions each. The reference is the beam equation EI y'''' = q(x) solved directly for the same loads and end conditions (a separate calculation, not the program's formula tables). Lengths in mm, loads in N or N/mm, an applied couple in N.mm, E in MPa, I in mm4; moments are reported in N.m; a moment is positive when it sags the beam, a couple is positive clockwise.

Concentrated load 12 kN at 30 % of the span, left free, right fixed (cantilever)

Concentrated Load — Left Free, Right Fixed (Cantilever). Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at B 12,000 N 12,000 +0.0000 % Pass
Moment at B -25,200 N.m -25,200 0.0000 % Pass
Maximum moment 25,200 N.m 25,200 +0.0000 % Pass
Maximum deflection 3.57988 mm 3.57988 0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Concentrated load 12 kN at 70 % of the span, left free, right fixed (cantilever)

Concentrated Load — Left Free, Right Fixed (Cantilever). Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at B 12,000 N 12,000 +0.0000 % Pass
Moment at B -10,800 N.m -10,800 0.0000 % Pass
Maximum moment 10,800 N.m 10,800 +0.0000 % Pass
Maximum deflection 0.771882 mm 0.771882 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Uniform load 6 N/mm over the whole span, left free, right fixed (cantilever)

Uniform Load — Left Free, Right Fixed (Cantilever). Inputs: E = 200,000, I = 85,000,000, w = 6, L = 3,000.

QuantityReferenceProgramDifferenceResult
Reaction at B 18,000 N 18,000 +0.0000 % Pass
Moment at B -27,000 N.m -27,000 0.0000 % Pass
Maximum moment 27,000 N.m 27,000 +0.0000 % Pass
Maximum deflection 3.57353 mm 3.57353 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = -w with the end conditions; classical results: cantilever w L^4/(8EI) and w L^2/2, simply supported 5 w L^4/(384 EI) and w L^2/8, fixed-fixed w L^4/(384 EI) and w L^2/12. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 30 % of the span, left free, right fixed (cantilever)

End Couple — Left Free, Right Fixed (Cantilever). Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at B 0 N 0 0 Pass
Moment at B 15,000 N.m 15,000 +0.0000 % Pass
Maximum moment 15,000 N.m 15,000 +0.0000 % Pass
Maximum deflection 3.61324 mm 3.61324 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 70 % of the span, left free, right fixed (cantilever)

End Couple — Left Free, Right Fixed (Cantilever). Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at B 0 N 0 0 Pass
Moment at B 15,000 N.m 15,000 +0.0000 % Pass
Maximum moment 15,000 N.m 15,000 +0.0000 % Pass
Maximum deflection 2.025 mm 2.025 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Concentrated load 12 kN at 30 % of the span, left guided, right fixed

Concentrated Load — Left Guided, Right Fixed. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at B 12,000 N 12,000 +0.0000 % Pass
Moment at A 8,820 N.m 8,820 0.0000 % Pass
Moment at B -16,380 N.m -16,380 0.0000 % Pass
Maximum moment 16,380 N.m 16,380 +0.0000 % Pass
Maximum deflection 1.24518 mm 1.24518 0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Concentrated load 12 kN at 70 % of the span, left guided, right fixed

Concentrated Load — Left Guided, Right Fixed. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at B 12,000 N 12,000 +0.0000 % Pass
Moment at A 1,620 N.m 1,620 +0.0000 % Pass
Moment at B -9,180 N.m -9,180 0.0000 % Pass
Maximum moment 9,180 N.m 9,180 +0.0000 % Pass
Maximum deflection 0.343059 mm 0.343059 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Uniform load 6 N/mm over the whole span, left guided, right fixed

Uniform Load — Left Guided, Right Fixed. Inputs: E = 200,000, I = 85,000,000, w = 6, L = 3,000.

QuantityReferenceProgramDifferenceResult
Reaction at B 18,000 N 18,000 +0.0000 % Pass
Moment at A 9,000 N.m 9,000 +0.0000 % Pass
Moment at B -18,000 N.m -18,000 0.0000 % Pass
Maximum moment 18,000 N.m 18,000 +0.0000 % Pass
Maximum deflection 1.19118 mm 1.19118 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = -w with the end conditions; classical results: cantilever w L^4/(8EI) and w L^2/2, simply supported 5 w L^4/(384 EI) and w L^2/8, fixed-fixed w L^4/(384 EI) and w L^2/12. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 30 % of the span, left guided, right fixed

End Couple — Left Guided, Right Fixed. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A 0 N 0 0 Pass
Reaction at B 0 N 0 0 Pass
Moment at A -10,500 N.m -10,500 +0.0000 % Pass
Moment at B 4,500 N.m 4,500 +0.0000 % Pass
Maximum moment 10,500 N.m 10,500 +0.0000 % Pass
Maximum deflection 0.833824 mm 0.833824 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 70 % of the span, left guided, right fixed

End Couple — Left Guided, Right Fixed. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A 0 N 0 0 Pass
Reaction at B 0 N 0 0 Pass
Moment at A -4,500 N.m -4,500 +0.0000 % Pass
Moment at B 10,500 N.m 10,500 +0.0000 % Pass
Maximum moment 10,500 N.m 10,500 +0.0000 % Pass
Maximum deflection 0.833824 mm 0.833824 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Concentrated load 12 kN at 30 % of the span, left pinned, right fixed (propped cantilever)

Concentrated Load — Left Simply Supported, Right Fixed (Propped Cantilever). Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A 6,762 N 6,762 0.0000 % Pass
Reaction at B 5,238 N 5,238 +0.0000 % Pass
Moment at B -4,914 N.m -4,914 0.0000 % Pass
Maximum moment 6,085.8 N.m 6,085.8 0.0000 % Pass
Maximum deflection 0.169603 mm 0.169603 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Concentrated load 12 kN at 70 % of the span, left pinned, right fixed (propped cantilever)

Concentrated Load — Left Simply Supported, Right Fixed (Propped Cantilever). Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A 1,458 N 1,458 +0.0000 % Pass
Reaction at B 10,542 N 10,542 +0.0000 % Pass
Moment at B -6,426 N.m -6,426 0.0000 % Pass
Maximum moment 6,426 N.m 6,426 0.0000 % Pass
Maximum deflection 0.101895 mm 0.101895 0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Uniform load 6 N/mm over the whole span, left pinned, right fixed (propped cantilever)

Uniform Load — Left Simply Supported, Right Fixed (Propped Cantilever). Inputs: E = 200,000, I = 85,000,000, w = 6, L = 3,000.

QuantityReferenceProgramDifferenceResult
Reaction at A 6,750 N 6,750 +0.0000 % Pass
Reaction at B 11,250 N 11,250 +0.0000 % Pass
Moment at B -6,750 N.m -6,750 0.0000 % Pass
Maximum moment 6,750 N.m 6,750 +0.0000 % Pass
Maximum deflection 0.154837 mm 0.154531 -0.1979 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = -w with the end conditions; classical results: cantilever w L^4/(8EI) and w L^2/2, simply supported 5 w L^4/(384 EI) and w L^2/8, fixed-fixed w L^4/(384 EI) and w L^2/12. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 30 % of the span, left pinned, right fixed (propped cantilever)

End Couple — Left Simply Supported, Right Fixed (Propped). Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A -6,825 N -6,825 0.0000 % Pass
Reaction at B 6,825 N 6,825 +0.0000 % Pass
Moment at B -5,475 N.m -5,475 0.0000 % Pass
Maximum moment 8,857.5 N.m 8,857.5 +0.0000 % Pass
Maximum deflection 0.138168 mm 0.138168 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 70 % of the span, left pinned, right fixed (propped cantilever)

End Couple — Left Simply Supported, Right Fixed (Propped). Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A -3,825 N -3,825 +0.0000 % Pass
Reaction at B 3,825 N 3,825 +0.0000 % Pass
Moment at B 3,525 N.m 3,525 0.0000 % Pass
Maximum moment 8,032.5 N.m 8,032.5 +0.0000 % Pass
Maximum deflection 0.202842 mm 0.202842 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Concentrated load 12 kN at 30 % of the span, both ends fixed

Concentrated Load — Both Ends Fixed. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A 9,408 N 9,408 0.0000 % Pass
Reaction at B 2,592 N 2,592 +0.0000 % Pass
Moment at A -5,292 N.m -5,292 +0.0000 % Pass
Moment at B -2,268 N.m -2,268 0.0000 % Pass
Maximum moment 5,292 N.m 5,292 0.0000 % Pass
Maximum deflection 0.0680956 mm 0.0680956 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Concentrated load 12 kN at 70 % of the span, both ends fixed

Concentrated Load — Both Ends Fixed. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A 2,592 N 2,592 +0.0000 % Pass
Reaction at B 9,408 N 9,408 0.0000 % Pass
Moment at A -2,268 N.m -2,268 +0.0000 % Pass
Moment at B -5,292 N.m -5,292 0.0000 % Pass
Maximum moment 5,292 N.m 5,292 0.0000 % Pass
Maximum deflection 0.0680956 mm 0.0680956 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Uniform load 6 N/mm over the whole span, both ends fixed

Uniform Load — Both Ends Fixed. Inputs: E = 200,000, I = 85,000,000, w = 6, L = 3,000.

QuantityReferenceProgramDifferenceResult
Reaction at A 9,000 N 9,000 +0.0000 % Pass
Reaction at B 9,000 N 9,000 +0.0000 % Pass
Moment at A -4,500 N.m -4,500 0.0000 % Pass
Moment at B -4,500 N.m -4,500 0.0000 % Pass
Maximum moment 4,500 N.m 4,500 +0.0000 % Pass
Maximum deflection 0.0744485 mm 0.0744485 0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = -w with the end conditions; classical results: cantilever w L^4/(8EI) and w L^2/2, simply supported 5 w L^4/(384 EI) and w L^2/8, fixed-fixed w L^4/(384 EI) and w L^2/12. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 30 % of the span, both ends fixed

End Couple — Both Ends Fixed. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A -6,300 N -6,300 0.0000 % Pass
Reaction at B 6,300 N 6,300 +0.0000 % Pass
Moment at A -1,050 N.m -1,050 +0.0000 % Pass
Moment at B -4,950 N.m -4,950 0.0000 % Pass
Maximum moment 8,280 N.m 8,280 +0.0000 % Pass
Maximum deflection 0.119838 mm 0.119838 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 70 % of the span, both ends fixed

End Couple — Both Ends Fixed. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A -6,300 N -6,300 0.0000 % Pass
Reaction at B 6,300 N 6,300 +0.0000 % Pass
Moment at A 4,950 N.m 4,950 +0.0000 % Pass
Moment at B 1,050 N.m 1,050 0.0000 % Pass
Maximum moment 8,280 N.m 8,280 +0.0000 % Pass
Maximum deflection 0.119838 mm 0.119838 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Concentrated load 12 kN at 30 % of the span, both ends simply supported

Concentrated Load — Both Ends Simply Supported. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A 8,400 N 8,400 +0.0000 % Pass
Reaction at B 3,600 N 3,600 0.0000 % Pass
Maximum moment 7,560 N.m 7,560 +0.0000 % Pass
Maximum deflection 0.318402 mm 0.318402 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Concentrated load 12 kN at 70 % of the span, both ends simply supported

Concentrated Load — Both Ends Simply Supported. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A 3,600 N 3,600 0.0000 % Pass
Reaction at B 8,400 N 8,400 +0.0000 % Pass
Maximum moment 7,560 N.m 7,560 0.0000 % Pass
Maximum deflection 0.318402 mm 0.318402 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Uniform load 6 N/mm over the whole span, both ends simply supported

Uniform Load — Both Ends Simply Supported. Inputs: E = 200,000, I = 85,000,000, w = 6, L = 3,000.

QuantityReferenceProgramDifferenceResult
Reaction at A 9,000 N 9,000 +0.0000 % Pass
Reaction at B 9,000 N 9,000 +0.0000 % Pass
Maximum moment 6,750 N.m 6,750 +0.0000 % Pass
Maximum deflection 0.372243 mm 0.372243 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = -w with the end conditions; classical results: cantilever w L^4/(8EI) and w L^2/2, simply supported 5 w L^4/(384 EI) and w L^2/8, fixed-fixed w L^4/(384 EI) and w L^2/12. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 30 % of the span, both ends simply supported

End Couple — Both Ends Simply Supported. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at A -5,000 N -5,000 +0.0000 % Pass
Reaction at B 5,000 N 5,000 0.0000 % Pass
Maximum moment 10,500 N.m 10,500 +0.0000 % Pass
Maximum deflection 0.317736 mm 0.317736 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 70 % of the span, both ends simply supported

End Couple — Both Ends Simply Supported. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at A -5,000 N -5,000 +0.0000 % Pass
Reaction at B 5,000 N 5,000 0.0000 % Pass
Maximum moment 10,500 N.m 10,500 +0.0000 % Pass
Maximum deflection 0.317736 mm 0.317736 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Concentrated load 12 kN at 30 % of the span, left guided, right simply supported

Concentrated Load — Left Guided, Right Simply Supported. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Reaction at B 12,000 N 12,000 +0.0000 % Pass
Moment at A 25,200 N.m 25,200 +0.0000 % Pass
Maximum moment 25,200 N.m 25,200 +0.0000 % Pass
Maximum deflection 5.58106 mm 5.58106 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Concentrated load 12 kN at 70 % of the span, left guided, right simply supported

Concentrated Load — Left Guided, Right Simply Supported. Inputs: E = 200,000, I = 85,000,000, W = 12,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Reaction at B 12,000 N 12,000 +0.0000 % Pass
Moment at A 10,800 N.m 10,800 +0.0000 % Pass
Maximum moment 10,800 N.m 10,800 +0.0000 % Pass
Maximum deflection 2.77306 mm 2.77306 0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = q with the end conditions; classical results: cantilever tip load P L^3/(3EI), simply supported centre load P L^3/(48EI), fixed-fixed centre load P L^3/(192EI). Source: Beam theory (Euler-Bernoulli); Roark's Formulas for Stress and Strain, table of beam reactions and deflections.

Uniform load 6 N/mm over the whole span, left guided, right simply supported

Uniform Load — Left Guided, Right Simply Supported. Inputs: E = 200,000, I = 85,000,000, w = 6, L = 3,000.

QuantityReferenceProgramDifferenceResult
Reaction at B 18,000 N 18,000 +0.0000 % Pass
Moment at A 27,000 N.m 27,000 +0.0000 % Pass
Maximum moment 27,000 N.m 27,000 +0.0000 % Pass
Maximum deflection 5.95588 mm 5.95588 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = -w with the end conditions; classical results: cantilever w L^4/(8EI) and w L^2/2, simply supported 5 w L^4/(384 EI) and w L^2/8, fixed-fixed w L^4/(384 EI) and w L^2/12. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 30 % of the span, left guided, right simply supported

End Couple — Left Guided, Right Simply Supported. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 900.

QuantityReferenceProgramDifferenceResult
Moment at A -15,000 N.m -15,000 +0.0000 % Pass
Maximum moment 15,000 N.m 15,000 +0.0000 % Pass
Maximum deflection 2.025 mm 2.025 0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Applied couple 15e6 N.mm (15 kN.m) at 70 % of the span, left guided, right simply supported

End Couple — Left Guided, Right Simply Supported. Inputs: E = 200,000, I = 85,000,000, Mo = 15,000,000, L = 3,000, a = 2,100.

QuantityReferenceProgramDifferenceResult
Moment at A -15,000 N.m -15,000 +0.0000 % Pass
Maximum moment 15,000 N.m 15,000 +0.0000 % Pass
Maximum deflection 3.61324 mm 3.61324 +0.0000 % Pass
Plotted shear, moment and deflection curves at 25, 50 and 75 % of the span (9 points) each point against the reference curve; allowance 0.05 % of the curve's largest value worst point uses 0 % of the allowance Pass

Basis: Direct solution of EI y'''' = 0 with a jump of +Mo in the bending moment at the couple (clockwise positive) and the end conditions. Source: Beam theory (Euler-Bernoulli).

Section properties

Area, centroid, second moments, section moduli and radii of gyration of simple shapes. The reference is an exact polygon integration of the same outline (Green's theorem), a separate calculation from the program's per-shape formulas; the solid and hollow circles use their closed forms. x-x is the horizontal centroidal axis, y-y the vertical one; the sections are idealised (square corners, no fillets).

Rectangle 100 x 200 mm

Section Properties Calculator. Inputs: shape = rect, b = 100, d = 200.

QuantityReferenceProgramDifferenceResult
Area 20,000 mm2 20,000 +0.0000 % Pass
Centroid height 100 mm 100 +0.0000 % Pass
Second moment Ixx 66,666,667 mm4 66,666,667 +0.0000 % Pass
Second moment Iyy 16,666,667 mm4 16,666,667 +0.0000 % Pass
Section modulus Wxx 666,667 mm3 666,667 +0.0000 % Pass
Section modulus Wyy 333,333 mm3 333,333 +0.0000 % Pass
Radius of gyration rx 57.735 mm 57.735 +0.0000 % Pass
Radius of gyration ry 28.8675 mm 28.8675 +0.0000 % Pass

Basis: A = b d, Ixx = b d^3/12, Iyy = d b^3/12, W = I / (half the depth or width). Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Rectangle 40 x 300 mm

Section Properties Calculator. Inputs: shape = rect, b = 40, d = 300.

QuantityReferenceProgramDifferenceResult
Area 12,000 mm2 12,000 +0.0000 % Pass
Centroid height 150 mm 150 +0.0000 % Pass
Second moment Ixx 90,000,000 mm4 90,000,000 +0.0000 % Pass
Second moment Iyy 1,600,000 mm4 1,600,000 +0.0000 % Pass
Section modulus Wxx 600,000 mm3 600,000 +0.0000 % Pass
Section modulus Wyy 80,000 mm3 80,000 +0.0000 % Pass
Radius of gyration rx 86.6025 mm 86.6025 +0.0000 % Pass
Radius of gyration ry 11.547 mm 11.547 +0.0000 % Pass

Basis: A = b d, Ixx = b d^3/12, Iyy = d b^3/12. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Solid circle, diameter 100 mm

Section Properties Calculator. Inputs: shape = circle, D = 100.

QuantityReferenceProgramDifferenceResult
Area 7,853.98 mm2 7,853.98 +0.0000 % Pass
Centroid height 50 mm 50 +0.0000 % Pass
Second moment Ixx 4,908,739 mm4 4,908,739 +0.0000 % Pass
Second moment Iyy 4,908,739 mm4 4,908,739 +0.0000 % Pass
Section modulus Wxx 98,174.8 mm3 98,174.8 +0.0000 % Pass
Section modulus Wyy 98,174.8 mm3 98,174.8 +0.0000 % Pass
Radius of gyration rx 25 mm 25 +0.0000 % Pass
Radius of gyration ry 25 mm 25 +0.0000 % Pass

Basis: A = pi D^2/4, I = pi D^4/64, W = pi D^3/32. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Pipe 114.3 mm outside diameter, 6.0 mm wall

Section Properties Calculator. Inputs: shape = hollow_circle, D = 114.3, t = 6.

QuantityReferenceProgramDifferenceResult
Area 2,041.41 mm2 2,041.41 +0.0000 % Pass
Centroid height 57.15 mm 57.15 +0.0000 % Pass
Second moment Ixx 3,002,116 mm4 3,002,116 +0.0000 % Pass
Second moment Iyy 3,002,116 mm4 3,002,116 +0.0000 % Pass
Section modulus Wxx 52,530.5 mm3 52,530.5 +0.0000 % Pass
Section modulus Wyy 52,530.5 mm3 52,530.5 +0.0000 % Pass
Radius of gyration rx 38.3485 mm 38.3485 +0.0000 % Pass
Radius of gyration ry 38.3485 mm 38.3485 +0.0000 % Pass

Basis: A = pi (R^2 - r^2), I = pi (R^4 - r^4)/4. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Hollow rectangle 150 x 100 x 6 mm

Section Properties Calculator. Inputs: shape = rhs, b = 100, d = 150, t = 6.

QuantityReferenceProgramDifferenceResult
Area 2,856 mm2 2,856 +0.0000 % Pass
Centroid height 75 mm 75 +0.0000 % Pass
Second moment Ixx 8,852,472 mm4 8,852,472 +0.0000 % Pass
Second moment Iyy 4,663,072 mm4 4,663,072 +0.0000 % Pass
Section modulus Wxx 118,033 mm3 118,033 +0.0000 % Pass
Section modulus Wyy 93,261.4 mm3 93,261.4 +0.0000 % Pass
Radius of gyration rx 55.6741 mm 55.6741 +0.0000 % Pass
Radius of gyration ry 40.407 mm 40.407 +0.0000 % Pass

Basis: Outer rectangle minus inner rectangle: I = (b d^3 - bi di^3)/12. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Hollow square 100 x 100 x 5 mm

Section Properties Calculator. Inputs: shape = rhs, b = 100, d = 100, t = 5.

QuantityReferenceProgramDifferenceResult
Area 1,900 mm2 1,900 +0.0000 % Pass
Centroid height 50 mm 50 +0.0000 % Pass
Second moment Ixx 2,865,833 mm4 2,865,833 +0.0000 % Pass
Second moment Iyy 2,865,833 mm4 2,865,833 +0.0000 % Pass
Section modulus Wxx 57,316.7 mm3 57,316.7 +0.0000 % Pass
Section modulus Wyy 57,316.7 mm3 57,316.7 +0.0000 % Pass
Radius of gyration rx 38.8373 mm 38.8373 +0.0000 % Pass
Radius of gyration ry 38.8373 mm 38.8373 +0.0000 % Pass

Basis: Outer square minus inner square. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

I-section 150 flange, 10 flange, 8 web, 300 deep

Section Properties Calculator. Inputs: shape = i_beam, bf = 150, tf = 10, tw = 8, d = 300.

QuantityReferenceProgramDifferenceResult
Area 5,240 mm2 5,240 +0.0000 % Pass
Centroid height 150 mm 150 +0.0000 % Pass
Second moment Ixx 77,734,667 mm4 77,734,667 +0.0000 % Pass
Second moment Iyy 5,636,947 mm4 5,636,947 +0.0000 % Pass
Section modulus Wxx 518,231 mm3 518,231 +0.0000 % Pass
Section modulus Wyy 75,159.3 mm3 75,159.3 +0.0000 % Pass
Radius of gyration rx 121.798 mm 121.798 +0.0000 % Pass
Radius of gyration ry 32.7987 mm 32.7987 +0.0000 % Pass

Basis: Ixx = (bf d^3 - (bf - tw)(d - 2 tf)^3)/12; Iyy = (2 tf bf^3 + (d - 2 tf) tw^3)/12. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Channel 100 flange, 8 flange, 6 web, 200 deep

Section Properties Calculator. Inputs: shape = channel, bf = 100, tf = 8, tw = 6, d = 200.

QuantityReferenceProgramDifferenceResult
Area 2,704 mm2 2,704 +0.0000 % Pass
Centroid height 100 mm 100 +0.0000 % Pass
Second moment Ixx 17,868,885 mm4 17,868,885 +0.0000 % Pass
Second moment Iyy 2,779,684 mm4 2,779,684 +0.0000 % Pass
Section modulus Wxx 178,689 mm3 178,689 +0.0000 % Pass
Section modulus Wyy 40,175 mm3 40,175 +0.0000 % Pass
Radius of gyration rx 81.2915 mm 81.2915 +0.0000 % Pass
Radius of gyration ry 32.0623 mm 32.0623 +0.0000 % Pass

Basis: Centroid from the back of the web x0 = (2 bf tf bf/2 + tw (d - 2 tf) tw/2)/A; Iyy by the parallel-axis theorem. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Channel 75 flange, 10 flange, 7 web, 150 deep

Section Properties Calculator. Inputs: shape = channel, bf = 75, tf = 10, tw = 7, d = 150.

QuantityReferenceProgramDifferenceResult
Area 2,410 mm2 2,410 +0.0000 % Pass
Centroid height 75 mm 75 +0.0000 % Pass
Second moment Ixx 8,644,083 mm4 8,644,083 +0.0000 % Pass
Second moment Iyy 1,361,588 mm4 1,361,588 0.0000 % Pass
Section modulus Wxx 115,254 mm3 115,254 +0.0000 % Pass
Section modulus Wyy 27,048.8 mm3 27,048.8 0.0000 % Pass
Radius of gyration rx 59.8895 mm 59.8895 +0.0000 % Pass
Radius of gyration ry 23.7692 mm 23.7692 +0.0000 % Pass

Basis: Same as above. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Equal angle 100 x 100 x 10 mm

Section Properties Calculator. Inputs: shape = angle, b = 100, d = 100, tb = 10, td = 10.

QuantityReferenceProgramDifferenceResult
Area 1,900 mm2 1,900 +0.0000 % Pass
Centroid height 28.6842 mm 28.6842 +0.0000 % Pass
Second moment Ixx 1,800,044 mm4 1,800,044 +0.0000 % Pass
Second moment Iyy 1,800,044 mm4 1,800,044 0.0000 % Pass
Section modulus Wxx 25,240.5 mm3 25,240.5 +0.0000 % Pass
Section modulus Wyy 25,240.5 mm3 25,240.5 0.0000 % Pass
Radius of gyration rx 30.7797 mm 30.7797 +0.0000 % Pass
Radius of gyration ry 30.7797 mm 30.7797 0.0000 % Pass

Basis: A = 2 x 100 x 10 - 10^2 = 1900 mm2 (the corner square counted once). Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Unequal angle 150 x 90 x 12 mm

Section Properties Calculator. Inputs: shape = angle, b = 90, d = 150, tb = 12, td = 12.

QuantityReferenceProgramDifferenceResult
Area 2,736 mm2 2,736 +0.0000 % Pass
Centroid height 51.3947 mm 51.3947 +0.0000 % Pass
Second moment Ixx 6,318,006 mm4 6,318,006 +0.0000 % Pass
Second moment Iyy 1,743,126 mm4 1,743,126 +0.0000 % Pass
Section modulus Wxx 64,073.7 mm3 64,073.7 +0.0000 % Pass
Section modulus Wyy 25,408 mm3 25,408 +0.0000 % Pass
Radius of gyration rx 48.0543 mm 48.0543 +0.0000 % Pass
Radius of gyration ry 25.241 mm 25.241 +0.0000 % Pass

Basis: A = b tb + (d - tb) td; centroid and second moments by the parallel-axis theorem. Source: Standard section properties (Gere & Goodno, Mechanics of Materials; Young & Budynas, Roark, section properties table).

Hydraulics: pipe, pump, orifice and control valve

Darcy-Weisbach pipe friction, pump head and power, orifice plates (ISO 5167) and control valve sizing (IEC 60534-2-1 / ISA-75.01). The references are the same published equations evaluated separately (plain Python), the exact laminar solution (Hagen-Poiseuille), the Colebrook-White equation iterated to convergence and the discharge-coefficient example published with the ISO 5167-2 equation. The program rounds the values it shows, so each check allows one unit of the last digit shown.

Water in DN100 steel pipe, 60 m3/h, 250 m

Pipe Pressure Drop. Inputs: flow_rate = 60, pipe_diameter = 102.3, pipe_length = 250, fluid_density = 998.2, fluid_viscosity = 1.002, pipe_roughness = 0.046.

QuantityReferenceProgramDifferenceResult
Pressure drop 93.3082 kPa 93.3082 0.0000 % Pass
Velocity 2.02772 m/s 2.0277 -0.0009 % Pass
Reynolds number 206,649 206,649 +0.0001 % Pass
Friction factor (Swamee-Jain) 0.018606 0.018606 +0.0001 % Pass

Basis: Turbulent: Re = rho V D / mu, f from Swamee-Jain, dP = f (L/D) rho V^2 / 2. Source: Darcy-Weisbach equation; Swamee and Jain (1976), J. Hydraulics Div. ASCE 102(HY5).

Water in DN50 pipe, 20 m3/h, 100 m

Pipe Pressure Drop. Inputs: flow_rate = 20, pipe_diameter = 52.5, pipe_length = 100, fluid_density = 1,000, fluid_viscosity = 1, pipe_roughness = 0.046.

QuantityReferenceProgramDifferenceResult
Pressure drop 133.659 kPa 133.659 0.0000 % Pass
Velocity 2.56637 m/s 2.5664 +0.0012 % Pass
Reynolds number 134,734 134,734 -0.0003 % Pass
Friction factor (Swamee-Jain) 0.0213084 0.021308 -0.0019 % Pass

Basis: Turbulent, same equations. Source: Darcy-Weisbach equation; Swamee and Jain (1976), J. Hydraulics Div. ASCE 102(HY5).

Light oil (8 cP) in DN150 pipe, 150 m3/h, 500 m

Pipe Pressure Drop. Inputs: flow_rate = 150, pipe_diameter = 154.1, pipe_length = 500, fluid_density = 850, fluid_viscosity = 8, pipe_roughness = 0.046.

QuantityReferenceProgramDifferenceResult
Pressure drop 160.304 kPa 160.304 0.0000 % Pass
Velocity 2.23405 m/s 2.2341 +0.0021 % Pass
Reynolds number 36,578.4 36,578 -0.0012 % Pass
Friction factor (Swamee-Jain) 0.0232917 0.023292 +0.0011 % Pass

Basis: Turbulent, same equations. Source: Darcy-Weisbach equation; Swamee and Jain (1976), J. Hydraulics Div. ASCE 102(HY5).

Water in a smooth DN200 pipe, 300 m3/h, 1000 m

Pipe Pressure Drop. Inputs: flow_rate = 300, pipe_diameter = 202.7, pipe_length = 1,000, fluid_density = 998.2, fluid_viscosity = 1.002, pipe_roughness = 0.0015.

QuantityReferenceProgramDifferenceResult
Pressure drop 215.359 kPa 215.359 0.0000 % Pass
Velocity 2.58239 m/s 2.5824 +0.0005 % Pass
Reynolds number 521,465 521,465 +0.0000 % Pass
Friction factor (Swamee-Jain) 0.0131155 0.013116 +0.0037 % Pass

Basis: Turbulent, same equations (plastic pipe roughness 0.0015 mm). Source: Darcy-Weisbach equation; Swamee and Jain (1976), J. Hydraulics Div. ASCE 102(HY5).

Viscous oil (120 cP) in DN80 pipe, 5 m3/h, 60 m (laminar)

Pipe Pressure Drop. Inputs: flow_rate = 5, pipe_diameter = 80, pipe_length = 60, fluid_density = 900, fluid_viscosity = 120, pipe_roughness = 0.046.

QuantityReferenceProgramDifferenceResult
Pressure drop (Hagen-Poiseuille) 9.94718 kPa 9.9472 +0.0002 % Pass
Reynolds number 165.786 166 +0.1288 % Pass
Friction factor 64/Re 0.386039 0.386039 +0.0000 % Pass

Basis: Laminar flow: exact solution dP = 128 mu Q L / (pi D^4), f = 64/Re. Source: Hagen-Poiseuille law.

Water at 20 degC, carbon steel DN100 (NPS 4) standard wall, 60 m3/h, 250 m

Pipe Pressure Drop. Inputs: flow_rate = 60, pipe_length = 250, pipe_material = Carbon Steel, pipe_size = 100, fluid = water, fluid_temperature = 20.

QuantityReferenceProgramDifferenceResult
Inside diameter (OD - 2 x wall) 102.26 mm 102.26 +0.0000 % Pass
Pressure drop 93.4894 kPa 93.4859 -0.0038 % Pass
Velocity 2.0293 m/s 2.0293 -0.0002 % Pass
Roughness of the material 0.046 mm 0.046 +0.0000 % Pass

Basis: The inside diameter is the outside diameter minus twice the wall of the pipe chart (ASME B36.10M / B36.19M, ISO 4427 wall = OD / SDR), the roughness the piping system's material value; density and viscosity of water at 20 degC are the CoolProp / NIST values, which the program interpolates from its table (within 0.2 %). Source: ASME B36.10M, B36.19M, ISO 4427 (as printed in the app's pipe charts); CoolProp water properties; Darcy-Weisbach with Swamee-Jain.

Water at 20 degC, stainless steel DN80 (NPS 3) schedule 10S, 30 m3/h, 120 m

Pipe Pressure Drop. Inputs: flow_rate = 30, pipe_length = 120, pipe_material = Stainless Steel, pipe_size = 80, pipe_schedule = 10S, fluid = water, fluid_temperature = 20.

QuantityReferenceProgramDifferenceResult
Inside diameter (OD - 2 x wall) 82.8 mm 82.8 0.0000 % Pass
Pressure drop 31.454 kPa 31.4529 -0.0034 % Pass
Velocity 1.54763 m/s 1.5476 -0.0022 % Pass
Roughness of the material 0.015 mm 0.015 +0.0000 % Pass

Basis: The inside diameter is the outside diameter minus twice the wall of the pipe chart (ASME B36.10M / B36.19M, ISO 4427 wall = OD / SDR), the roughness the piping system's material value; density and viscosity of water at 20 degC are the CoolProp / NIST values, which the program interpolates from its table (within 0.2 %). Source: ASME B36.10M, B36.19M, ISO 4427 (as printed in the app's pipe charts); CoolProp water properties; Darcy-Weisbach with Swamee-Jain.

Water at 20 degC, HDPE DN110 SDR 11, 40 m3/h, 300 m

Pipe Pressure Drop. Inputs: flow_rate = 40, pipe_length = 300, pipe_material = HDPE, pipe_size = 110, pipe_schedule = SDR 11, fluid = water, fluid_temperature = 20.

QuantityReferenceProgramDifferenceResult
Inside diameter (OD - 2 x wall) 90 mm 90 +0.0000 % Pass
Pressure drop 83.3855 kPa 83.383 -0.0030 % Pass
Velocity 1.74656 m/s 1.7466 +0.0025 % Pass
Roughness of the material 0.0015 mm 0.0015 +0.0000 % Pass

Basis: The inside diameter is the outside diameter minus twice the wall of the pipe chart (ASME B36.10M / B36.19M, ISO 4427 wall = OD / SDR), the roughness the piping system's material value; density and viscosity of water at 20 degC are the CoolProp / NIST values, which the program interpolates from its table (within 0.2 %). Source: ASME B36.10M, B36.19M, ISO 4427 (as printed in the app's pipe charts); CoolProp water properties; Darcy-Weisbach with Swamee-Jain.

Swamee-Jain against Colebrook-White: water, D = 303.0 mm, roughness 0.046 mm, 800 m3/h

Pipe Pressure Drop. Inputs: flow_rate = 800, pipe_diameter = 303, pipe_length = 200, fluid_density = 998.2, fluid_viscosity = 1.002, pipe_roughness = 0.046.

QuantityReferenceProgramDifferenceResult
Friction factor (Colebrook-White, converged) 0.0141991 0.014279 +0.5625 % Pass
Pressure drop with the Colebrook-White friction factor 44.4285 kPa 44.6781 +0.5619 % Pass

Basis: The program uses the explicit Swamee-Jain correlation; the implicit Colebrook-White equation is solved by iteration here. Agreement within 1.5 % is expected (Swamee-Jain's stated accuracy is about 1 %). Source: Colebrook (1939); Swamee and Jain (1976).

Swamee-Jain against Colebrook-White: water, D = 80.0 mm, roughness 0.2 mm, 45 m3/h

Pipe Pressure Drop. Inputs: flow_rate = 45, pipe_diameter = 80, pipe_length = 200, fluid_density = 998.2, fluid_viscosity = 1.002, pipe_roughness = 0.2.

QuantityReferenceProgramDifferenceResult
Friction factor (Colebrook-White, converged) 0.0256461 0.025824 +0.6938 % Pass
Pressure drop with the Colebrook-White friction factor 197.892 kPa 199.267 +0.6948 % Pass

Basis: The program uses the explicit Swamee-Jain correlation; the implicit Colebrook-White equation is solved by iteration here. Agreement within 1.5 % is expected (Swamee-Jain's stated accuracy is about 1 %). Source: Colebrook (1939); Swamee and Jain (1976).

Water pump, 120 m3/h, 1.2 to 6.5 bar, +5 m

Pump Sizing. Inputs: flow_rate = 120, suction_pressure = 1.2, discharge_pressure = 6.5, fluid_density = 1,000, fluid_viscosity = 1, elevation_difference = 5, pump_efficiency = 75, vapor_pressure = 0.023.

QuantityReferenceProgramDifferenceResult
Total dynamic head 59.0265 m 59.03 +0.0059 % Pass
Shaft power 25.7356 kW 25.74 +0.0173 % Pass
NPSH available 11.998 m 12 +0.0170 % Pass
Specific speed (1450 rpm, m3/s, m) 12.4315 12.4 -0.2531 % Pass

Basis: H = (Pd - Ps)/(rho g) + dz, P = rho g H Q/eta, NPSHa = (Ps - Pv)/(rho g), Ns = N sqrt(Q)/H^0.75; g = 9.81 m/s2 as the program states. Source: Pump hydraulics (Bernoulli equation); Hydraulic Institute pump definitions.

Brine pump, 45 m3/h, 2.0 to 9.0 bar, -3 m

Pump Sizing. Inputs: flow_rate = 45, suction_pressure = 2, discharge_pressure = 9, fluid_density = 1,180, fluid_viscosity = 1, elevation_difference = -3, pump_efficiency = 68, vapor_pressure = 0.05.

QuantityReferenceProgramDifferenceResult
Total dynamic head 57.471 m 57.47 -0.0017 % Pass
Shaft power 12.2293 kW 12.23 +0.0059 % Pass
NPSH available 16.8455 m 16.85 +0.0268 % Pass
Specific speed (1450 rpm, m3/s, m) 7.7667 7.8 +0.4288 % Pass

Basis: H = (Pd - Ps)/(rho g) + dz, P = rho g H Q/eta, NPSHa = (Ps - Pv)/(rho g), Ns = N sqrt(Q)/H^0.75; g = 9.81 m/s2 as the program states. Source: Pump hydraulics (Bernoulli equation); Hydraulic Institute pump definitions.

Orifice plate, water, D 150 mm, d 75 mm (beta 0.5), 100 m3/h

Orifice Pressure Drop. Inputs: flow_rate = 100, pipe_diameter = 150, orifice_diameter = 75, fluid_density = 998, fluid_viscosity = 1.

QuantityReferenceProgramDifferenceResult
Differential pressure 50.5897 kPa 50.5897 +0.0000 % Pass
Beta ratio 0.5 0.5 +0.0000 % Pass
Discharge coefficient (ISO 5167-2) 0.60463 0.60463 -0.0001 % Pass
Velocity in the pipe 1.5719 m/s 1.5719 0.0000 % Pass
Velocity at the orifice 6.2876 m/s 6.2876 0.0000 % Pass
Reynolds number 235,314 235,314 +0.0002 % Pass
Permanent pressure loss (ISO 5167-2) 37.0687 kPa 37.0687 +0.0000 % Pass

Basis: Q = C E A_o sqrt(2 dP/rho) with E = 1/sqrt(1 - beta^4) and C from the Reader-Harris/Gallagher equation (D and D/2 taps, plus the small-pipe term under 71.12 mm); permanent loss from the ISO 5167-2 expression. Source: ISO 5167-1 and ISO 5167-2 (Reader-Harris/Gallagher equation). The equation as coded in this reference reproduces the published worked example of the open-source 'fluids' library (C = 0.5990326 for D 73.91 mm, d 22.2 mm, flange taps).

Orifice plate, light oil, D 200 mm, d 130 mm (beta 0.65), 220 m3/h

Orifice Pressure Drop. Inputs: flow_rate = 220, pipe_diameter = 200, orifice_diameter = 130, fluid_density = 850, fluid_viscosity = 6.

QuantityReferenceProgramDifferenceResult
Differential pressure 19.4053 kPa 19.4053 0.0000 % Pass
Beta ratio 0.65 0.65 +0.0000 % Pass
Discharge coefficient (ISO 5167-2) 0.617561 0.617561 0.0000 % Pass
Velocity in the pipe 1.94523 m/s 1.9452 -0.0014 % Pass
Velocity at the orifice 4.60409 m/s 4.6041 +0.0003 % Pass
Reynolds number 55,114.8 55,115 +0.0004 % Pass
Permanent pressure loss (ISO 5167-2) 10.9953 kPa 10.9953 +0.0003 % Pass

Basis: Q = C E A_o sqrt(2 dP/rho) with E = 1/sqrt(1 - beta^4) and C from the Reader-Harris/Gallagher equation (D and D/2 taps, plus the small-pipe term under 71.12 mm); permanent loss from the ISO 5167-2 expression. Source: ISO 5167-1 and ISO 5167-2 (Reader-Harris/Gallagher equation). The equation as coded in this reference reproduces the published worked example of the open-source 'fluids' library (C = 0.5990326 for D 73.91 mm, d 22.2 mm, flange taps).

Orifice plate in a small pipe, D 50 mm, d 25 mm, 12 m3/h

Orifice Pressure Drop. Inputs: flow_rate = 12, pipe_diameter = 50, orifice_diameter = 25, fluid_density = 998, fluid_viscosity = 1.

QuantityReferenceProgramDifferenceResult
Differential pressure 58.1898 kPa 58.1898 +0.0000 % Pass
Beta ratio 0.5 0.5 +0.0000 % Pass
Discharge coefficient (ISO 5167-2) 0.608866 0.608866 +0.0001 % Pass
Velocity in the pipe 1.69765 m/s 1.6977 +0.0028 % Pass
Velocity at the orifice 6.79061 m/s 6.7906 -0.0002 % Pass
Reynolds number 84,712.9 84,713 +0.0002 % Pass
Permanent pressure loss (ISO 5167-2) 42.5455 kPa 42.5455 +0.0000 % Pass

Basis: Q = C E A_o sqrt(2 dP/rho) with E = 1/sqrt(1 - beta^4) and C from the Reader-Harris/Gallagher equation (D and D/2 taps, plus the small-pipe term under 71.12 mm); permanent loss from the ISO 5167-2 expression. Source: ISO 5167-1 and ISO 5167-2 (Reader-Harris/Gallagher equation). The equation as coded in this reference reproduces the published worked example of the open-source 'fluids' library (C = 0.5990326 for D 73.91 mm, d 22.2 mm, flange taps).

Orifice flow from a 40 kPa differential, D 150 mm, d 75 mm, water

Orifice Flow Rate. Inputs: pipe_diameter = 150, orifice_diameter = 75, differential_pressure = 40, fluid_density = 998, fluid_viscosity = 1.

QuantityReferenceProgramDifferenceResult
Volumetric flow 88.9455 m3/h 88.9455 +0.0000 % Pass
Mass flow 88,767.6 kg/h 88,767.6 0.0000 % Pass
Discharge coefficient 0.604804 0.604804 0.0000 % Pass
Reynolds number 209,301 209,301 +0.0001 % Pass

Basis: The flow that gives the stated differential pressure, found by bisection with the Reynolds-number dependent coefficient (the program iterates the same relation). Source: ISO 5167-1, ISO 5167-2.

Orifice flow from a 25 kPa differential, D 100 mm, d 50 mm, oil 15 cP

Orifice Flow Rate. Inputs: pipe_diameter = 100, orifice_diameter = 50, differential_pressure = 25, fluid_density = 870, fluid_viscosity = 15.

QuantityReferenceProgramDifferenceResult
Volumetric flow 34.396 m3/h 34.396 0.0000 % Pass
Mass flow 29,924.5 kg/h 29,924.5 0.0000 % Pass
Discharge coefficient 0.621493 0.621493 +0.0001 % Pass
Reynolds number 7,055.76 7,056 +0.0034 % Pass

Basis: The flow that gives the stated differential pressure, found by bisection with the Reynolds-number dependent coefficient (the program iterates the same relation). Source: ISO 5167-1, ISO 5167-2.

Size an orifice for 100 m3/h and 40 kPa, D 150 mm, water

Orifice Sizing. Inputs: flow_rate = 100, pipe_diameter = 150, pressure_drop = 40, fluid_density = 998, fluid_viscosity = 1.

QuantityReferenceProgramDifferenceResult
Orifice diameter 79.134 mm 79.13 -0.0050 % Pass
Beta ratio 0.52756 0.5276 +0.0076 % Pass
Discharge coefficient 0.605891 0.605891 +0.0000 % Pass
Orifice area 4,918.31 mm2 4,918.31 +0.0000 % Pass
Reynolds number 235,314 235,314 +0.0002 % Pass

Basis: The bore that gives the allowed differential pressure at the stated flow, found by bisection on beta with the ISO 5167-2 coefficient. Source: ISO 5167-1, ISO 5167-2.

Size an orifice for 30 m3/h and 20 kPa, D 100 mm, oil 12 cP

Orifice Sizing. Inputs: flow_rate = 30, pipe_diameter = 100, pressure_drop = 20, fluid_density = 880, fluid_viscosity = 12.

QuantityReferenceProgramDifferenceResult
Orifice diameter 49.6058 mm 49.61 +0.0085 % Pass
Beta ratio 0.496058 0.4961 +0.0085 % Pass
Discharge coefficient 0.619886 0.619886 +0.0001 % Pass
Orifice area 1,932.66 mm2 1,932.66 +0.0001 % Pass
Reynolds number 7,780.91 7,781 +0.0012 % Pass

Basis: The bore that gives the allowed differential pressure at the stated flow, found by bisection on beta with the ISO 5167-2 coefficient. Source: ISO 5167-1, ISO 5167-2.

Beta ratio of a 60 mm bore in a 150 mm pipe

Orifice Beta Ratio. Inputs: pipe_diameter = 150, orifice_diameter = 60.

QuantityReferenceProgramDifferenceResult
Beta ratio 0.4 0.4 +0.0000 % Pass

Basis: beta = d / D. Source: ISO 5167-1.

Orifice K factor, beta 0.50, C = 0.61

Orifice K Factor. Inputs: pipe_diameter = 150, orifice_diameter = 75, discharge_coefficient = 0.61.

QuantityReferenceProgramDifferenceResult
K factor (on the pipe velocity head) 40.3117 40.3117 -0.0001 % Pass
Beta ratio 0.5 0.5 +0.0000 % Pass

Basis: K = (1 - beta^4) / (C^2 beta^4), from dP = K rho V^2/2 with the orifice equation. Source: ISO 5167-1.

Orifice K factor, beta 0.70, C = 0.6

Orifice K Factor. Inputs: pipe_diameter = 100, orifice_diameter = 70, discharge_coefficient = 0.6.

QuantityReferenceProgramDifferenceResult
K factor (on the pipe velocity head) 8.79148 8.7915 +0.0003 % Pass
Beta ratio 0.7 0.7 +0.0000 % Pass

Basis: K = (1 - beta^4) / (C^2 beta^4), from dP = K rho V^2/2 with the orifice equation. Source: ISO 5167-1.

Size a control valve: 80 m3/h water, P1 900 kPa, dP 150 kPa

Control Valve Sizing. Inputs: flow_rate = 80, upstream_pressure = 900, differential_pressure = 150, fluid_density = 998, vapor_pressure = 2.34, critical_pressure = 22,064, pressure_recovery_factor = 0.9.

QuantityReferenceProgramDifferenceResult
Flow coefficient Kv 65.2544 m3/h 65.2544 +0.0000 % Pass
Flow coefficient Cv 75.4341 US 75.4341 +0.0001 % Pass
Largest non-choked differential pressure 727.186 kPa 727.186 +0.0000 % Pass
Differential pressure used 150 kPa 150 +0.0000 % Pass
Critical pressure ratio factor FF 0.957116 0.9571 -0.0017 % Pass

Basis: Kv = Q sqrt((rho/rho0)/dP) with dP in bar; FF = 0.96 - 0.28 sqrt(Pv/Pc); dP(choked) = FL^2 (P1 - FF Pv); Cv = 1.156 Kv. The program's 'pressure recovery factor' is the liquid pressure recovery factor FL of the standard. Source: IEC 60534-2-1 and ISA-75.01.01, liquid sizing.

Size a control valve in choked flow: 40 m3/h, P1 500 kPa, dP 480 kPa

Control Valve Sizing. Inputs: flow_rate = 40, upstream_pressure = 500, differential_pressure = 480, fluid_density = 998, vapor_pressure = 3.17, critical_pressure = 22,064, pressure_recovery_factor = 0.85.

QuantityReferenceProgramDifferenceResult
Flow coefficient Kv 21.0883 m3/h 21.0883 -0.0002 % Pass
Flow coefficient Cv 24.3781 US 24.3781 -0.0001 % Pass
Largest non-choked differential pressure 359.059 kPa 359.059 +0.0000 % Pass
Differential pressure used 359.059 kPa 359.059 +0.0000 % Pass
Critical pressure ratio factor FF 0.956644 0.9566 -0.0046 % Pass

Basis: Kv = Q sqrt((rho/rho0)/dP) with dP in bar; FF = 0.96 - 0.28 sqrt(Pv/Pc); dP(choked) = FL^2 (P1 - FF Pv); Cv = 1.156 Kv. The program's 'pressure recovery factor' is the liquid pressure recovery factor FL of the standard. Source: IEC 60534-2-1 and ISA-75.01.01, liquid sizing.

Flow through a valve of Kv 120, P1 900 kPa, dP 150 kPa

Control Valve Flow Rate. Inputs: kv = 120, upstream_pressure = 900, differential_pressure = 150, fluid_density = 998, vapor_pressure = 2.34, critical_pressure = 22,064, pressure_recovery_factor = 0.9.

QuantityReferenceProgramDifferenceResult
Volumetric flow 147.117 m3/h 147.117 +0.0000 % Pass
Mass flow 146,822 kg/h 146,822 0.0000 % Pass
Largest non-choked differential pressure 727.186 kPa 727.186 +0.0000 % Pass
Differential pressure used 150 kPa 150 +0.0000 % Pass

Basis: Q = Kv sqrt(dP/(rho/rho0)) with dP in bar, limited at the choked differential pressure. Source: IEC 60534-2-1 and ISA-75.01.01, liquid sizing.

Flow through a valve of Kv 60 at a differential above the choked limit

Control Valve Flow Rate. Inputs: kv = 60, upstream_pressure = 500, differential_pressure = 480, fluid_density = 998, vapor_pressure = 3.17, critical_pressure = 22,064, pressure_recovery_factor = 0.85.

QuantityReferenceProgramDifferenceResult
Volumetric flow 113.807 m3/h 113.807 +0.0000 % Pass
Mass flow 113,579 kg/h 113,579 +0.0000 % Pass
Largest non-choked differential pressure 359.059 kPa 359.059 +0.0000 % Pass
Differential pressure used 359.059 kPa 359.059 +0.0000 % Pass

Basis: Q = Kv sqrt(dP/(rho/rho0)) with dP in bar, limited at the choked differential pressure. Source: IEC 60534-2-1 and ISA-75.01.01, liquid sizing.

Pressure drop across a valve of Kv 120 at 80 m3/h, P1 900 kPa

Control Valve Pressure Drop. Inputs: kv = 120, flow_rate = 80, fluid_density = 998, upstream_pressure = 900, vapor_pressure = 2.34, critical_pressure = 22,064, pressure_recovery_factor = 0.9.

QuantityReferenceProgramDifferenceResult
Pressure drop 44.3556 kPa 44.3556 +0.0001 % Pass
Unchoked differential pressure 44.3556 kPa 44.3556 +0.0001 % Pass
Largest non-choked differential pressure 727.186 kPa 727.186 +0.0000 % Pass

Basis: dP = (Q/Kv)^2 (rho/rho0), in bar then kPa. Source: IEC 60534-2-1 and ISA-75.01.01, liquid sizing.

Cavitation index, P1 600 kPa, dP 250 kPa

Control Valve Cavitation. Inputs: upstream_pressure = 600, differential_pressure = 250, vapor_pressure = 3.17.

QuantityReferenceProgramDifferenceResult
Cavitation index sigma 2.38732 2.3873 -0.0008 % Pass
Differential pressure at sigma = 1.5 397.887 kPa 397.887 +0.0000 % Pass

Basis: sigma = (P1 - Pv)/dP; the incipient-cavitation line is taken at sigma = 1.5 (the program's published rule of thumb). Source: ISA-RP75.23 (cavitation index); manufacturers' sizing practice.

Cavitation index, P1 450 kPa, dP 380 kPa

Control Valve Cavitation. Inputs: upstream_pressure = 450, differential_pressure = 380, vapor_pressure = 7.4.

QuantityReferenceProgramDifferenceResult
Cavitation index sigma 1.16474 1.1647 -0.0032 % Pass
Differential pressure at sigma = 1.5 295.067 kPa 295.067 +0.0000 % Pass

Basis: sigma = (P1 - Pv)/dP; the incipient-cavitation line is taken at sigma = 1.5 (the program's published rule of thumb). Source: ISA-RP75.23 (cavitation index); manufacturers' sizing practice.

Welded connections: joints

Fillet and butt weld joints: throat, effective area, stress, allowable stress, factor of safety and capacity. The references are the hand formulas written in each case; the program rounds the values it shows, so each check allows one unit of the last digit shown. Loading cases with a simplified model of the joint (moment on a T joint, compression on a corner joint) are not covered by a published reference and are not part of this report.

Single transverse fillet, leg 8 mm, length 200 mm, 150 kN, E70

Single Transverse Fillet — Lap Joint. Inputs: h = 8, L = 200, electrode = E70, P = 150,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 5.65685 mm 5.66 +0.0556 % Pass
Effective throat area 1,131.37 mm2 1,131.37 -0.0001 % Pass
Actual shear stress 132.583 MPa 132.58 -0.0019 % Pass
Allowable shear stress 144.9 MPa 144.9 +0.0000 % Pass
Factor of safety 1.0929 1.093 +0.0088 % Pass
Load capacity 163,936 N 163,936 0.0000 % Pass

Basis: Throat area = (h/sqrt(2)) L; stress = P / area. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Single transverse fillet, leg 6 mm, length 120 mm, 60 kN, E43

Single Transverse Fillet — Lap Joint. Inputs: h = 6, L = 120, electrode = E43, P = 60,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 4.24264 mm 4.24 -0.0622 % Pass
Effective throat area 509.117 mm2 509.12 +0.0006 % Pass
Actual shear stress 117.851 MPa 117.85 -0.0010 % Pass
Allowable shear stress 129 MPa 129 +0.0000 % Pass
Factor of safety 1.0946 1.095 +0.0364 % Pass
Load capacity 65,676.1 N 65,676.1 +0.0000 % Pass

Basis: Throat area = (h/sqrt(2)) L; stress = P / area. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Double transverse fillet, leg 10 mm, 150 mm each, 300 kN

Double Transverse Fillet — Lap Joint. Inputs: h = 10, L = 150, electrode = E70, P = 300,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 7.07107 mm 7.07 -0.0151 % Pass
Effective throat area 2,121.32 mm2 2,121.32 0.0000 % Pass
Actual shear stress 141.421 MPa 141.42 -0.0010 % Pass
Allowable shear stress 144.9 MPa 144.9 +0.0000 % Pass
Factor of safety 1.0246 1.025 +0.0393 % Pass
Load capacity 307,379 N 307,379 0.0000 % Pass

Basis: Throat area = (h/sqrt(2)) 2L. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Parallel side fillets, leg 8 mm, 180 mm each side, 200 kN

Parallel (Side) Fillet — Lap Joint. Inputs: h = 8, L = 180, electrode = E49, P = 200,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 5.65685 mm 5.66 +0.0556 % Pass
Effective throat area 2,036.47 mm2 2,036.47 +0.0001 % Pass
Actual shear stress 98.2093 MPa 98.21 +0.0007 % Pass
Allowable shear stress 147 MPa 147 +0.0000 % Pass
Factor of safety 1.4968 1.497 +0.0131 % Pass
Load capacity 299,361 N 299,361 0.0000 % Pass

Basis: Throat area = (h/sqrt(2)) 2L. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Combined transverse and parallel fillets, leg 8 mm, 250 kN

Combined Transverse + Parallel Fillet — Lap Joint. Inputs: h = 8, L_t = 100, L_p = 150, n_t = 2, n_p = 2, electrode = E70, P = 250,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 5.65685 mm 5.66 +0.0556 % Pass
Transverse throat area 1,131.37 mm2 1,131.37 -0.0001 % Pass
Parallel throat area 1,697.06 mm2 1,697.06 +0.0002 % Pass
Total throat area 2,828.43 mm2 2,828.43 +0.0001 % Pass
Actual shear stress 88.3883 MPa 88.39 +0.0019 % Pass
Allowable shear stress 144.9 MPa 144.9 +0.0000 % Pass
Factor of safety 1.63936 1.639 -0.0217 % Pass
Load capacity 409,839 N 409,839 +0.0000 % Pass

Basis: Throat area = (h/sqrt(2)) (nt Lt + np Lp); stress = P / total area. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Double fillet T joint in shear, leg 8 mm, 200 mm each side, 100 kN

Double Fillet — T-Joint. Inputs: h = 8, L = 200, tw = 10, electrode = E70, loading = shear, e = 0, P = 100,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 5.65685 mm 5.66 +0.0556 % Pass
Effective throat area 2,262.74 mm2 2,262.74 -0.0001 % Pass
Actual shear stress 44.1942 MPa 44.19 -0.0094 % Pass
Allowable shear stress 144.9 MPa 144.9 +0.0000 % Pass
Factor of safety 3.27871 3.279 +0.0088 % Pass
Load capacity 327,871 N 327,871 +0.0000 % Pass

Basis: Two fillets of length L: throat area = (h/sqrt(2)) 2L. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Corner joint in shear, leg 10 mm, 150 mm, 90 kN

Fillet Weld — Corner Joint. Inputs: h = 10, L = 150, electrode = E70, loading = shear, P = 90,000.

QuantityReferenceProgramDifferenceResult
Throat thickness 7.07107 mm 7.07 -0.0151 % Pass
Effective throat area 2,121.32 mm2 2,121.32 0.0000 % Pass
Actual shear stress 42.4264 MPa 42.43 +0.0085 % Pass
Allowable shear stress 144.9 MPa 144.9 +0.0000 % Pass
Factor of safety 3.41533 3.415 -0.0095 % Pass
Load capacity 307,379 N 307,379 0.0000 % Pass

Basis: Throat area = (h/sqrt(2)) 2L. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Full penetration butt weld in tension, plate 12 mm x 200 mm, fy 250 MPa

Full Penetration Butt Weld. Inputs: t = 12, L = 200, fy = 250, electrode = E70, loading = tension, P = 300,000.

QuantityReferenceProgramDifferenceResult
Effective area 2,400 mm2 2,400 +0.0000 % Pass
Actual stress 125 MPa 125 +0.0000 % Pass
Allowable stress 150 MPa 150 +0.0000 % Pass
Factor of safety 1.2 1.2 +0.0000 % Pass
Load capacity 360,000 N 360,000 +0.0000 % Pass

Basis: Effective area = t L (full penetration); allowable stress 0.6 fy in tension, 0.4 fy in shear. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Full penetration butt weld in shear, plate 16 mm x 150 mm, fy 350 MPa

Full Penetration Butt Weld. Inputs: t = 16, L = 150, fy = 350, electrode = E70, loading = shear, P = 250,000.

QuantityReferenceProgramDifferenceResult
Effective area 2,400 mm2 2,400 +0.0000 % Pass
Actual stress 104.167 MPa 104.17 +0.0032 % Pass
Allowable stress 140 MPa 140 +0.0000 % Pass
Factor of safety 1.344 1.344 +0.0000 % Pass
Load capacity 336,000 N 336,000 +0.0000 % Pass

Basis: Effective area = t L (full penetration); allowable stress 0.6 fy in tension, 0.4 fy in shear. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Partial penetration butt weld, plate 20 mm, weld depth 12 mm, 180 mm

Partial Penetration Butt Weld. Inputs: t = 20, weld_depth = 12, L = 180, fy = 250, electrode = E70, loading = tension, P = 200,000.

QuantityReferenceProgramDifferenceResult
Effective throat 12 mm 12 +0.0000 % Pass
Effective area 2,160 mm2 2,160 +0.0000 % Pass
Actual stress 92.5926 MPa 92.59 -0.0028 % Pass
Allowable stress 150 MPa 150 +0.0000 % Pass
Factor of safety 1.62 1.62 +0.0000 % Pass
Load capacity 324,000 N 324,000 +0.0000 % Pass

Basis: Effective area = weld depth x L; allowable stress 0.6 fy in tension. Source: Fillet weld throat a = h/sqrt(2); allowable shear stress 0.3 x electrode tensile strength; butt welds 0.6 fy (tension) and 0.4 fy (shear) on the effective area.

Welded connections: weld groups (welds treated as lines)

Unit second and polar moments of the weld pattern, the largest resultant force per unit length under in-plane shear, out-of-plane shear, bending and torsion, and the required and available weld size. The reference integrates the pattern as straight lines and searches ALL points of the weld for the largest force; torsion Mz is positive clockwise. Fillet strength: phi 0.8 x 0.6 x throat x electrode strength.

Single line weld, 200 mm: out-of-plane shear and bending about its length

Single Line Weld. Inputs: L = 200, electrode = E70, h = 6, Fz = 30,000, My = 2,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 0 mm3 0 0 Pass
Unit second moment Iyy 666,667 mm3 666,667 +0.0000 % Pass
Unit polar moment J 666,667 mm3 666,667 +0.0000 % Pass
Total weld length 200 mm 200 +0.0000 % Pass
Largest resultant force per length 450 N/mm 450 +0.0000 % Pass
Required throat 1.5528 mm 1.553 +0.0132 % Pass
Required leg size 2.19598 mm 2.196 +0.0007 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 2.18581 2.186 +0.0088 % Pass

Basis: A = L, Iyy = L^3/12 (unit), force per length = Fz/L + My x/Iyy at the ends of the line. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Single line weld, 200 mm: in-plane shear and torsion

Single Line Weld. Inputs: L = 200, electrode = E70, h = 6, Fx = 10,000, Fy = 25,000, Mz = 1,500,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 0 mm3 0 0 Pass
Unit second moment Iyy 666,667 mm3 666,667 +0.0000 % Pass
Unit polar moment J 666,667 mm3 666,667 +0.0000 % Pass
Total weld length 200 mm 200 +0.0000 % Pass
Largest resultant force per length 353.553 N/mm 353.55 -0.0010 % Pass
Required throat 1.21999 mm 1.22 +0.0007 % Pass
Required leg size 1.72533 mm 1.725 -0.0190 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 2.78208 2.782 -0.0029 % Pass

Basis: Direct shear F/L plus torsion Mz r/J with J = Ixx + Iyy. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Two parallel welds, 150 mm long, 100 mm apart: shear, bending and torsion

Two Parallel Line Welds. Inputs: L = 150, b = 100, electrode = E70, h = 6, Fx = 15,000, Fy = 10,000, Fz = 20,000, Mx = 3,000,000, My = 2,000,000, Mz = 4,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 750,000 mm3 750,000 +0.0000 % Pass
Unit second moment Iyy 562,500 mm3 562,500 +0.0000 % Pass
Unit polar moment J 1,312,500 mm3 1,312,500 +0.0000 % Pass
Total weld length 300 mm 300 +0.0000 % Pass
Largest resultant force per length 602.927 N/mm 602.93 +0.0006 % Pass
Required throat 2.08049 mm 2.08 -0.0236 % Pass
Required leg size 2.94226 mm 2.942 -0.0088 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 1.6314 1.631 -0.0245 % Pass

Basis: A = 2L, Ixx = 2 L (b/2)^2, Iyy = 2 L^3/12. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Two parallel welds: out-of-plane load and bending only

Two Parallel Line Welds. Inputs: L = 150, b = 100, electrode = E49, h = 8, Fz = 40,000, Mx = 5,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 750,000 mm3 750,000 +0.0000 % Pass
Unit second moment Iyy 562,500 mm3 562,500 +0.0000 % Pass
Unit polar moment J 1,312,500 mm3 1,312,500 +0.0000 % Pass
Total weld length 300 mm 300 +0.0000 % Pass
Largest resultant force per length 466.667 N/mm 466.67 +0.0007 % Pass
Required throat 1.5873 mm 1.587 -0.0190 % Pass
Required leg size 2.24478 mm 2.245 +0.0096 % Pass
Weld capacity per length 1,330.49 N/mm 1,330.49 -0.0002 % Pass
Factor of safety 2.85105 2.851 -0.0019 % Pass

Basis: Same pattern, out-of-plane force Fz/A + Mx y/Ixx. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Rectangular weld 120 x 80 mm: all six loads

Rectangular / Box Weld. Inputs: b = 120, d = 80, electrode = E70, h = 6, Fx = 20,000, Fy = 15,000, Fz = 12,000, Mx = 4,000,000, My = 3,000,000, Mz = 6,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 469,333 mm3 469,333 0.0000 % Pass
Unit second moment Iyy 864,000 mm3 864,000 +0.0000 % Pass
Unit polar moment J 1,333,333 mm3 1,333,333 0.0000 % Pass
Total weld length 400 mm 400 +0.0000 % Pass
Largest resultant force per length 665.19 N/mm 665.19 0.0000 % Pass
Required throat 2.29534 mm 2.295 -0.0149 % Pass
Required leg size 3.2461 mm 3.246 -0.0032 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 1.4787 1.479 +0.0206 % Pass

Basis: A = 2(b + d), Ixx = d^3/6 + b d^2/2, Iyy = b^3/6 + b^2 d/2, J = Ixx + Iyy. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Rectangular weld 120 x 80 mm: torsion with direct shear

Rectangular / Box Weld. Inputs: b = 120, d = 80, electrode = E55, h = 8, Fx = 30,000, Fy = 20,000, Mz = 9,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 469,333 mm3 469,333 0.0000 % Pass
Unit second moment Iyy 864,000 mm3 864,000 +0.0000 % Pass
Unit polar moment J 1,333,333 mm3 1,333,333 0.0000 % Pass
Total weld length 400 mm 400 +0.0000 % Pass
Largest resultant force per length 571.008 N/mm 571.01 +0.0004 % Pass
Required throat 1.73033 mm 1.73 -0.0189 % Pass
Required leg size 2.44705 mm 2.447 -0.0021 % Pass
Weld capacity per length 1,493.41 N/mm 1,493.41 +0.0000 % Pass
Factor of safety 2.61539 2.615 -0.0150 % Pass

Basis: Direct shear plus torsion at the corners. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Cross-shaped weld 150 x 100 mm: shear, bending and torsion

Cross-Shaped Weld. Inputs: b = 150, d = 100, electrode = E70, h = 6, Fx = 12,000, Fy = 9,000, Fz = 15,000, Mx = 2,000,000, My = 2,500,000, Mz = 3,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 83,333.3 mm3 83,333.3 0.0000 % Pass
Unit second moment Iyy 281,250 mm3 281,250 +0.0000 % Pass
Unit polar moment J 364,583 mm3 364,583 0.0000 % Pass
Total weld length 250 mm 250 +0.0000 % Pass
Largest resultant force per length 1,341.63 N/mm 1,341.63 +0.0000 % Pass
Required throat 4.6295 mm 4.63 +0.0107 % Pass
Required leg size 6.54711 mm 6.547 -0.0016 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 0.733148 0.733 -0.0202 % Pass

Basis: Two crossing lines: A = b + d, Ixx = d^3/12, Iyy = b^3/12. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Circular ring weld, 120 mm diameter: shear, bending and torsion

Circular Ring Weld. Inputs: D = 120, electrode = E70, h = 6, Fx = 18,000, Fy = 12,000, Fz = 25,000, Mx = 3,000,000, My = 2,000,000, Mz = 5,000,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 678,584 mm3 678,584 0.0000 % Pass
Unit second moment Iyy 678,584 mm3 678,584 0.0000 % Pass
Unit polar moment J 1,357,168 mm3 1,357,168 +0.0000 % Pass
Total weld length 376.991 mm 376.99 -0.0003 % Pass
Largest resultant force per length 459.674 N/mm 459.69 +0.0035 % Pass
Required throat 1.58618 mm 1.586 -0.0111 % Pass
Required leg size 2.24319 mm 2.243 -0.0086 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 2.13981 2.14 +0.0090 % Pass

Basis: A = pi D, Ixx = Iyy = pi D^3/8, J = pi D^3/4. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

L-shaped weld 120 x 80 mm: out-of-plane shear and bending

L-Shaped Weld (Angle). Inputs: b = 120, d = 80, electrode = E70, h = 6, Fz = 20,000, Mx = 2,500,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 119,467 mm3 119,467 +0.0000 % Pass
Unit second moment Iyy 316,800 mm3 316,800 +0.0000 % Pass
Unit polar moment J 436,267 mm3 436,267 +0.0000 % Pass
Total weld length 200 mm 200 +0.0000 % Pass
Largest resultant force per length 1,439.29 N/mm 1,439.29 +0.0003 % Pass
Required throat 4.96648 mm 4.966 -0.0097 % Pass
Required leg size 7.02366 mm 7.024 +0.0048 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 0.683404 0.683 -0.0591 % Pass

Basis: Two lines meeting at a corner: A = b + d; the centroid and second moments follow from the parallel-axis theorem. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

C-shaped weld (two verticals and a top line), 120 x 80 mm: shear, bending and torsion

C-Shaped (3-Side) Weld. Inputs: b = 120, d = 80, electrode = E70, h = 6, Fx = 15,000, Fy = 10,000, Fz = 18,000, Mx = 2,500,000, My = 2,000,000, Mz = 3,500,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 195,048 mm3 195,048 +0.0000 % Pass
Unit second moment Iyy 720,000 mm3 720,000 +0.0000 % Pass
Unit polar moment J 915,048 mm3 915,048 +0.0000 % Pass
Total weld length 280 mm 280 +0.0000 % Pass
Largest resultant force per length 891.323 N/mm 891.32 -0.0003 % Pass
Required throat 3.07565 mm 3.076 +0.0115 % Pass
Required leg size 4.34962 mm 4.35 +0.0087 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 1.10354 1.104 +0.0413 % Pass

Basis: Two verticals of length d and one horizontal b: A = 2d + b, the centroid lies b/2 across and d(d + b)/(2d + b) up from the bottom ends. The pattern is the set of lines drawn in the block's figure. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

T-shaped weld (flange and one web), 120 x 80 mm: shear, bending and torsion

T-Shaped Weld. Inputs: b = 120, d = 80, electrode = E70, h = 6, Fx = 15,000, Fy = 10,000, Fz = 18,000, Mx = 2,500,000, My = 2,000,000, Mz = 3,500,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 119,467 mm3 119,467 +0.0000 % Pass
Unit second moment Iyy 144,000 mm3 144,000 +0.0000 % Pass
Unit polar moment J 263,467 mm3 263,467 +0.0000 % Pass
Total weld length 200 mm 200 +0.0000 % Pass
Largest resultant force per length 1,491.22 N/mm 1,491.22 -0.0002 % Pass
Required throat 5.1457 mm 5.146 +0.0059 % Pass
Required leg size 7.27711 mm 7.277 -0.0015 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 0.659602 0.66 +0.0603 % Pass

Basis: A flange b and one web d: A = b + d, the centroid lies (b d + d^2/2)/(b + d) up from the bottom of the web. The pattern is the set of lines drawn in the block's figure. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

I-shaped weld (two flanges and one web), 120 x 80 mm: shear, bending and torsion

I / Built-Up Section Weld. Inputs: b = 120, d = 80, electrode = E70, h = 6, Fx = 15,000, Fy = 10,000, Fz = 18,000, Mx = 2,500,000, My = 2,000,000, Mz = 3,500,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 426,667 mm3 426,667 +0.0000 % Pass
Unit second moment Iyy 288,000 mm3 288,000 +0.0000 % Pass
Unit polar moment J 714,667 mm3 714,667 +0.0000 % Pass
Total weld length 320 mm 320 +0.0000 % Pass
Largest resultant force per length 792.562 N/mm 792.56 -0.0002 % Pass
Required throat 2.73486 mm 2.735 +0.0052 % Pass
Required leg size 3.86767 mm 3.868 +0.0084 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 1.24106 1.241 -0.0045 % Pass

Basis: Two flanges b and one web d: A = 2b + d, Ixx = b d^2/2 + d^3/12, Iyy = 2 b^3/12. The pattern is the set of lines drawn in the block's figure. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Channel-shaped weld (two flanges and one web), 120 x 80 mm: shear, bending and torsion

Channel-Shaped Weld. Inputs: b = 120, d = 80, electrode = E70, h = 6, Fx = 15,000, Fy = 10,000, Fz = 18,000, Mx = 2,500,000, My = 2,000,000, Mz = 3,500,000.

QuantityReferenceProgramDifferenceResult
Unit second moment Ixx 426,667 mm3 426,667 +0.0000 % Pass
Unit second moment Iyy 504,000 mm3 504,000 +0.0000 % Pass
Unit polar moment J 930,667 mm3 930,667 +0.0000 % Pass
Total weld length 320 mm 320 +0.0000 % Pass
Largest resultant force per length 669.226 N/mm 669.23 +0.0006 % Pass
Required throat 2.30927 mm 2.309 -0.0117 % Pass
Required leg size 3.2658 mm 3.266 +0.0061 % Pass
Weld capacity per length 983.614 N/mm 983.61 -0.0004 % Pass
Factor of safety 1.46978 1.47 +0.0151 % Pass

Basis: Two flanges b and one web d: A = 2b + d, the centroid lies b^2/(2b + d) from the web. The pattern is the set of lines drawn in the block's figure. Source: Blodgett, Design of Welded Structures, section 7.4 (properties of welds treated as lines); AS 4100 clause 9.7.3 (fillet weld capacity).

Process equipment: hydrocyclone (Plitt)

Hydrocyclone pressure drop, corrected cut size d50c, volume split, sharpness and the Lynch partition sizes by the Plitt (1976) model in the form printed on the SysCAD help page (equations 7 to 11; cm, litres per minute, volume percent). The reference writes the equations out again and solves the number of cyclones for a design pressure by bisection (the program uses the closed-form inverse) and d25c and d75c by bisection on the Lynch curve (the program inverts it algebraically). NOTE: the constants were read from one software help page; another source prints different cut-size constants and the original paper was not available, so this check confirms the program applies the printed equations, not that they suit a given cyclone (calibrate with the factors).

250 mm cyclones (inlet 0.2 Dc, vortex finder 0.3 Dc, apex 0.15 Dc, h = 1.5 Dc): 600 m3/h at 30 % w/w, SG 2.7, 8 cyclones

Hydrocyclone (Plitt). Inputs: feed_flow = 600, feed_solids_pct = 30, solids_sg = 2.7, number_of_cyclones = 8, cyclone_diameter = 250, inlet_diameter = 50, vortex_finder_diameter = 75, apex_diameter = 37.5, free_vortex_height = 375.

QuantityReferenceProgramDifferenceResult
Feed slurry density 1.23288 t/m3 1.233 +0.0100 % Pass
Feed solids by volume 13.6986 % v/v 13.7 +0.0100 % Pass
Number of cyclones 8 8 +0.0000 % Pass
Flow per cyclone 75 m3/h 75 +0.0000 % Pass
Pressure drop 395.787 kPa 395.8 +0.0032 % Pass
Pressure head 32.7245 m 32.72 -0.0138 % Pass
Corrected cut size 48.3976 um 48.4 +0.0049 % Pass
Feed volume to the underflow 7.58311 % 7.6 +0.2228 % Pass
Underflow flow 45.4986 m3/h 45.5 +0.0030 % Pass
Overflow flow 554.501 m3/h 554.5 -0.0002 % Pass
Sharpness m 1.95548 1.955 -0.0247 % Pass
Lynch alpha 2.54145 2.541 -0.0175 % Pass
d25c 30.2618 um 30.3 +0.1263 % Pass
d75c 68.2919 um 68.3 +0.0119 % Pass
Imperfection 0.392892 0.393 +0.0275 % Pass

Basis: d50c = F 50.5 Dc^0.46 Di^0.6 Do^1.21 exp(0.063 Cv) / (Du^0.71 h^0.38 Q^0.45 (rho_s - rho_l)^0.5); dP = Fp 1.88 Q^1.78 exp(0.0055 Cv) / (Dc^0.37 Di^0.94 h^0.28 (Du^2 + Do^2)^0.87); H = dP / (9.81 rho); S = Fs 1.9 (Du/Do)^3.31 h^0.54 (Du^2 + Do^2)^0.36 exp(0.0054 Cv) / (H^0.24 Dc^1.11), Rv = S / (S + 1); m = Fm 1.94 exp(-1.58 Rv) (Dc^2 h / Q_total)^0.15; alpha = 1.54 m - 0.47; Lynch curve inverted for d25c, d75c. Source: Plitt (1976) as printed on https://help.syscad.net/Cyclone (read); not checked against the original paper. Partly confirmed.

The same feed to a design pressure drop of 70 kPa: the number of cyclones is rounded up

Hydrocyclone (Plitt). Inputs: feed_flow = 600, feed_solids_pct = 30, solids_sg = 2.7, design_pressure = 70, cyclone_diameter = 250, inlet_diameter = 50, vortex_finder_diameter = 75, apex_diameter = 37.5, free_vortex_height = 375.

QuantityReferenceProgramDifferenceResult
Feed slurry density 1.23288 t/m3 1.233 +0.0100 % Pass
Feed solids by volume 13.6986 % v/v 13.7 +0.0100 % Pass
Number of cyclones 22 22 +0.0000 % Pass
Flow per cyclone 27.2727 m3/h 27.27 -0.0100 % Pass
Pressure drop 65.3807 kPa 65.4 +0.0295 % Pass
Pressure head 5.40581 m 5.41 +0.0775 % Pass
Corrected cut size 76.2998 um 76.3 +0.0002 % Pass
Feed volume to the underflow 11.2223 % 11.2 -0.1989 % Pass
Underflow flow 67.3339 m3/h 67.33 -0.0058 % Pass
Overflow flow 532.666 m3/h 532.67 +0.0007 % Pass
Sharpness m 1.84622 1.846 -0.0117 % Pass
Lynch alpha 2.37317 2.373 -0.0073 % Pass
d25c 46.4729 um 46.5 +0.0583 % Pass
d75c 109.559 um 109.6 +0.0372 % Pass
Imperfection 0.413411 0.413 -0.0994 % Pass

Basis: d50c = F 50.5 Dc^0.46 Di^0.6 Do^1.21 exp(0.063 Cv) / (Du^0.71 h^0.38 Q^0.45 (rho_s - rho_l)^0.5); dP = Fp 1.88 Q^1.78 exp(0.0055 Cv) / (Dc^0.37 Di^0.94 h^0.28 (Du^2 + Do^2)^0.87); H = dP / (9.81 rho); S = Fs 1.9 (Du/Do)^3.31 h^0.54 (Du^2 + Do^2)^0.36 exp(0.0054 Cv) / (H^0.24 Dc^1.11), Rv = S / (S + 1); m = Fm 1.94 exp(-1.58 Rv) (Dc^2 h / Q_total)^0.15; alpha = 1.54 m - 0.47; Lynch curve inverted for d25c, d75c. Source: Plitt (1976) as printed on https://help.syscad.net/Cyclone (read); not checked against the original paper. Partly confirmed.

Liquid density 1.02, calibration factors 1.15 (d50), 0.95 (pressure), 1.1 (split), 0.9 (sharpness), 10 cyclones, a 20 % w/w feed of SG 3.2

Hydrocyclone (Plitt). Inputs: feed_flow = 450, feed_solids_pct = 20, solids_sg = 3.2, liquid_density = 1.02, number_of_cyclones = 10, d50_factor = 1.15, pressure_factor = 0.95, split_factor = 1.1, sharpness_factor = 0.9, cyclone_diameter = 250, inlet_diameter = 50, vortex_finder_diameter = 75, apex_diameter = 37.5, free_vortex_height = 375.

QuantityReferenceProgramDifferenceResult
Feed slurry density 1.1809 t/m3 1.181 +0.0087 % Pass
Feed solids by volume 7.38061 % v/v 7.38 -0.0082 % Pass
Number of cyclones 10 10 +0.0000 % Pass
Flow per cyclone 45 m3/h 45 +0.0000 % Pass
Pressure drop 146.286 kPa 146.3 +0.0094 % Pass
Pressure head 12.6276 m 12.63 +0.0187 % Pass
Corrected cut size 41.5418 um 41.5 -0.1006 % Pass
Feed volume to the underflow 9.87975 % 9.9 +0.2049 % Pass
Underflow flow 44.4589 m3/h 44.46 +0.0025 % Pass
Overflow flow 405.541 m3/h 405.54 -0.0003 % Pass
Sharpness m 1.77206 1.772 -0.0034 % Pass
Lynch alpha 2.25897 2.259 +0.0013 % Pass
d25c 24.8276 um 24.8 -0.1113 % Pass
d75c 60.4175 um 60.4 -0.0290 % Pass
Imperfection 0.428363 0.428 -0.0847 % Pass

Basis: d50c = F 50.5 Dc^0.46 Di^0.6 Do^1.21 exp(0.063 Cv) / (Du^0.71 h^0.38 Q^0.45 (rho_s - rho_l)^0.5); dP = Fp 1.88 Q^1.78 exp(0.0055 Cv) / (Dc^0.37 Di^0.94 h^0.28 (Du^2 + Do^2)^0.87); H = dP / (9.81 rho); S = Fs 1.9 (Du/Do)^3.31 h^0.54 (Du^2 + Do^2)^0.36 exp(0.0054 Cv) / (H^0.24 Dc^1.11), Rv = S / (S + 1); m = Fm 1.94 exp(-1.58 Rv) (Dc^2 h / Q_total)^0.15; alpha = 1.54 m - 0.47; Lynch curve inverted for d25c, d75c. Source: Plitt (1976) as printed on https://help.syscad.net/Cyclone (read); not checked against the original paper. Partly confirmed.

Process equipment: filter area

Filter area from a specific solids rate (kg of dry cake per m2 per hour) and / or the constant-pressure cake filtration equation t = a v^2 + b v, a = mu alpha c / (2 dP), b = mu Rm / dP (Ruth; v is the filtrate per m2), with the cycle = filtration time + other times; the largest area governs. The reference does NOT use the closed-form quadratic: it integrates dv/dt = dP / (mu (alpha c v + Rm)) numerically (Runge-Kutta) for the same inputs (and the exact square-root solution when the medium resistance is zero). The cake resistance, medium resistance and specific rate are inputs from tests or the vendor. The equations were read from lecture notes in search extracts (partly confirmed): this check confirms the program solves them correctly, not that the equation suits a given slurry.

Cake filtration only: 10 t/h, 400 kPa, c = 50 kg/m3, alpha = 1e11 m/kg, Rm = 1e10 1/m, 20 min filtration + 15 min other

Filter Area. Inputs: solids_rate = 10, solids_per_filtrate = 50, pressure_drop = 400, viscosity = 1, cake_resistance = 100,000,000,000, medium_resistance = 10,000,000,000, filtration_time = 20, other_time = 15, cake_bulk_density = 700.

QuantityReferenceProgramDifferenceResult
Filtrate per m2 per cycle 436.183 L/m2 436.18 -0.0006 % Pass
Dry cake per m2 per cycle 21.8091 kg/m2 21.81 +0.0040 % Pass
Cycles per hour 1.71429 1/h 1.714 -0.0167 % Pass
Specific solids rate from the cake equation 37.3871 kg/(m2.h) 37.4 +0.0346 % Pass
Area from the cake filtration equation 267.472 m2 267.5 +0.0104 % Pass
Cake thickness 31.1559 mm 31.2 +0.1415 % Pass
Design area 267.472 m2 267.5 +0.0104 % Pass
Area of each filter 267.472 m2 267.5 +0.0104 % Pass
Filtrate flow 200 m3/h 200 +0.0000 % Pass

Basis: t = a v^2 + b v with a = mu alpha c / (2 dP), b = mu Rm / dP; here v is found by integrating dv/dt = dP / (mu (alpha c v + Rm)); cake per m2 per cycle = c v; cycles/h = 3600 / (cycle s); area = solids kg/h / (c v x cycles/h), or solids kg/h / specific rate; the largest governs, x (1 + margin). Source: Constant-pressure cake filtration (Ruth): NPTEL Module 10 Filtration, lecture 36; QMUL lecture notes (see the block's sources). Partly confirmed.

Specific rate only: 25 t/h at 40 kg/(m2.h), 10 % margin, two filters

Filter Area. Inputs: solids_rate = 25, specific_rate = 40, design_margin = 10, number_of_units = 2.

QuantityReferenceProgramDifferenceResult
Area from the specific solids rate 625 m2 625 +0.0000 % Pass
Design area 687.5 m2 687.5 +0.0000 % Pass
Area of each filter 343.75 m2 343.8 +0.0145 % Pass

Basis: t = a v^2 + b v with a = mu alpha c / (2 dP), b = mu Rm / dP; here v is found by integrating dv/dt = dP / (mu (alpha c v + Rm)); cake per m2 per cycle = c v; cycles/h = 3600 / (cycle s); area = solids kg/h / (c v x cycles/h), or solids kg/h / specific rate; the largest governs, x (1 + margin). Source: Constant-pressure cake filtration (Ruth): NPTEL Module 10 Filtration, lecture 36; QMUL lecture notes (see the block's sources). Partly confirmed.

Both bases: the specific rate of 35 kg/(m2.h) asks for more area than the cake equation

Filter Area. Inputs: solids_rate = 10, solids_per_filtrate = 50, pressure_drop = 400, viscosity = 1, cake_resistance = 100,000,000,000, medium_resistance = 10,000,000,000, filtration_time = 20, other_time = 15, cake_bulk_density = 700, specific_rate = 35.

QuantityReferenceProgramDifferenceResult
Area from the specific solids rate 285.714 m2 285.7 -0.0050 % Pass
Filtrate per m2 per cycle 436.183 L/m2 436.18 -0.0006 % Pass
Dry cake per m2 per cycle 21.8091 kg/m2 21.81 +0.0040 % Pass
Cycles per hour 1.71429 1/h 1.714 -0.0167 % Pass
Specific solids rate from the cake equation 37.3871 kg/(m2.h) 37.4 +0.0346 % Pass
Area from the cake filtration equation 267.472 m2 267.5 +0.0104 % Pass
Cake thickness 31.1559 mm 31.2 +0.1415 % Pass
Design area 285.714 m2 285.7 -0.0050 % Pass
Area of each filter 285.714 m2 285.7 -0.0050 % Pass
Filtrate flow 213.64 m3/h 213.6 -0.0189 % Pass

Basis: t = a v^2 + b v with a = mu alpha c / (2 dP), b = mu Rm / dP; here v is found by integrating dv/dt = dP / (mu (alpha c v + Rm)); cake per m2 per cycle = c v; cycles/h = 3600 / (cycle s); area = solids kg/h / (c v x cycles/h), or solids kg/h / specific rate; the largest governs, x (1 + margin). Source: Constant-pressure cake filtration (Ruth): NPTEL Module 10 Filtration, lecture 36; QMUL lecture notes (see the block's sources). Partly confirmed.

No medium resistance (the exact square-root solution): 5 t/h, 600 kPa, c = 120 kg/m3, mu 1.2 mPa.s, alpha = 5e10, 10 min + 20 min

Filter Area. Inputs: solids_rate = 5, solids_per_filtrate = 120, pressure_drop = 600, viscosity = 1.2, cake_resistance = 50,000,000,000, medium_resistance = 0, filtration_time = 10, other_time = 20.

QuantityReferenceProgramDifferenceResult
Filtrate per m2 per cycle 316.228 L/m2 316.23 +0.0007 % Pass
Dry cake per m2 per cycle 37.9473 kg/m2 37.95 +0.0070 % Pass
Cycles per hour 2 1/h 2 +0.0000 % Pass
Specific solids rate from the cake equation 75.8947 kg/(m2.h) 75.9 +0.0070 % Pass
Area from the cake filtration equation 65.8808 m2 65.9 +0.0292 % Pass
Design area 65.8808 m2 65.9 +0.0292 % Pass
Area of each filter 65.8808 m2 65.9 +0.0292 % Pass
Filtrate flow 41.6667 m3/h 41.7 +0.0800 % Pass

Basis: t = a v^2 + b v with a = mu alpha c / (2 dP), b = mu Rm / dP; here v is found by integrating dv/dt = dP / (mu (alpha c v + Rm)); cake per m2 per cycle = c v; cycles/h = 3600 / (cycle s); area = solids kg/h / (c v x cycles/h), or solids kg/h / specific rate; the largest governs, x (1 + margin). Source: Constant-pressure cake filtration (Ruth): NPTEL Module 10 Filtration, lecture 36; QMUL lecture notes (see the block's sources). Partly confirmed.

Process equipment: mill power (Bond)

Ball and rod mill power by Bond's third theory, W = 10 Wi (1 / sqrt(P80) - 1 / sqrt(F80)) kWh/t, times Rowland's efficiency factors EF1 (dry), EF3 (mill diameter), EF4 (oversize feed), EF5 (fine grinding) and EF7 (low reduction ratio), and the power at the pinion = W x throughput. The reference writes the published equations out directly (plain Python). The work index and the factors read from tables (EF2, EF6, EF8) are inputs. NOTE: the factor equations are those of Rowland as published in Wills' Mineral Processing Technology; this check confirms the program applies them as written, it is not an independent validation against a published worked example.

Bond equation only: Wi 13.6, F80 10000 um, P80 100 um, 120 t/h, no factors (W = 12.24 kWh/t)

Mill Power (Bond). Inputs: throughput = 120, work_index = 13.6, feed_f80 = 10,000, product_p80 = 100, efficiency_factors = none.

QuantityReferenceProgramDifferenceResult
Reduction ratio 100 100 +0.0000 % Pass
Specific energy, Bond equation 12.24 kWh/t 12.24 0.0000 % Pass
Optimum feed size F0 3,910.77 um 3,911 +0.0059 % Pass
Total efficiency factor 1 1 +0.0000 % Pass
Specific energy at the pinion 12.24 kWh/t 12.24 0.0000 % Pass
Mill power at the pinion 1,468.8 kW 1,468.8 0.0000 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Wet ball mill 4.2 m diameter (EF3 = 0.914), oversize feed (EF4), Wi 14.5, F80 12000 um, P80 106 um

Mill Power (Bond). Inputs: throughput = 250, work_index = 14.5, feed_f80 = 12,000, product_p80 = 106, mill_diameter = 4.2.

QuantityReferenceProgramDifferenceResult
Reduction ratio 113.208 113.21 +0.0022 % Pass
Specific energy, Bond equation 12.76 kWh/t 12.76 +0.0001 % Pass
Optimum feed size F0 3,787.46 um 3,787 -0.0121 % Pass
EF1 1 1 +0.0000 % Pass
EF3 0.914 0.914 +0.0000 % Pass
EF4 1.14365 1.1437 +0.0041 % Pass
Total efficiency factor 1.0453 1.0453 +0.0001 % Pass
Specific energy at the pinion 13.338 kWh/t 13.338 +0.0000 % Pass
Mill power at the pinion 3,334.5 kW 3,334.5 +0.0000 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Fine grinding to 45 um in a 3.0 m wet ball mill (EF5, EF3 from the diameter), Wi 16, F80 2000 um

Mill Power (Bond). Inputs: throughput = 60, work_index = 16, feed_f80 = 2,000, product_p80 = 45, mill_diameter = 3.

QuantityReferenceProgramDifferenceResult
Reduction ratio 44.4444 44.44 -0.0100 % Pass
Specific energy, Bond equation 20.2737 kWh/t 20.274 +0.0016 % Pass
Optimum feed size F0 3,605.55 um 3,606 +0.0124 % Pass
EF1 1 1 +0.0000 % Pass
EF3 0.959519 0.9595 -0.0020 % Pass
EF4 1 1 +0.0000 % Pass
EF5 1.07327 1.0733 +0.0032 % Pass
Total efficiency factor 1.02982 1.0298 -0.0018 % Pass
Specific energy at the pinion 20.8782 kWh/t 20.878 -0.0011 % Pass
Mill power at the pinion 1,252.69 kW 1,252.7 +0.0005 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Regrind with a low reduction ratio (EF7): F80 600 um, P80 150 um, Wi 12

Mill Power (Bond). Inputs: throughput = 40, work_index = 12, feed_f80 = 600, product_p80 = 150.

QuantityReferenceProgramDifferenceResult
Reduction ratio 4 4 +0.0000 % Pass
Specific energy, Bond equation 4.89898 kWh/t 4.899 +0.0004 % Pass
Optimum feed size F0 4,163.33 um 4,163 -0.0080 % Pass
EF1 1 1 +0.0000 % Pass
EF4 1 1 +0.0000 % Pass
EF7 1.04906 1.0491 +0.0041 % Pass
Total efficiency factor 1.04906 1.0491 +0.0041 % Pass
Specific energy at the pinion 5.13931 kWh/t 5.139 -0.0060 % Pass
Mill power at the pinion 205.572 kW 205.6 +0.0135 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Dry grinding (EF1 = 1.3), 3.0 m, and an open-circuit factor of 1.2 as other factors

Mill Power (Bond). Inputs: throughput = 35, work_index = 11, feed_f80 = 3,000, product_p80 = 200, grinding = dry, mill_diameter = 3, other_factors = 1.2.

QuantityReferenceProgramDifferenceResult
Reduction ratio 15 15 +0.0000 % Pass
Specific energy, Bond equation 5.76986 kWh/t 5.77 +0.0025 % Pass
Optimum feed size F0 4,348.46 um 4,348 -0.0105 % Pass
EF1 1.3 1.3 +0.0000 % Pass
EF3 0.959519 0.9595 -0.0020 % Pass
EF4 1 1 +0.0000 % Pass
Total efficiency factor 1.49685 1.4969 +0.0033 % Pass
Specific energy at the pinion 8.63661 kWh/t 8.637 +0.0045 % Pass
Mill power at the pinion 302.281 kW 302.3 +0.0061 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Rod mill, Wi 12, F80 25000 um to P80 1500 um (the rod mill optimum feed size 16000 sqrt(13/Wi) applies)

Mill Power (Bond). Inputs: throughput = 80, work_index = 12, feed_f80 = 25,000, product_p80 = 1,500, mill_type = rod, mill_diameter = 2.8.

QuantityReferenceProgramDifferenceResult
Reduction ratio 16.6667 16.67 +0.0200 % Pass
Specific energy, Bond equation 2.33944 kWh/t 2.339 -0.0188 % Pass
Optimum feed size F0 16,653.3 um 16,653 -0.0020 % Pass
EF1 1 1 +0.0000 % Pass
EF3 0.972851 0.9729 +0.0050 % Pass
EF4 1.15036 1.1504 +0.0034 % Pass
Total efficiency factor 1.11913 1.1191 -0.0026 % Pass
Specific energy at the pinion 2.61814 kWh/t 2.618 -0.0052 % Pass
Mill power at the pinion 209.451 kW 209.5 +0.0234 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Open circuit wet ball mill, 80 % of the product passing the control size (EF2 = 1.20)

Mill Power (Bond). Inputs: throughput = 90, work_index = 13, feed_f80 = 8,000, product_p80 = 150, mill_diameter = 3.4, circuit = open, open_circuit_passing = 80.

QuantityReferenceProgramDifferenceResult
Reduction ratio 53.3333 53.33 -0.0063 % Pass
Specific energy, Bond equation 9.16101 kWh/t 9.161 -0.0001 % Pass
Optimum feed size F0 4,000 um 4,000 +0.0000 % Pass
EF1 1 1 +0.0000 % Pass
EF2 1.2 1.2 +0.0000 % Pass
EF3 0.935798 0.9358 +0.0002 % Pass
EF4 1.1125 1.1125 +0.0000 % Pass
Total efficiency factor 1.24929 1.2493 +0.0008 % Pass
Specific energy at the pinion 11.4448 kWh/t 11.445 +0.0021 % Pass
Mill power at the pinion 1,030.03 kW 1,030 -0.0028 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Open circuit, 85 % passing: EF2 is read between the 80 % and 90 % points (1.30)

Mill Power (Bond). Inputs: throughput = 90, work_index = 13, feed_f80 = 8,000, product_p80 = 150, mill_diameter = 3.4, circuit = open, open_circuit_passing = 85.

QuantityReferenceProgramDifferenceResult
Reduction ratio 53.3333 53.33 -0.0063 % Pass
Specific energy, Bond equation 9.16101 kWh/t 9.161 -0.0001 % Pass
Optimum feed size F0 4,000 um 4,000 +0.0000 % Pass
EF1 1 1 +0.0000 % Pass
EF2 1.3 1.3 +0.0000 % Pass
EF3 0.935798 0.9358 +0.0002 % Pass
EF4 1.1125 1.1125 +0.0000 % Pass
Total efficiency factor 1.3534 1.3534 +0.0001 % Pass
Specific energy at the pinion 12.3985 kWh/t 12.398 -0.0040 % Pass
Mill power at the pinion 1,115.86 kW 1,115.9 +0.0032 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Rod mill 2.8 m diameter, 4.2 m long: EF6 from the reduction ratio against the optimum 8 + 5 L/D

Mill Power (Bond). Inputs: throughput = 80, work_index = 12, feed_f80 = 25,000, product_p80 = 1,500, mill_type = rod, mill_diameter = 2.8, rod_length = 4.2.

QuantityReferenceProgramDifferenceResult
Reduction ratio 16.6667 16.67 +0.0200 % Pass
Specific energy, Bond equation 2.33944 kWh/t 2.339 -0.0188 % Pass
Optimum feed size F0 16,653.3 um 16,653 -0.0020 % Pass
EF1 1 1 +0.0000 % Pass
EF6 1.00907 1.0091 +0.0026 % Pass
EF3 0.972851 0.9729 +0.0050 % Pass
EF4 1.15036 1.1504 +0.0034 % Pass
Total efficiency factor 1.12928 1.1293 +0.0014 % Pass
Specific energy at the pinion 2.64189 kWh/t 2.642 +0.0040 % Pass
Mill power at the pinion 211.351 kW 211.4 +0.0230 % Pass

Basis: W = 10 Wi (1/sqrt(P80) - 1/sqrt(F80)); F0 = 4000 sqrt(13/Wi) (rod mill 16000 sqrt(13/Wi)); EF1 = 1.3 dry; EF3 = (2.44/D)^0.2 (0.914 above 3.81 m); EF4 = (Rr + (Wi - 7)(F80 - F0)/F0)/Rr when F80 > F0; EF5 = (P80 + 10.3)/(1.145 P80) when P80 < 75 um (ball); EF7 = (2(Rr - 1.35) + 0.26)/(2(Rr - 1.35)) when Rr < 6 (ball); power = W x EF x t/h. Source: Bond's third theory of comminution; Rowland's efficiency factors as given in Wills, Mineral Processing Technology (ball and rod mill power).

Process equipment: dryer heat balance

The heat and mass balance of a convective dryer (hot gas): the water evaporated from the feed and product moistures, the heat to the solids, the water left in the product and the evaporation (latent heat from the Engineering ToolBox table, linear between its points; liquid water 4.186, vapour 1.88 kJ/(kg.K), neither confirmed by a source), the heat input with the loss, the specific heat consumption, the hot gas flow from its temperature drop and the fuel. The reference works per kg of dry solids and scales it, a different route from the program's stream-by-stream kW. The solids specific heat, the temperatures and the losses are inputs.

Rotary dryer: 50 t/h at 12 % to 1 % moisture, solids 0.9 kJ/(kg.K), product 80 C, gas 450 to 120 C, 10 % loss, fuel 42 MJ/kg at 85 %

Dryer Heat Balance. Inputs: feed_rate = 50, feed_moisture = 12, product_moisture = 1, solids_cp = 0.9, feed_temperature = 20, product_temperature = 80, evaporation_temperature = 70, gas_inlet_temperature = 450, gas_outlet_temperature = 120, gas_cp = 1.05, heat_loss = 10, fuel_lhv = 42, burner_efficiency = 85.

QuantityReferenceProgramDifferenceResult
Dry solids 44 t/h 44 +0.0000 % Pass
Product 44.4444 t/h 44.444 -0.0010 % Pass
Water evaporated 5.55556 t/h 5.556 +0.0080 % Pass
Heat to the solids 660 kW 660 +0.0000 % Pass
Heat to the water left in the product 31.0074 kW 31 -0.0239 % Pass
Heat to evaporate and superheat the water 4,068.36 kW 4,068.4 +0.0009 % Pass
Useful heat 4,759.37 kW 4,759.4 +0.0006 % Pass
Heat input 5,288.19 kW 5,288.2 +0.0002 % Pass
Specific heat consumption 3,426.75 kJ/kg 3,427 +0.0074 % Pass
Evaporation efficiency 68.0821 % 68.1 +0.0264 % Pass
Hot gas flow 54,942.2 kg/h 54,942 -0.0004 % Pass
Humidity rise of the gas 0.101116 kg/kg 0.1011 -0.0161 % Pass
Fuel rate 533.263 kg/h 533.3 +0.0070 % Pass

Basis: Ms = F (1 - w1); X = w / (1 - w); water = Ms (X1 - X2); per kg dry solids q = (cps + X2 cpw)(Tp - Tf) + (X1 - X2)(cpw (Tev - Tf) + lambda + cpv max(0, Texh - Tev)), lambda interpolated in the table; heat input = Ms q / (1 - loss); gas = heat input / (cp (Tin - Tout)); efficiency = water x lambda / heat input; fuel = heat input / (LHV x efficiency). Source: Latent heat: engineeringtoolbox.com/water-properties-d_1573.html (read). The convective dryer heat and mass balance is a textbook energy balance (Mujumdar; Perry's), not checked against a page.

Exhaust above the evaporation temperature: the vapour is superheated (evaporation at 100 C, exhaust 140 C), no loss, defaults for feed temperature and gas specific heat

Dryer Heat Balance. Inputs: feed_rate = 20, feed_moisture = 25, product_moisture = 5, solids_cp = 1, product_temperature = 90, gas_inlet_temperature = 300, gas_outlet_temperature = 140.

QuantityReferenceProgramDifferenceResult
Dry solids 15 t/h 15 +0.0000 % Pass
Product 15.7895 t/h 15.789 -0.0030 % Pass
Water evaporated 4.21053 t/h 4.211 +0.0113 % Pass
Heat to the solids 291.667 kW 291.7 +0.0114 % Pass
Heat to the water left in the product 64.2588 kW 64.3 +0.0642 % Pass
Heat to evaporate and superheat the water 3,118.69 kW 3,118.7 +0.0003 % Pass
Useful heat 3,474.62 kW 3,474.6 -0.0004 % Pass
Heat input 3,474.62 kW 3,474.6 -0.0004 % Pass
Specific heat consumption 2,970.8 kJ/kg 2,971 +0.0069 % Pass
Evaporation efficiency 75.9527 % 76 +0.0623 % Pass
Hot gas flow 74,456 kg/h 74,456 -0.0001 % Pass
Humidity rise of the gas 0.0565505 kg/kg 0.0566 +0.0875 % Pass

Basis: Ms = F (1 - w1); X = w / (1 - w); water = Ms (X1 - X2); per kg dry solids q = (cps + X2 cpw)(Tp - Tf) + (X1 - X2)(cpw (Tev - Tf) + lambda + cpv max(0, Texh - Tev)), lambda interpolated in the table; heat input = Ms q / (1 - loss); gas = heat input / (cp (Tin - Tout)); efficiency = water x lambda / heat input; fuel = heat input / (LHV x efficiency). Source: Latent heat: engineeringtoolbox.com/water-properties-d_1573.html (read). The convective dryer heat and mass balance is a textbook energy balance (Mujumdar; Perry's), not checked against a page.

Wet bulb evaporation at 60 C with an exhaust of 55 C: no superheat term

Dryer Heat Balance. Inputs: feed_rate = 8, feed_moisture = 40, product_moisture = 10, solids_cp = 1.2, feed_temperature = 15, product_temperature = 55, evaporation_temperature = 60, gas_inlet_temperature = 160, gas_outlet_temperature = 55, gas_cp = 1.1, heat_loss = 5.

QuantityReferenceProgramDifferenceResult
Dry solids 4.8 t/h 4.8 +0.0000 % Pass
Product 5.33333 t/h 5.333 -0.0062 % Pass
Water evaporated 2.66667 t/h 2.667 +0.0125 % Pass
Heat to the solids 64 kW 64 +0.0000 % Pass
Heat to the water left in the product 24.8059 kW 24.8 -0.0239 % Pass
Heat to evaporate and superheat the water 1,885.98 kW 1,886 +0.0012 % Pass
Useful heat 1,974.78 kW 1,974.8 +0.0008 % Pass
Heat input 2,078.72 kW 2,078.7 -0.0009 % Pass
Specific heat consumption 2,806.27 kJ/kg 2,806 -0.0097 % Pass
Evaporation efficiency 84.0154 % 84 -0.0183 % Pass
Hot gas flow 64,791.3 kg/h 64,791 -0.0004 % Pass
Humidity rise of the gas 0.0411578 kg/kg 0.0412 +0.1025 % Pass

Basis: Ms = F (1 - w1); X = w / (1 - w); water = Ms (X1 - X2); per kg dry solids q = (cps + X2 cpw)(Tp - Tf) + (X1 - X2)(cpw (Tev - Tf) + lambda + cpv max(0, Texh - Tev)), lambda interpolated in the table; heat input = Ms q / (1 - loss); gas = heat input / (cp (Tin - Tout)); efficiency = water x lambda / heat input; fuel = heat input / (LHV x efficiency). Source: Latent heat: engineeringtoolbox.com/water-properties-d_1573.html (read). The convective dryer heat and mass balance is a textbook energy balance (Mujumdar; Perry's), not checked against a page.

Process equipment: thickener sizing

The mass balance across a thickener and the area it needs from a unit area, a solids flux and / or an overflow rise-rate limit (the largest governs). The reference evaluates the slurry density formula and the closed forms separately (plain Python); water is 1.000 t/m3 and the program's own volume-additive balance must agree with the mass / density route. The unit area, flux and rise rate are the person's inputs (settling tests or the vendor): the check is the arithmetic, not a choice of those values.

Unit area 0.3 m2/(t/d), 100 t/h at 20 % to 60 %, all solids to the underflow

Thickener Sizing. Inputs: feed_solids = 100, feed_solids_pct = 20, solids_sg = 2.7, underflow_solids_pct = 60, solids_to_underflow = 100, unit_area = 0.3.

QuantityReferenceProgramDifferenceResult
Feed solids 2,400 t/d 2,400 +0.0000 % Pass
Feed slurry flow 437.037 m3/h 437.04 +0.0007 % Pass
Underflow slurry flow 103.704 m3/h 103.7 -0.0036 % Pass
Overflow flow 333.333 m3/h 333.33 -0.0010 % Pass
Overflow solids concentration 0 % w/w 0 0 Pass
Design area 720 m2 720 +0.0000 % Pass
Diameter of each thickener 30.2776 m 30.28 +0.0080 % Pass
Unit area provided 0.3 m2/(t/d) 0.3 +0.0000 % Pass
Solids flux provided 0.138889 t/(m2.h) 0.1389 +0.0080 % Pass
Rise rate provided 0.462963 m/h 0.463 +0.0080 % Pass
Area from the unit area 720 m2 720 +0.0000 % Pass

Basis: rho = 1 / (C/SG + (1 - C)), Q = mass / rho for the feed, underflow and overflow; underflow solids = feed solids x recovery; overflow = feed - underflow (mass); A = unit area x t/d, or M / flux, or Q_overflow / rise rate (the largest, x (1 + margin)); D = sqrt(4 A / (pi N)); V = A x depth; retention = V / Q_feed. Source: Thickener sizing by the unit area and solids flux methods (Coe and Clevenger; Mular and Bhappu, Mineral Processing Plant Design); water 1.000 t/m3.

Solids flux 0.9 t/(m2.h), 98 % to the underflow, 10 % margin, two thickeners

Thickener Sizing. Inputs: feed_solids = 250, feed_solids_pct = 15, solids_sg = 2.9, underflow_solids_pct = 55, solids_to_underflow = 98, solids_flux = 0.9, design_margin = 10, number_of_units = 2.

QuantityReferenceProgramDifferenceResult
Feed solids 6,000 t/d 6,000 +0.0000 % Pass
Feed slurry flow 1,502.87 m3/h 1,502.87 -0.0002 % Pass
Underflow slurry flow 284.937 m3/h 284.94 +0.0009 % Pass
Overflow flow 1,217.94 m3/h 1,217.94 +0.0003 % Pass
Overflow solids concentration 0.409429 % w/w 0.409 -0.1048 % Pass
Design area 305.556 m2 305.6 +0.0145 % Pass
Diameter of each thickener 13.9471 m 13.95 +0.0205 % Pass
Unit area provided 0.0509259 m2/(t/d) 0.0509 -0.0509 % Pass
Solids flux provided 0.818182 t/(m2.h) 0.8182 +0.0022 % Pass
Rise rate provided 3.98597 m/h 3.986 +0.0007 % Pass
Area from the solids flux 277.778 m2 277.8 +0.0080 % Pass

Basis: rho = 1 / (C/SG + (1 - C)), Q = mass / rho for the feed, underflow and overflow; underflow solids = feed solids x recovery; overflow = feed - underflow (mass); A = unit area x t/d, or M / flux, or Q_overflow / rise rate (the largest, x (1 + margin)); D = sqrt(4 A / (pi N)); V = A x depth; retention = V / Q_feed. Source: Thickener sizing by the unit area and solids flux methods (Coe and Clevenger; Mular and Bhappu, Mineral Processing Plant Design); water 1.000 t/m3.

A dilute feed (5 %): the rise rate of 2.0 m/h governs over a small unit area

Thickener Sizing. Inputs: feed_solids = 40, feed_solids_pct = 5, solids_sg = 2.65, underflow_solids_pct = 45, solids_to_underflow = 97, unit_area = 0.05, max_rise_rate = 2.

QuantityReferenceProgramDifferenceResult
Feed solids 960 t/d 960 +0.0000 % Pass
Feed slurry flow 775.094 m3/h 775.09 -0.0006 % Pass
Underflow slurry flow 62.0637 m3/h 62.06 -0.0060 % Pass
Overflow flow 713.031 m3/h 713.03 -0.0001 % Pass
Overflow solids concentration 0.16812 % w/w 0.168 -0.0711 % Pass
Design area 356.515 m2 356.5 -0.0043 % Pass
Diameter of each thickener 21.3056 m 21.31 +0.0206 % Pass
Unit area provided 0.37137 m2/(t/d) 0.3714 +0.0080 % Pass
Solids flux provided 0.112197 t/(m2.h) 0.1122 +0.0025 % Pass
Rise rate provided 2 m/h 2 +0.0000 % Pass
Area from the unit area 48 m2 48 +0.0000 % Pass
Area from the rise rate 356.515 m2 356.5 -0.0043 % Pass

Basis: rho = 1 / (C/SG + (1 - C)), Q = mass / rho for the feed, underflow and overflow; underflow solids = feed solids x recovery; overflow = feed - underflow (mass); A = unit area x t/d, or M / flux, or Q_overflow / rise rate (the largest, x (1 + margin)); D = sqrt(4 A / (pi N)); V = A x depth; retention = V / Q_feed. Source: Thickener sizing by the unit area and solids flux methods (Coe and Clevenger; Mular and Bhappu, Mineral Processing Plant Design); water 1.000 t/m3.

All three bases given, 3.5 m side wall: the largest area governs and the volume and retention follow

Thickener Sizing. Inputs: feed_solids = 180, feed_solids_pct = 10, solids_sg = 3.4, underflow_solids_pct = 65, solids_to_underflow = 99, unit_area = 0.12, solids_flux = 1.5, max_rise_rate = 1.6, design_margin = 5, number_of_units = 1, side_wall_depth = 3.5.

QuantityReferenceProgramDifferenceResult
Feed solids 4,320 t/d 4,320 +0.0000 % Pass
Feed slurry flow 1,672.94 m3/h 1,672.94 -0.0001 % Pass
Underflow slurry flow 148.366 m3/h 148.37 +0.0030 % Pass
Overflow flow 1,524.58 m3/h 1,524.58 +0.0003 % Pass
Overflow solids concentration 0.117967 % w/w 0.118 +0.0277 % Pass
Design area 1,000.5 m2 1,000.5 -0.0003 % Pass
Diameter of each thickener 35.6915 m 35.69 -0.0041 % Pass
Unit area provided 0.231598 m2/(t/d) 0.2316 +0.0009 % Pass
Solids flux provided 0.17991 t/(m2.h) 0.1799 -0.0053 % Pass
Rise rate provided 1.52381 m/h 1.524 +0.0125 % Pass
Area from the unit area 518.4 m2 518.4 +0.0000 % Pass
Area from the solids flux 120 m2 120 +0.0000 % Pass
Area from the rise rate 952.86 m2 952.9 +0.0042 % Pass
Volume 3,501.76 m3 3,501.8 +0.0012 % Pass
Feed retention time 2.09318 h 2.09 -0.1517 % Pass

Basis: rho = 1 / (C/SG + (1 - C)), Q = mass / rho for the feed, underflow and overflow; underflow solids = feed solids x recovery; overflow = feed - underflow (mass); A = unit area x t/d, or M / flux, or Q_overflow / rise rate (the largest, x (1 + margin)); D = sqrt(4 A / (pi N)); V = A x depth; retention = V / Q_feed. Source: Thickener sizing by the unit area and solids flux methods (Coe and Clevenger; Mular and Bhappu, Mineral Processing Plant Design); water 1.000 t/m3.

Settling test (Coe and Clevenger): five points, one below the feed concentration is ignored, the largest area governs

Thickener Sizing. Inputs: feed_solids = 100, feed_solids_pct = 20, solids_sg = 2.7, underflow_solids_pct = 60, solids_to_underflow = 100, settling_test = 150:3.0; 250:1.2; 400:0.5; 600:0.25; 800:0.12.

QuantityReferenceProgramDifferenceResult
Feed solids 2,400 t/d 2,400 +0.0000 % Pass
Feed slurry flow 437.037 m3/h 437.04 +0.0007 % Pass
Underflow slurry flow 103.704 m3/h 103.7 -0.0036 % Pass
Overflow flow 333.333 m3/h 333.33 -0.0010 % Pass
Overflow solids concentration 0 % w/w 0 0 Pass
Design area 292.593 m2 292.6 +0.0025 % Pass
Diameter of each thickener 19.3013 m 19.3 -0.0068 % Pass
Unit area provided 0.121914 m2/(t/d) 0.1219 -0.0111 % Pass
Solids flux provided 0.341772 t/(m2.h) 0.3418 +0.0081 % Pass
Rise rate provided 1.13924 m/h 1.139 -0.0211 % Pass
Concentration governing the settling test 400 kg/m3 400 +0.0000 % Pass
Area from the settling test 292.593 m2 292.6 +0.0025 % Pass

Basis: rho = 1 / (C/SG + (1 - C)), Q = mass / rho for the feed, underflow and overflow; underflow solids = feed solids x recovery; overflow = feed - underflow (mass); A = unit area x t/d, or M / flux, or Q_overflow / rise rate (the largest, x (1 + margin)); D = sqrt(4 A / (pi N)); V = A x depth; retention = V / Q_feed. Source: Thickener sizing by the unit area and solids flux methods (Coe and Clevenger; Mular and Bhappu, Mineral Processing Plant Design); water 1.000 t/m3.

Process equipment: motor selection

The motor rating for an absorbed shaft power: the power at the motor shaft is the absorbed power over the transmission efficiency, a design margin is added and the motor is the first standard size at or above it (IEC kW, NEMA hp or the person's own list); the electrical input and full-load current follow from the motor efficiency, voltage and power factor. The reference searches the standard lists directly. The margin and the efficiencies are inputs from the specification and the motor data sheet.

37.4 kW absorbed, 96 % belt drive, 10 % margin: IEC list

Motor Selection. Inputs: absorbed_power = 37.4, transmission_efficiency = 96, design_margin = 10, standard_series = iec.

QuantityReferenceProgramDifferenceResult
Required motor shaft power 42.8542 kW 42.85 -0.0097 % Pass
Selected motor 45 kW 45 +0.0000 % Pass
Selected motor 60.346 hp 60.3 -0.0762 % Pass
Margin provided 15.508 % 15.5 -0.0517 % Pass
Motor loading at the duty point 86.5741 % 86.6 +0.0299 % Pass

Basis: shaft = P / eta; required = shaft x (1 + margin); the motor is the first size in the list that is >= required; loading = shaft / size; margin = size / shaft - 1; electrical input = shaft / motor efficiency; I = size x 1000 / (sqrt(3) V eta cos phi); 1 hp = 0.7457 kW. Source: IEC 60072-1 preferred output ratings; NEMA MG 1 integral horsepower ratings; three-phase current I = P / (sqrt(3) V eta cos phi).

A requirement that equals a standard size (50 kW at 100 %, 10 % margin is 55 kW): it must take 55, not 75

Motor Selection. Inputs: absorbed_power = 50, transmission_efficiency = 100, design_margin = 10, standard_series = iec.

QuantityReferenceProgramDifferenceResult
Required motor shaft power 55 kW 55 0.0000 % Pass
Selected motor 55 kW 55 +0.0000 % Pass
Selected motor 73.7562 hp 73.8 +0.0594 % Pass
Margin provided 10 % 10 0.0000 % Pass
Motor loading at the duty point 90.9091 % 90.9 -0.0100 % Pass

Basis: shaft = P / eta; required = shaft x (1 + margin); the motor is the first size in the list that is >= required; loading = shaft / size; margin = size / shaft - 1; electrical input = shaft / motor efficiency; I = size x 1000 / (sqrt(3) V eta cos phi); 1 hp = 0.7457 kW. Source: IEC 60072-1 preferred output ratings; NEMA MG 1 integral horsepower ratings; three-phase current I = P / (sqrt(3) V eta cos phi).

61 kW absorbed, 15 % margin: NEMA hp list

Motor Selection. Inputs: absorbed_power = 61, transmission_efficiency = 100, design_margin = 15, standard_series = nema.

QuantityReferenceProgramDifferenceResult
Required motor shaft power 70.15 kW 70.15 +0.0000 % Pass
Selected motor 74.57 kW 74.57 0.0000 % Pass
Selected motor 100 hp 100 +0.0000 % Pass
Margin provided 22.2459 % 22.2 -0.2063 % Pass
Motor loading at the duty point 81.8023 % 81.8 -0.0029 % Pass

Basis: shaft = P / eta; required = shaft x (1 + margin); the motor is the first size in the list that is >= required; loading = shaft / size; margin = size / shaft - 1; electrical input = shaft / motor efficiency; I = size x 1000 / (sqrt(3) V eta cos phi); 1 hp = 0.7457 kW. Source: IEC 60072-1 preferred output ratings; NEMA MG 1 integral horsepower ratings; three-phase current I = P / (sqrt(3) V eta cos phi).

Own list of sizes 7.5, 11, 15, 22 kW for 9.3 kW at 97 %, 12 % margin

Motor Selection. Inputs: absorbed_power = 9.3, transmission_efficiency = 97, design_margin = 12, custom_sizes = 7.5, 11, 15, 22.

QuantityReferenceProgramDifferenceResult
Required motor shaft power 10.7381 kW 10.74 +0.0173 % Pass
Selected motor 11 kW 11 +0.0000 % Pass
Selected motor 14.7512 hp 14.8 +0.3305 % Pass
Margin provided 14.7312 % 14.7 -0.2117 % Pass
Motor loading at the duty point 87.1603 % 87.2 +0.0456 % Pass

Basis: shaft = P / eta; required = shaft x (1 + margin); the motor is the first size in the list that is >= required; loading = shaft / size; margin = size / shaft - 1; electrical input = shaft / motor efficiency; I = size x 1000 / (sqrt(3) V eta cos phi); 1 hp = 0.7457 kW. Source: IEC 60072-1 preferred output ratings; NEMA MG 1 integral horsepower ratings; three-phase current I = P / (sqrt(3) V eta cos phi).

Electrical input and full-load current: 132 kW absorbed, 415 V, motor 95.5 %, power factor 0.88

Motor Selection. Inputs: absorbed_power = 132, transmission_efficiency = 98, design_margin = 10, standard_series = iec, voltage = 415, motor_efficiency = 95.5, power_factor = 0.88.

QuantityReferenceProgramDifferenceResult
Required motor shaft power 148.163 kW 148.16 -0.0022 % Pass
Selected motor 160 kW 160 +0.0000 % Pass
Selected motor 214.563 hp 214.6 +0.0170 % Pass
Margin provided 18.7879 % 18.8 +0.0645 % Pass
Motor loading at the duty point 84.1837 % 84.2 +0.0194 % Pass
Electrical input at the duty point 141.041 kW 141.04 -0.0005 % Pass
Full-load current 264.865 A 264.9 +0.0131 % Pass

Basis: shaft = P / eta; required = shaft x (1 + margin); the motor is the first size in the list that is >= required; loading = shaft / size; margin = size / shaft - 1; electrical input = shaft / motor efficiency; I = size x 1000 / (sqrt(3) V eta cos phi); 1 hp = 0.7457 kW. Source: IEC 60072-1 preferred output ratings; NEMA MG 1 integral horsepower ratings; three-phase current I = P / (sqrt(3) V eta cos phi).

Derated for altitude (0.92) with a locked-rotor ratio of 6.5: 75 kW absorbed, 415 V

Motor Selection. Inputs: absorbed_power = 75, transmission_efficiency = 100, design_margin = 10, derating_factor = 0.92, voltage = 415, motor_efficiency = 94, power_factor = 0.87, locked_rotor_ratio = 6.5.

QuantityReferenceProgramDifferenceResult
Required motor shaft power 89.6739 kW 89.67 -0.0044 % Pass
Selected motor 90 kW 90 +0.0000 % Pass
Selected motor 120.692 hp 120.7 +0.0067 % Pass
Margin provided 20 % 20 +0.0000 % Pass
Motor loading at the duty point 83.3333 % 83.3 -0.0400 % Pass
Electrical input at the duty point 79.7872 kW 79.79 +0.0035 % Pass
Full-load current 153.104 A 153.1 -0.0026 % Pass
Starting current 995.176 A 995 -0.0177 % Pass

Basis: shaft = P / eta; required = shaft x (1 + margin); the motor is the first size in the list that is >= required; loading = shaft / size; margin = size / shaft - 1; electrical input = shaft / motor efficiency; I = size x 1000 / (sqrt(3) V eta cos phi); 1 hp = 0.7457 kW. Source: IEC 60072-1 preferred output ratings; NEMA MG 1 integral horsepower ratings; three-phase current I = P / (sqrt(3) V eta cos phi).

Pipe pressure drop of a Bingham paste

A yield-stress paste in a straight pipe. The reference solves the Buckingham-Reiner laminar relation on the mean velocity (a different route from the program's Reynolds-number form) and joins it with the Darby and Melson turbulent factor by the rule of the owner's sheet Cal_304.

Tailings paste 80 m3/h in 200 mm, 1 km, tau0 100 Pa

Pipe Pressure Drop (Bingham Paste). Inputs: flow_rate = 80, pipe_diameter = 200, pipe_length = 1,000, fluid_density = 1,800, plastic_viscosity = 50, yield_stress = 100, elevation_change = 0.

QuantityReferenceProgramDifferenceResult
Friction pressure drop 2,180.59 kPa 2,180.59 +0.0001 % Pass
Friction gradient 2.18059 kPa/m 2.181 +0.0189 % Pass
Static pressure 0 kPa 0 0 Pass
Discharge pressure needed 2,180.59 kPa 2,180.59 +0.0001 % Pass
Start-up pressure 2,000 kPa 2,000 +0.0000 % Pass
Discharge pressure 2.18059 MPa 2.181 +0.0189 % Pass
Start-up pressure 2 MPa 2 +0.0000 % Pass
Velocity 0.707355 m/s 0.707 -0.0502 % Pass
Reynolds number 5,092.96 5,093 +0.0008 % Pass
Hedstrom number 2,880,000 2,880,000 +0.0000 % Pass
Fanning friction factor 0.242117 0.24212 +0.0011 % Pass
Wall shear stress 109.029 Pa 109.03 +0.0005 % Pass
Yield stress / wall shear stress 0.917183 0.917 -0.0200 % Pass

Basis: v = Q / A, Re = rho v D / mu_p, He = D^2 rho tau_0 / mu_p^2; laminar tau_w from v = (tau_w R / 4 mu_p)(1 - 4 phi/3 + phi^4/3), phi = tau_0 / tau_w, f_L = 2 tau_w / (rho v^2); turbulent f_T = 10^a / Re^0.193, a = -1.47 (1 + 0.146 exp(-2.9e-5 He)); f = (f_L^m + f_T^m)^(1/m), m = 1.7 + 40000/Re; dp = 2 f rho v^2 L / D; start-up 4 tau_0 L / D; static = rho g dz. Source: Buckingham-Reiner equation for the laminar flow of a Bingham plastic; Darby and Melson (1981) turbulent correlation; the joining rule of the owner's MEPL sheet Cal_304.

Stiff backfill paste 60 m3/h in 150 mm, 800 m, tau0 250 Pa, 30 m up

Pipe Pressure Drop (Bingham Paste). Inputs: flow_rate = 60, pipe_diameter = 150, pipe_length = 800, fluid_density = 2,000, plastic_viscosity = 80, yield_stress = 250, elevation_change = 30.

QuantityReferenceProgramDifferenceResult
Friction pressure drop 5,849.48 kPa 5,849.48 +0.0000 % Pass
Friction gradient 7.31185 kPa/m 7.312 +0.0021 % Pass
Static pressure 588.399 kPa 588.4 +0.0002 % Pass
Discharge pressure needed 6,437.88 kPa 6,437.88 +0.0001 % Pass
Start-up pressure 5,333.33 kPa 5,333.33 -0.0001 % Pass
Discharge pressure 6.43788 MPa 6.438 +0.0019 % Pass
Start-up pressure 5.33333 MPa 5.333 -0.0063 % Pass
Velocity 0.94314 m/s 0.943 -0.0149 % Pass
Reynolds number 3,536.78 3,536.8 +0.0007 % Pass
Hedstrom number 1,757,813 1,757,813 +0.0000 % Pass
Fanning friction factor 0.308252 0.30825 -0.0006 % Pass
Wall shear stress 274.194 Pa 274.19 -0.0016 % Pass
Yield stress / wall shear stress 0.911762 0.912 +0.0261 % Pass

Basis: v = Q / A, Re = rho v D / mu_p, He = D^2 rho tau_0 / mu_p^2; laminar tau_w from v = (tau_w R / 4 mu_p)(1 - 4 phi/3 + phi^4/3), phi = tau_0 / tau_w, f_L = 2 tau_w / (rho v^2); turbulent f_T = 10^a / Re^0.193, a = -1.47 (1 + 0.146 exp(-2.9e-5 He)); f = (f_L^m + f_T^m)^(1/m), m = 1.7 + 40000/Re; dp = 2 f rho v^2 L / D; start-up 4 tau_0 L / D; static = rho g dz. Source: Buckingham-Reiner equation for the laminar flow of a Bingham plastic; Darby and Melson (1981) turbulent correlation; the joining rule of the owner's MEPL sheet Cal_304.

Thin paste 400 m3/h in 200 mm, 500 m, tau0 15 Pa

Pipe Pressure Drop (Bingham Paste). Inputs: flow_rate = 400, pipe_diameter = 200, pipe_length = 500, fluid_density = 1,400, plastic_viscosity = 20, yield_stress = 15, elevation_change = 0.

QuantityReferenceProgramDifferenceResult
Friction pressure drop 401.912 kPa 401.91 -0.0006 % Pass
Friction gradient 0.803825 kPa/m 0.804 +0.0218 % Pass
Static pressure 0 kPa 0 0 Pass
Discharge pressure needed 401.912 kPa 401.91 -0.0006 % Pass
Start-up pressure 150 kPa 150 +0.0000 % Pass
Discharge pressure 0.401912 MPa 0.402 +0.0218 % Pass
Start-up pressure 0.15 MPa 0.15 +0.0000 % Pass
Velocity 3.53678 m/s 3.537 +0.0063 % Pass
Reynolds number 49,514.9 49,514.9 +0.0001 % Pass
Hedstrom number 2,100,000 2,100,000 0.0000 % Pass
Fanning friction factor 0.00459006 0.00459 -0.0013 % Pass
Wall shear stress 40.1912 Pa 40.19 -0.0031 % Pass
Yield stress / wall shear stress 0.373216 0.373 -0.0578 % Pass

Basis: v = Q / A, Re = rho v D / mu_p, He = D^2 rho tau_0 / mu_p^2; laminar tau_w from v = (tau_w R / 4 mu_p)(1 - 4 phi/3 + phi^4/3), phi = tau_0 / tau_w, f_L = 2 tau_w / (rho v^2); turbulent f_T = 10^a / Re^0.193, a = -1.47 (1 + 0.146 exp(-2.9e-5 He)); f = (f_L^m + f_T^m)^(1/m), m = 1.7 + 40000/Re; dp = 2 f rho v^2 L / D; start-up 4 tau_0 L / D; static = rho g dz. Source: Buckingham-Reiner equation for the laminar flow of a Bingham plastic; Darby and Melson (1981) turbulent correlation; the joining rule of the owner's MEPL sheet Cal_304.

Paste 150 m3/h in 300 mm, 2 km, tau0 60 Pa, 25 m down

Pipe Pressure Drop (Bingham Paste). Inputs: flow_rate = 150, pipe_diameter = 300, pipe_length = 2,000, fluid_density = 1,700, plastic_viscosity = 40, yield_stress = 60, elevation_change = -25.

QuantityReferenceProgramDifferenceResult
Friction pressure drop 1,723.1 kPa 1,723.1 -0.0002 % Pass
Friction gradient 0.861552 kPa/m 0.862 +0.0520 % Pass
Static pressure -416.783 kPa -416.78 +0.0006 % Pass
Discharge pressure needed 1,306.32 kPa 1,306.32 -0.0001 % Pass
Start-up pressure 1,600 kPa 1,600 +0.0000 % Pass
Discharge pressure 1.30632 MPa 1.306 -0.0246 % Pass
Start-up pressure 1.6 MPa 1.6 +0.0000 % Pass
Velocity 0.589463 m/s 0.589 -0.0785 % Pass
Reynolds number 7,515.65 7,515.7 +0.0007 % Pass
Hedstrom number 5,737,500 5,737,500 +0.0000 % Pass
Fanning friction factor 0.218782 0.21878 -0.0008 % Pass
Wall shear stress 64.6164 Pa 64.62 +0.0056 % Pass
Yield stress / wall shear stress 0.928557 0.929 +0.0477 % Pass

Basis: v = Q / A, Re = rho v D / mu_p, He = D^2 rho tau_0 / mu_p^2; laminar tau_w from v = (tau_w R / 4 mu_p)(1 - 4 phi/3 + phi^4/3), phi = tau_0 / tau_w, f_L = 2 tau_w / (rho v^2); turbulent f_T = 10^a / Re^0.193, a = -1.47 (1 + 0.146 exp(-2.9e-5 He)); f = (f_L^m + f_T^m)^(1/m), m = 1.7 + 40000/Re; dp = 2 f rho v^2 L / D; start-up 4 tau_0 L / D; static = rho g dz. Source: Buckingham-Reiner equation for the laminar flow of a Bingham plastic; Darby and Melson (1981) turbulent correlation; the joining rule of the owner's MEPL sheet Cal_304.

Plate backing ring flanges (AS 1210 loose flange method)

A plate ring held behind a plastic stub end. The reference is a separate implementation of the Taylor Forge loose flange method, checked in the script against the cached results of the workbook Cal_152 (four sizes); the thin-plate and hard-gasket cases test the other branches.

DN63 PE stub end, ANSI Class 150 plate ring, 1.06 MPa

Plate Backing Ring Flange (AS 1210). Inputs: pressure = 1.06, ring_stress = 108, bolt_stress_design = 172, bolt_stress_ambient = 172, gasket_m = 0.5, gasket_y = 0, stub_od = 95, stub_id = 75, ring_od = 152, ring_id = 74, pcd = 121, thickness = 20, bolt_count = 4, bolt_size = M16, nut_factor = 0.15.

QuantityReferenceProgramDifferenceResult
Gasket force diameter G 84.5 mm 84.5 +0.0000 % Pass
Bolt area required 42.723 mm2 42.72 -0.0071 % Pass
Operating moment 158.03 N.m 158.03 +0.0002 % Pass
Gasket seating moment 971.086 N.m 971.09 +0.0004 % Pass
Tangential stress, operating 15.2498 MPa 15.25 +0.0012 % Pass
Tangential stress, gasket seating 93.7095 MPa 93.71 +0.0005 % Pass
Minimum plate thickness 7.51537 mm 7.52 +0.0616 % Pass
Minimum bolt torque (each) 4.40902 N.m 4.41 +0.0223 % Pass
Maximum bolt torque (each) 36.7948 N.m 36.79 -0.0130 % Pass

Basis: N = (stub OD - stub ID)/2, b0 = N/2, b = b0 (b0 <= 6) or 2.52 sqrt(b0), G = (stub OD + B)/2; Wm1 = 0.785 G^2 P + 2 b pi G m P, Wm2 = pi b G y; Am = max(Wm1/Sb, Wm2/Sa); W = (Am + Ab) Sa / 2; H = 0.785 G^2 P, HD = 0.785 B^2 P, HT = H - HD, HG = Wm1 - H; hD = (C - B)/2, hT = hG = (C - G)/2; Mo = HD hD + HT hT + HG hG, Ma = W hG; K = A/B, Y = 1/(K-1) (0.66845 + 5.7169 K^2 log10 K/(K^2 - 1)); S = Y M / (t^2 B); t_min = sqrt(Y M / (S_allowable B)); torque = nut factor x bolt diameter x bolt force. Source: Owner's workbook Cal_152 (AS 1210 multiple flange backing ring stress calculation, ANSI Class 150 rings on PE stub ends), cached results; AS 1210 / Taylor Forge loose flange method.

DN200 PE stub end, ANSI Class 150 plate ring, 1.06 MPa

Plate Backing Ring Flange (AS 1210). Inputs: pressure = 1.06, ring_stress = 108, bolt_stress_design = 172, bolt_stress_ambient = 172, gasket_m = 0.5, gasket_y = 0, stub_od = 270, stub_id = 225, ring_od = 343, ring_id = 230, pcd = 299, thickness = 20, bolt_count = 8, bolt_size = M20, nut_factor = 0.15.

QuantityReferenceProgramDifferenceResult
Gasket force diameter G 250 mm 250 +0.0000 % Pass
Bolt area required 343.273 mm2 343.27 -0.0010 % Pass
Operating moment 1,886.73 N.m 1,886.73 -0.0002 % Pass
Gasket seating moment 4,515.88 N.m 4,515.88 +0.0001 % Pass
Tangential stress, operating 103.161 MPa 103.16 -0.0005 % Pass
Tangential stress, gasket seating 246.914 MPa 246.91 -0.0014 % Pass
Minimum plate thickness 19.5468 mm 19.55 +0.0165 % Pass
Minimum bolt torque (each) 22.1411 N.m 22.14 -0.0051 % Pass
Maximum bolt torque (each) 30.2333 N.m 30.23 -0.0111 % Pass

Basis: N = (stub OD - stub ID)/2, b0 = N/2, b = b0 (b0 <= 6) or 2.52 sqrt(b0), G = (stub OD + B)/2; Wm1 = 0.785 G^2 P + 2 b pi G m P, Wm2 = pi b G y; Am = max(Wm1/Sb, Wm2/Sa); W = (Am + Ab) Sa / 2; H = 0.785 G^2 P, HD = 0.785 B^2 P, HT = H - HD, HG = Wm1 - H; hD = (C - B)/2, hT = hG = (C - G)/2; Mo = HD hD + HT hT + HG hG, Ma = W hG; K = A/B, Y = 1/(K-1) (0.66845 + 5.7169 K^2 log10 K/(K^2 - 1)); S = Y M / (t^2 B); t_min = sqrt(Y M / (S_allowable B)); torque = nut factor x bolt diameter x bolt force. Source: Owner's workbook Cal_152 (AS 1210 multiple flange backing ring stress calculation, ANSI Class 150 rings on PE stub ends), cached results; AS 1210 / Taylor Forge loose flange method.

DN315 PE stub end, ANSI Class 150 plate ring, 1.06 MPa

Plate Backing Ring Flange (AS 1210). Inputs: pressure = 1.06, ring_stress = 108, bolt_stress_design = 172, bolt_stress_ambient = 172, gasket_m = 0.5, gasket_y = 0, stub_od = 380, stub_id = 335, ring_od = 483, ring_id = 345, pcd = 432, thickness = 35, bolt_count = 12, bolt_size = M24, nut_factor = 0.15.

QuantityReferenceProgramDifferenceResult
Gasket force diameter G 362.5 mm 362.5 +0.0000 % Pass
Bolt area required 695.037 mm2 695.04 +0.0004 % Pass
Operating moment 5,020.84 N.m 5,020.84 -0.0001 % Pass
Gasket seating moment 13,696.4 N.m 13,696.4 +0.0000 % Pass
Tangential stress, operating 70.5103 MPa 70.51 -0.0005 % Pass
Tangential stress, gasket seating 192.346 MPa 192.35 +0.0022 % Pass
Minimum plate thickness 28.2802 mm 28.28 -0.0007 % Pass
Minimum bolt torque (each) 35.8639 N.m 35.86 -0.0110 % Pass
Maximum bolt torque (each) 66.3918 N.m 66.39 -0.0027 % Pass

Basis: N = (stub OD - stub ID)/2, b0 = N/2, b = b0 (b0 <= 6) or 2.52 sqrt(b0), G = (stub OD + B)/2; Wm1 = 0.785 G^2 P + 2 b pi G m P, Wm2 = pi b G y; Am = max(Wm1/Sb, Wm2/Sa); W = (Am + Ab) Sa / 2; H = 0.785 G^2 P, HD = 0.785 B^2 P, HT = H - HD, HG = Wm1 - H; hD = (C - B)/2, hT = hG = (C - G)/2; Mo = HD hD + HT hT + HG hG, Ma = W hG; K = A/B, Y = 1/(K-1) (0.66845 + 5.7169 K^2 log10 K/(K^2 - 1)); S = Y M / (t^2 B); t_min = sqrt(Y M / (S_allowable B)); torque = nut factor x bolt diameter x bolt force. Source: Owner's workbook Cal_152 (AS 1210 multiple flange backing ring stress calculation, ANSI Class 150 rings on PE stub ends), cached results; AS 1210 / Taylor Forge loose flange method.

DN630 PE stub end, ANSI Class 150 plate ring, 1.06 MPa

Plate Backing Ring Flange (AS 1210). Inputs: pressure = 1.06, ring_stress = 108, bolt_stress_design = 172, bolt_stress_ambient = 172, gasket_m = 0.5, gasket_y = 0, stub_od = 710, stub_id = 650, ring_od = 813, ring_id = 660, pcd = 749, thickness = 50, bolt_count = 16, bolt_size = M30, nut_factor = 0.15.

QuantityReferenceProgramDifferenceResult
Gasket force diameter G 685 mm 685 +0.0000 % Pass
Bolt area required 2,399.45 mm2 2,399.45 0.0000 % Pass
Operating moment 17,737.4 N.m 17,737.4 0.0000 % Pass
Gasket seating moment 29,455.9 N.m 29,455.9 +0.0000 % Pass
Tangential stress, operating 101.398 MPa 101.4 +0.0017 % Pass
Tangential stress, gasket seating 168.389 MPa 168.39 +0.0006 % Pass
Minimum plate thickness 48.4477 mm 48.45 +0.0047 % Pass
Minimum bolt torque (each) 116.073 N.m 116.07 -0.0030 % Pass
Maximum bolt torque (each) 166.045 N.m 166.04 -0.0028 % Pass

Basis: N = (stub OD - stub ID)/2, b0 = N/2, b = b0 (b0 <= 6) or 2.52 sqrt(b0), G = (stub OD + B)/2; Wm1 = 0.785 G^2 P + 2 b pi G m P, Wm2 = pi b G y; Am = max(Wm1/Sb, Wm2/Sa); W = (Am + Ab) Sa / 2; H = 0.785 G^2 P, HD = 0.785 B^2 P, HT = H - HD, HG = Wm1 - H; hD = (C - B)/2, hT = hG = (C - G)/2; Mo = HD hD + HT hT + HG hG, Ma = W hG; K = A/B, Y = 1/(K-1) (0.66845 + 5.7169 K^2 log10 K/(K^2 - 1)); S = Y M / (t^2 B); t_min = sqrt(Y M / (S_allowable B)); torque = nut factor x bolt diameter x bolt force. Source: Owner's workbook Cal_152 (AS 1210 multiple flange backing ring stress calculation, ANSI Class 150 rings on PE stub ends), cached results; AS 1210 / Taylor Forge loose flange method.

DN200 PE stub end, PN16 plate ring 24 mm, 1.0 MPa

Plate Backing Ring Flange (AS 1210). Inputs: pressure = 1, ring_stress = 108, bolt_stress_design = 172, bolt_stress_ambient = 172, gasket_m = 0.5, gasket_y = 0, stub_od = 270, stub_id = 225, ring_od = 340, ring_id = 230, pcd = 295, thickness = 24, bolt_count = 12, bolt_size = M20, nut_factor = 0.15.

QuantityReferenceProgramDifferenceResult
Gasket force diameter G 250 mm 250 +0.0000 % Pass
Bolt area required 323.843 mm2 323.84 -0.0008 % Pass
Operating moment 1,668.54 N.m 1,668.54 +0.0002 % Pass
Gasket seating moment 5,851.14 N.m 5,851.14 +0.0001 % Pass
Tangential stress, operating 64.7208 MPa 64.72 -0.0012 % Pass
Tangential stress, gasket seating 226.959 MPa 226.96 +0.0002 % Pass
Minimum plate thickness 18.579 mm 18.58 +0.0056 % Pass
Minimum bolt torque (each) 13.9252 N.m 13.93 +0.0342 % Pass
Maximum bolt torque (each) 30.9366 N.m 30.94 +0.0109 % Pass

Basis: N = (stub OD - stub ID)/2, b0 = N/2, b = b0 (b0 <= 6) or 2.52 sqrt(b0), G = (stub OD + B)/2; Wm1 = 0.785 G^2 P + 2 b pi G m P, Wm2 = pi b G y; Am = max(Wm1/Sb, Wm2/Sa); W = (Am + Ab) Sa / 2; H = 0.785 G^2 P, HD = 0.785 B^2 P, HT = H - HD, HG = Wm1 - H; hD = (C - B)/2, hT = hG = (C - G)/2; Mo = HD hD + HT hT + HG hG, Ma = W hG; K = A/B, Y = 1/(K-1) (0.66845 + 5.7169 K^2 log10 K/(K^2 - 1)); S = Y M / (t^2 B); t_min = sqrt(Y M / (S_allowable B)); torque = nut factor x bolt diameter x bolt force. Source: Same method; PN16 outside diameter 340, bolt circle 295, 12 bolts M20, plate 24 mm (a supplier's plate flange table).

DN200 plate 12 mm with a hard gasket (m = 3, y = 25 MPa), 1.06 MPa

Plate Backing Ring Flange (AS 1210). Inputs: pressure = 1.06, ring_stress = 108, bolt_stress_design = 172, bolt_stress_ambient = 172, gasket_m = 3, gasket_y = 25, stub_od = 270, stub_id = 225, ring_od = 343, ring_id = 230, pcd = 299, thickness = 12, bolt_count = 8, bolt_size = M20, nut_factor = 0.15.

QuantityReferenceProgramDifferenceResult
Gasket force diameter G 250 mm 250 +0.0000 % Pass
Bolt area required 964.891 mm2 964.89 -0.0001 % Pass
Operating moment 2,748.74 N.m 2,748.74 +0.0001 % Pass
Gasket seating moment 5,825.63 N.m 5,825.63 +0.0001 % Pass
Tangential stress, operating 417.478 MPa 417.48 +0.0005 % Pass
Tangential stress, gasket seating 884.795 MPa 884.8 +0.0005 % Pass
Minimum plate thickness 34.3472 mm 34.35 +0.0083 % Pass
Minimum bolt torque (each) 62.2355 N.m 62.24 +0.0073 % Pass
Maximum bolt torque (each) 10.884 N.m 10.88 -0.0368 % Pass

Basis: N = (stub OD - stub ID)/2, b0 = N/2, b = b0 (b0 <= 6) or 2.52 sqrt(b0), G = (stub OD + B)/2; Wm1 = 0.785 G^2 P + 2 b pi G m P, Wm2 = pi b G y; Am = max(Wm1/Sb, Wm2/Sa); W = (Am + Ab) Sa / 2; H = 0.785 G^2 P, HD = 0.785 B^2 P, HT = H - HD, HG = Wm1 - H; hD = (C - B)/2, hT = hG = (C - G)/2; Mo = HD hD + HT hT + HG hG, Ma = W hG; K = A/B, Y = 1/(K-1) (0.66845 + 5.7169 K^2 log10 K/(K^2 - 1)); S = Y M / (t^2 B); t_min = sqrt(Y M / (S_allowable B)); torque = nut factor x bolt diameter x bolt force. Source: Same method with the seating condition (y > 0) governing the minimum plate thickness.

Fluid properties (library fluids)

Each case reads the block at a temperature that is not on the table's grid and compares it with CoolProp evaluated directly at that point (CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)). Tolerance 0.2 to 0.4 % for liquids (the interpolation error is far below it) and 0.7 % for gases (near the dew point and at several MPa are the least accurate part). Two water cases are the NIST WebBook saturation values.

water, liquid, 12.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 12.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 999.418 kg/m³ 999.38 -0.0039 % Pass
Dynamic Viscosity 1.22389 mPa·s 1.22565 +0.1441 % Pass
Specific Heat, cp 4.19211 kJ/(kg·K) 4.19244 +0.0080 % Pass
Thermal Conductivity 0.583434 W/(m·K) 0.583325 -0.0187 % Pass
Vapour Pressure (absolute) 1.43085 kPa 1.43058 -0.0186 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, liquid, 37.7 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 37.7, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 993.034 kg/m³ 993.01 -0.0024 % Pass
Dynamic Viscosity 0.681967 mPa·s 0.682464 +0.0728 % Pass
Specific Heat, cp 4.1795 kJ/(kg·K) 4.17958 +0.0019 % Pass
Thermal Conductivity 0.625376 W/(m·K) 0.625314 -0.0099 % Pass
Vapour Pressure (absolute) 6.52594 kPa 6.52496 -0.0150 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, liquid, 63.1 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 63.1, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 981.539 kg/m³ 981.521 -0.0018 % Pass
Dynamic Viscosity 0.444995 mPa·s 0.445187 +0.0431 % Pass
Specific Heat, cp 4.18655 kJ/(kg·K) 4.18659 +0.0009 % Pass
Thermal Conductivity 0.653842 W/(m·K) 0.653796 -0.0071 % Pass
Vapour Pressure (absolute) 22.9888 kPa 22.9861 -0.0116 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, liquid, 87.9 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 87.9, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 966.694 kg/m³ 966.68 -0.0015 % Pass
Dynamic Viscosity 0.321869 mPa·s 0.32197 +0.0315 % Pass
Specific Heat, cp 4.20335 kJ/(kg·K) 4.20342 +0.0016 % Pass
Thermal Conductivity 0.671668 W/(m·K) 0.671625 -0.0064 % Pass
Vapour Pressure (absolute) 64.7672 kPa 64.7611 -0.0095 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, liquid, 121.3 °C, 500 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 121.3, pressure = 500.

QuantityReferenceProgramDifferenceResult
Density 942.055 kg/m³ 942.045 -0.0011 % Pass
Dynamic Viscosity 0.229371 mPa·s 0.229409 +0.0165 % Pass
Specific Heat, cp 4.24568 kJ/(kg·K) 4.24575 +0.0015 % Pass
Thermal Conductivity 0.6824 W/(m·K) 0.682372 -0.0041 % Pass
Vapour Pressure (absolute) 206.993 kPa 206.982 -0.0055 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, liquid, 187.7 °C, 1500 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 187.7, pressure = 1,500.

QuantityReferenceProgramDifferenceResult
Density 878.631 kg/m³ 878.616 -0.0017 % Pass
Dynamic Viscosity 0.143877 mPa·s 0.143891 +0.0101 % Pass
Specific Heat, cp 4.43714 kJ/(kg·K) 4.43732 +0.0041 % Pass
Thermal Conductivity 0.667367 W/(m·K) 0.667339 -0.0042 % Pass
Vapour Pressure (absolute) 1,193.2 kPa 1,193.16 -0.0030 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, liquid, 250.3 °C, 5000 kPa abs

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 250.3, pressure = 5,000.

QuantityReferenceProgramDifferenceResult
Density 798.448 kg/m³ 798.442 -0.0007 % Pass
Dynamic Viscosity 0.106145 mPa·s 0.106146 +0.0006 % Pass
Specific Heat, cp 4.87333 kJ/(kg·K) 4.87345 +0.0025 % Pass
Thermal Conductivity 0.616566 W/(m·K) 0.61656 -0.0010 % Pass
Vapour Pressure (absolute) 3,996.36 kPa 3,996.35 -0.0003 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, gas, 168.3 °C, 450 kPa abs

Fluid Properties. Inputs: fluid = water, phase = gas, temperature = 168.3, pressure = 450.

QuantityReferenceProgramDifferenceResult
Density 2.28377 kg/m³ 2.2857 +0.0846 % Pass
Dynamic Viscosity 0.0147472 mPa·s 0.014743 -0.0288 % Pass
Specific Heat, cp 2.21548 kJ/(kg·K) 2.22798 +0.5640 % Pass
Thermal Conductivity 0.0317372 W/(m·K) 0.031775 +0.1191 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

water, gas, 212.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = water, phase = gas, temperature = 212.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 0.454388 kg/m³ 0.4544 +0.0027 % Pass
Dynamic Viscosity 0.0167042 mPa·s 0.016704 -0.0012 % Pass
Specific Heat, cp 1.97792 kJ/(kg·K) 1.97798 +0.0030 % Pass
Thermal Conductivity 0.0346176 W/(m·K) 0.034619 +0.0042 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

ammonia, liquid, 12.3 °C, 1000 kPa abs

Fluid Properties. Inputs: fluid = ammonia, phase = liquid, temperature = 12.3, pressure = 1,000.

QuantityReferenceProgramDifferenceResult
Density 621.524 kg/m³ 621.507 -0.0028 % Pass
Dynamic Viscosity 0.144559 mPa·s 0.144582 +0.0158 % Pass
Specific Heat, cp 4.68325 kJ/(kg·K) 4.68366 +0.0088 % Pass
Thermal Conductivity 0.497508 W/(m·K) 0.497476 -0.0065 % Pass
Vapour Pressure (absolute) 665.115 kPa 665.064 -0.0077 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

propane, liquid, 7.7 °C, 1000 kPa abs

Fluid Properties. Inputs: fluid = propane, phase = liquid, temperature = 7.7, pressure = 1,000.

QuantityReferenceProgramDifferenceResult
Density 517.982 kg/m³ 517.958 -0.0047 % Pass
Dynamic Viscosity 0.116049 mPa·s 0.11605 +0.0006 % Pass
Specific Heat, cp 2.55383 kJ/(kg·K) 2.5542 +0.0144 % Pass
Thermal Conductivity 0.102252 W/(m·K) 0.102258 +0.0062 % Pass
Vapour Pressure (absolute) 596.144 kPa 596.126 -0.0031 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

r134a, liquid, 27.7 °C, 1000 kPa abs

Fluid Properties. Inputs: fluid = r134a, phase = liquid, temperature = 27.7, pressure = 1,000.

QuantityReferenceProgramDifferenceResult
Density 1,196.4 kg/m³ 1,196.32 -0.0071 % Pass
Dynamic Viscosity 0.188453 mPa·s 0.188446 -0.0037 % Pass
Specific Heat, cp 1.43613 kJ/(kg·K) 1.43641 +0.0195 % Pass
Thermal Conductivity 0.0799791 W/(m·K) 0.07998 +0.0011 % Pass
Vapour Pressure (absolute) 720.545 kPa 720.509 -0.0051 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

ethanol, liquid, 17.2 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = ethanol, phase = liquid, temperature = 17.2, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 791.729 kg/m³ 791.727 -0.0003 % Pass
Dynamic Viscosity 1.26192 mPa·s 1.26236 +0.0350 % Pass
Specific Heat, cp 2.37519 kJ/(kg·K) 2.37538 +0.0079 % Pass
Thermal Conductivity 0.165025 W/(m·K) 0.16503 +0.0030 % Pass
Vapour Pressure (absolute) 4.95833 kPa 4.95746 -0.0175 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

ethanol, liquid, 64.1 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = ethanol, phase = liquid, temperature = 64.1, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 750.175 kg/m³ 750.17 -0.0007 % Pass
Dynamic Viscosity 0.547327 mPa·s 0.547405 +0.0142 % Pass
Specific Heat, cp 2.78412 kJ/(kg·K) 2.78421 +0.0031 % Pass
Thermal Conductivity 0.156597 W/(m·K) 0.156598 +0.0004 % Pass
Vapour Pressure (absolute) 55.9938 kPa 55.9896 -0.0076 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

methanol, liquid, 33.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = methanol, phase = liquid, temperature = 33.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 778.438 kg/m³ 778.436 -0.0003 % Pass
Dynamic Viscosity 0.483239 mPa·s 0.483353 +0.0237 % Pass
Specific Heat, cp 2.58789 kJ/(kg·K) 2.58807 +0.0070 % Pass
Thermal Conductivity 0.198591 W/(m·K) 0.198591 -0.0001 % Pass
Vapour Pressure (absolute) 25.8005 kPa 25.7978 -0.0104 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

n-hexane, liquid, 33.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = n-hexane, phase = liquid, temperature = 33.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 647.165 kg/m³ 647.16 -0.0007 % Pass
Dynamic Viscosity 0.274725 mPa·s 0.274754 +0.0107 % Pass
Specific Heat, cp 2.30796 kJ/(kg·K) 2.30801 +0.0023 % Pass
Thermal Conductivity 0.117459 W/(m·K) 0.117462 +0.0025 % Pass
Vapour Pressure (absolute) 28.5777 kPa 28.5736 -0.0142 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

toluene, liquid, 83.9 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = toluene, phase = liquid, temperature = 83.9, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 805.964 kg/m³ 805.961 -0.0004 % Pass
Dynamic Viscosity 0.306641 mPa·s 0.30667 +0.0093 % Pass
Specific Heat, cp 1.90374 kJ/(kg·K) 1.90376 +0.0008 % Pass
Thermal Conductivity 0.114175 W/(m·K) 0.114176 +0.0010 % Pass
Vapour Pressure (absolute) 44.394 kPa 44.3907 -0.0075 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

n-dodecane, liquid, 47.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = n-dodecane, phase = liquid, temperature = 47.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 729.166 kg/m³ 729.165 0.0000 % Pass
Dynamic Viscosity 0.950665 mPa·s 0.951027 +0.0381 % Pass
Specific Heat, cp 2.28811 kJ/(kg·K) 2.28814 +0.0015 % Pass
Thermal Conductivity 0.130033 W/(m·K) 0.130034 +0.0011 % Pass
Vapour Pressure (absolute) 0.0977645 kPa 0.09773 -0.0353 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

air, gas, 23.4 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = air, phase = gas, temperature = 23.4, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1.19073 kg/m³ 1.1907 -0.0022 % Pass
Dynamic Viscosity 0.0183707 mPa·s 0.01837 -0.0038 % Pass
Specific Heat, cp 1.00625 kJ/(kg·K) 1.00626 +0.0006 % Pass
Thermal Conductivity 0.0261278 W/(m·K) 0.026127 -0.0029 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

air, gas, 57.3 °C, 733 kPa abs

Fluid Properties. Inputs: fluid = air, phase = gas, temperature = 57.3, pressure = 733.

QuantityReferenceProgramDifferenceResult
Density 7.7318 kg/m³ 7.7318 +0.0001 % Pass
Dynamic Viscosity 0.0200613 mPa·s 0.020061 -0.0016 % Pass
Specific Heat, cp 1.01577 kJ/(kg·K) 1.01583 +0.0057 % Pass
Thermal Conductivity 0.0287951 W/(m·K) 0.028795 -0.0002 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

air, gas, 233.3 °C, 3500 kPa abs

Fluid Properties. Inputs: fluid = air, phase = gas, temperature = 233.3, pressure = 3,500.

QuantityReferenceProgramDifferenceResult
Density 23.7806 kg/m³ 23.7772 -0.0142 % Pass
Dynamic Viscosity 0.0276831 mPa·s 0.027687 +0.0139 % Pass
Specific Heat, cp 1.04638 kJ/(kg·K) 1.04654 +0.0149 % Pass
Thermal Conductivity 0.0410177 W/(m·K) 0.041026 +0.0203 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

nitrogen, gas, -73.3 °C, 2500 kPa abs

Fluid Properties. Inputs: fluid = nitrogen, phase = gas, temperature = -73.3, pressure = 2,500.

QuantityReferenceProgramDifferenceResult
Density 44.4601 kg/m³ 44.5139 +0.1211 % Pass
Dynamic Viscosity 0.0135386 mPa·s 0.013561 +0.1657 % Pass
Specific Heat, cp 1.16265 kJ/(kg·K) 1.16659 +0.3385 % Pass
Thermal Conductivity 0.0201367 W/(m·K) 0.020195 +0.2893 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

methane, gas, 15.6 °C, 7500 kPa abs

Fluid Properties. Inputs: fluid = methane, phase = gas, temperature = 15.6, pressure = 7,500.

QuantityReferenceProgramDifferenceResult
Density 57.9701 kg/m³ 57.9969 +0.0462 % Pass
Dynamic Viscosity 0.0125489 mPa·s 0.012551 +0.0164 % Pass
Specific Heat, cp 2.84643 kJ/(kg·K) 2.84952 +0.1086 % Pass
Thermal Conductivity 0.0401731 W/(m·K) 0.040192 +0.0471 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

hydrogen, gas, 33.3 °C, 8000 kPa abs

Fluid Properties. Inputs: fluid = hydrogen, phase = gas, temperature = 33.3, pressure = 8,000.

QuantityReferenceProgramDifferenceResult
Density 6.04556 kg/m³ 6.0434 -0.0357 % Pass
Dynamic Viscosity 0.00915208 mPa·s 0.009153 +0.0101 % Pass
Specific Heat, cp 14.519 kJ/(kg·K) 14.5195 +0.0032 % Pass
Thermal Conductivity 0.197234 W/(m·K) 0.197253 +0.0097 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

co2, gas, 87.3 °C, 3000 kPa abs

Fluid Properties. Inputs: fluid = co2, phase = gas, temperature = 87.3, pressure = 3,000.

QuantityReferenceProgramDifferenceResult
Density 47.9507 kg/m³ 47.9566 +0.0123 % Pass
Dynamic Viscosity 0.0183557 mPa·s 0.018355 -0.0040 % Pass
Specific Heat, cp 1.03404 kJ/(kg·K) 1.03429 +0.0245 % Pass
Thermal Conductivity 0.023229 W/(m·K) 0.02323 +0.0042 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

propane, gas, 55.5 °C, 600 kPa abs

Fluid Properties. Inputs: fluid = propane, phase = gas, temperature = 55.5, pressure = 600.

QuantityReferenceProgramDifferenceResult
Density 10.4558 kg/m³ 10.4789 +0.2209 % Pass
Dynamic Viscosity 0.0090091 mPa·s 0.009014 +0.0543 % Pass
Specific Heat, cp 1.90774 kJ/(kg·K) 1.91235 +0.2417 % Pass
Thermal Conductivity 0.0221153 W/(m·K) 0.022136 +0.0935 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

oxygen, gas, 7.7 °C, 1500 kPa abs

Fluid Properties. Inputs: fluid = oxygen, phase = gas, temperature = 7.7, pressure = 1,500.

QuantityReferenceProgramDifferenceResult
Density 20.8142 kg/m³ 20.8148 +0.0028 % Pass
Dynamic Viscosity 0.0198951 mPa·s 0.019894 -0.0053 % Pass
Specific Heat, cp 0.943647 kJ/(kg·K) 0.94369 +0.0046 % Pass
Thermal Conductivity 0.0256526 W/(m·K) 0.025652 -0.0025 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

meg-30, liquid, 7.7 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = meg-30, phase = liquid, temperature = 7.7, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1,042.59 kg/m³ 1,042.57 -0.0020 % Pass
Dynamic Viscosity 3.23081 mPa·s 3.23547 +0.1442 % Pass
Specific Heat, cp 3.68157 kJ/(kg·K) 3.68155 -0.0006 % Pass
Thermal Conductivity 0.45332 W/(m·K) 0.453314 -0.0013 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

meg-30, liquid, 53.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = meg-30, phase = liquid, temperature = 53.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1,021.48 kg/m³ 1,021.47 -0.0013 % Pass
Dynamic Viscosity 0.976882 mPa·s 0.977594 +0.0729 % Pass
Specific Heat, cp 3.8113 kJ/(kg·K) 3.81128 -0.0005 % Pass
Thermal Conductivity 0.494553 W/(m·K) 0.494545 -0.0015 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

mpg-40, liquid, 22.2 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = mpg-40, phase = liquid, temperature = 22.2, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1,031.02 kg/m³ 1,031.01 -0.0015 % Pass
Dynamic Viscosity 4.00173 mPa·s 4.01009 +0.2089 % Pass
Specific Heat, cp 3.71383 kJ/(kg·K) 3.71382 -0.0002 % Pass
Thermal Conductivity 0.401664 W/(m·K) 0.401667 +0.0009 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

nacl-15, liquid, 33.3 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = nacl-15, phase = liquid, temperature = 33.3, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1,102.51 kg/m³ 1,102.5 -0.0010 % Pass
Dynamic Viscosity 1.01175 mPa·s 1.01293 +0.1170 % Pass
Specific Heat, cp 3.56609 kJ/(kg·K) 3.56597 -0.0034 % Pass
Thermal Conductivity 0.60469 W/(m·K) 0.60469 0.0000 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

seawater-3.5, liquid, 22.2 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = seawater-3.5, phase = liquid, temperature = 22.2, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1,024.36 kg/m³ 1,024.34 -0.0022 % Pass
Dynamic Viscosity 1.02922 mPa·s 1.03017 +0.0931 % Pass
Specific Heat, cp 4.00028 kJ/(kg·K) 4.00027 -0.0001 % Pass
Thermal Conductivity 0.604798 W/(m·K) 0.604753 -0.0074 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

seawater-3.5, liquid, 61.7 °C, 101.325 kPa abs

Fluid Properties. Inputs: fluid = seawater-3.5, phase = liquid, temperature = 61.7, pressure = 101.325.

QuantityReferenceProgramDifferenceResult
Density 1,008.1 kg/m³ 1,008.09 -0.0015 % Pass
Dynamic Viscosity 0.49314 mPa·s 0.49337 +0.0467 % Pass
Specific Heat, cp 4.01585 kJ/(kg·K) 4.01588 +0.0006 % Pass
Thermal Conductivity 0.650091 W/(m·K) 0.650055 -0.0056 % Pass

Basis: CoolProp PropsSI at this state (saturated liquid for a liquid, T and P for a gas). Source: CoolProp 8.1.0 PropsSI, evaluated directly at temperatures that are not on the tables' grid (tools/fluid-data/reference_points.py)

Water, saturated liquid at 20 °C: NIST WebBook

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 20, pressure = 500.

QuantityReferenceProgramDifferenceResult
Density 998.16 kg/m³ 998.162 +0.0002 % Pass
Dynamic Viscosity 1.0016 mPa·s 1.00163 +0.0030 % Pass
Specific Heat, cp 4.1844 kJ/(kg·K) 4.18436 -0.0010 % Pass
Thermal Conductivity 0.59795 W/(m·K) 0.597954 +0.0007 % Pass
Vapour Pressure (absolute) 2.3393 kPa 2.33932 +0.0009 % Pass

Basis: Published saturation table values (5 significant digits). Source: NIST Chemistry WebBook, Thermophysical Properties of Fluid Systems, water, saturation properties (webbook.nist.gov/cgi/fluid.cgi?ID=C7732185&Type=SatP).

Water, saturated liquid at 80 °C: NIST WebBook

Fluid Properties. Inputs: fluid = water, phase = liquid, temperature = 80, pressure = 500.

QuantityReferenceProgramDifferenceResult
Density 971.77 kg/m³ 971.766 -0.0004 % Pass
Dynamic Viscosity 0.35404 mPa·s 0.354036 -0.0011 % Pass
Specific Heat, cp 4.1969 kJ/(kg·K) 4.19687 -0.0007 % Pass
Thermal Conductivity 0.66697 W/(m·K) 0.666965 -0.0007 % Pass
Vapour Pressure (absolute) 47.414 kPa 47.4145 +0.0011 % Pass

Basis: Published saturation table values (5 significant digits). Source: NIST Chemistry WebBook, Thermophysical Properties of Fluid Systems, water, saturation properties (webbook.nist.gov/cgi/fluid.cgi?ID=C7732185&Type=SatP).

Pressure relief valve sizing (API 520 Part I)

Required effective area for gas (critical and subcritical), steam and liquid. The gas and liquid references are the isentropic-nozzle and Bernoulli equations in SI base units, NOT the API constants (0.03948, 17.9, 11.78), so each case also tests that the constants agree with the theory they come from (to 0.15 %). The steam cases only evaluate the Napier-form equation by hand: they test the code, not the constant 190.5 (which is marked unconfirmed in the block).

Gas, critical flow: propane

Relief Valve Sizing (API 520). Inputs: service = gas, mass_flow = 12,000, set_pressure = 1,500, overpressure = 10, back_pressure = 0, temperature = 60, molar_mass = 44.1, k = 1.13, z = 0.95, kd = 0.975, kb = 1, rupture_disk = no.

QuantityReferenceProgramDifferenceResult
Relieving Pressure P1 (absolute) 1,751.33 kPa (a) 1,751.33 0.0000 % Pass
Required Effective Area 751.457 mm² 751.471 +0.0019 % Pass
Effective Area of that Orifice 830 mm² 830 +0.0000 % Pass

Basis: Isentropic choked-nozzle mass flux in SI base units; A = W/(G Kb Kc). Source: Compressible flow through a nozzle (Shapiro, Dynamics and Thermodynamics of Compressible Fluid Flow); API 520 Part I gives the same equation with the constant 0.03948.

Gas, critical flow: air_hot

Relief Valve Sizing (API 520). Inputs: service = gas, mass_flow = 5,000, set_pressure = 700, overpressure = 10, back_pressure = 0, temperature = 180, molar_mass = 28.96, k = 1.4, z = 1, kd = 0.975, kb = 1, rupture_disk = no.

QuantityReferenceProgramDifferenceResult
Relieving Pressure P1 (absolute) 871.325 kPa (a) 871.325 0.0000 % Pass
Required Effective Area 861.194 mm² 861.211 +0.0019 % Pass
Effective Area of that Orifice 1,186 mm² 1,186 +0.0000 % Pass

Basis: Isentropic choked-nozzle mass flux in SI base units; A = W/(G Kb Kc). Source: Compressible flow through a nozzle (Shapiro, Dynamics and Thermodynamics of Compressible Fluid Flow); API 520 Part I gives the same equation with the constant 0.03948.

Gas, critical flow: hydrogen_disk

Relief Valve Sizing (API 520). Inputs: service = gas, mass_flow = 800, set_pressure = 3,000, overpressure = 21, back_pressure = 100, temperature = 40, molar_mass = 2.016, k = 1.41, z = 1, kd = 0.975, kb = 1, rupture_disk = yes.

QuantityReferenceProgramDifferenceResult
Relieving Pressure P1 (absolute) 3,731.33 kPa (a) 3,731.33 +0.0000 % Pass
Required Effective Area 112.367 mm² 112.369 +0.0018 % Pass
Effective Area of that Orifice 126 mm² 126 +0.0000 % Pass

Basis: Isentropic choked-nozzle mass flux in SI base units; A = W/(G Kb Kc). Source: Compressible flow through a nozzle (Shapiro, Dynamics and Thermodynamics of Compressible Fluid Flow); API 520 Part I gives the same equation with the constant 0.03948.

Gas, critical flow: methane_kb

Relief Valve Sizing (API 520). Inputs: service = gas, mass_flow = 30,000, set_pressure = 2,500, overpressure = 16, back_pressure = 150, temperature = 25, molar_mass = 16.04, k = 1.31, z = 0.9, kd = 0.9, kb = 0.95, rupture_disk = no.

QuantityReferenceProgramDifferenceResult
Relieving Pressure P1 (absolute) 3,001.33 kPa (a) 3,001.33 +0.0000 % Pass
Required Effective Area 1,810.2 mm² 1,810.23 +0.0019 % Pass
Effective Area of that Orifice 1,841 mm² 1,841 +0.0000 % Pass

Basis: Isentropic choked-nozzle mass flux in SI base units; A = W/(G Kb Kc). Source: Compressible flow through a nozzle (Shapiro, Dynamics and Thermodynamics of Compressible Fluid Flow); API 520 Part I gives the same equation with the constant 0.03948.

Gas, subcritical flow: nitrogen_high_back

Relief Valve Sizing (API 520). Inputs: service = gas, mass_flow = 4,000, set_pressure = 500, overpressure = 10, back_pressure = 330, temperature = 30, molar_mass = 28.01, k = 1.4, z = 1, kd = 0.975.

QuantityReferenceProgramDifferenceResult
Required Effective Area 798.942 mm² 798.489 -0.0567 % Pass
Effective Area of that Orifice 830 mm² 830 +0.0000 % Pass

Basis: Isentropic subcritical nozzle mass flux in SI base units; A = W/(G Kc). Source: Compressible flow through a nozzle (Shapiro); API 520 Part I gives the same equation with 17.9 and F2.

Gas, subcritical flow: steam_like_gas

Relief Valve Sizing (API 520). Inputs: service = gas, mass_flow = 2,500, set_pressure = 900, overpressure = 10, back_pressure = 560, temperature = 150, molar_mass = 18.015, k = 1.3, z = 0.98, kd = 0.975.

QuantityReferenceProgramDifferenceResult
Required Effective Area 431.534 mm² 431.289 -0.0567 % Pass
Effective Area of that Orifice 506 mm² 506 +0.0000 % Pass

Basis: Isentropic subcritical nozzle mass flux in SI base units; A = W/(G Kc). Source: Compressible flow through a nozzle (Shapiro); API 520 Part I gives the same equation with 17.9 and F2.

Liquid: water_fire

Relief Valve Sizing (API 520). Inputs: service = liquid, liquid_flow = 18, specific_gravity = 1, set_pressure = 1,000, overpressure = 10, back_pressure = 0, kd = 0.65, kw = 1, kv = 1, rupture_disk = no.

QuantityReferenceProgramDifferenceResult
Required Effective Area 164.001 mm² 163.929 -0.0436 % Pass
Effective Area of that Orifice 198 mm² 198 +0.0000 % Pass

Basis: Bernoulli through the nozzle: Q = Kd Kw Kc Kv A sqrt(2 dP / rho). Source: Bernoulli equation; API 520 Part I gives the same equation with 11.78.

Liquid: brine_back

Relief Valve Sizing (API 520). Inputs: service = liquid, liquid_flow = 60, specific_gravity = 1.2, set_pressure = 600, overpressure = 21, back_pressure = 120, kd = 0.65, kw = 0.98, kv = 1, rupture_disk = yes.

QuantityReferenceProgramDifferenceResult
Required Effective Area 914.758 mm² 914.361 -0.0434 % Pass
Effective Area of that Orifice 1,186 mm² 1,186 +0.0000 % Pass

Basis: Bernoulli through the nozzle: Q = Kd Kw Kc Kv A sqrt(2 dP / rho). Source: Bernoulli equation; API 520 Part I gives the same equation with 11.78.

Liquid: oil_viscous

Relief Valve Sizing (API 520). Inputs: service = liquid, liquid_flow = 7, specific_gravity = 0.85, set_pressure = 1,800, overpressure = 10, back_pressure = 0, kd = 0.62, kw = 1, kv = 0.8, rupture_disk = no.

QuantityReferenceProgramDifferenceResult
Required Effective Area 57.4349 mm² 57.41 -0.0433 % Pass
Effective Area of that Orifice 71 mm² 71 +0.0000 % Pass

Basis: Bernoulli through the nozzle: Q = Kd Kw Kc Kv A sqrt(2 dP / rho). Source: Bernoulli equation; API 520 Part I gives the same equation with 11.78.

Steam: saturated

Relief Valve Sizing (API 520). Inputs: service = steam, mass_flow = 20,000, set_pressure = 1,000, overpressure = 10, kd = 0.975, kb = 1, kn = 1, ksh = 1, rupture_disk = no.

QuantityReferenceProgramDifferenceResult
Required Effective Area 3,252.82 mm² 3,252.82 +0.0000 % Pass
Effective Area of that Orifice 4,116 mm² 4,116 +0.0000 % Pass

Basis: A = 190.5 W / (P1 Kd Kb Kc Kn Ksh), evaluated by hand (the constant itself is not independently confirmed). Source: API 520 Part I steam equation as recalled by the author; NOT confirmed on a page.

Steam: superheated_disk

Relief Valve Sizing (API 520). Inputs: service = steam, mass_flow = 45,000, set_pressure = 2,500, overpressure = 16, kd = 0.95, kb = 0.97, kn = 1, ksh = 0.88, rupture_disk = yes.

QuantityReferenceProgramDifferenceResult
Required Effective Area 3,913.58 mm² 3,913.58 +0.0000 % Pass
Effective Area of that Orifice 4,116 mm² 4,116 +0.0000 % Pass

Basis: A = 190.5 W / (P1 Kd Kb Kc Kn Ksh), evaluated by hand (the constant itself is not independently confirmed). Source: API 520 Part I steam equation as recalled by the author; NOT confirmed on a page.

Pressure vessel shell and head (ASME VIII-1, internal pressure)

Cylinder and hemispherical head are compared with the thick-wall Lame solutions (the ASME thin-wall equations must be on the safe side and within 1.5 to 2 % up to P = 0.2 S E); the 2:1 ellipsoidal and torispherical heads evaluate the equation by hand. Allowable stress is an input in every case; the values are illustrative, not a material.

Cylinder, low: P = 500 kPa, Di = 2000 mm, S = 138 MPa, E = 1, CA = 0 mm

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = cylinder, design_pressure = 500, inside_diameter = 2,000, allowable_stress = 138, joint_efficiency = 1, corrosion_allowance = 0.

QuantityReferenceProgramDifferenceResult
Required Thickness, Circumferential Stress (cylinder) 3.62978 mm 3.6311 +0.0365 % Pass
Required Thickness, Longitudinal Stress (cylinder) 1.80996 mm 1.8103 +0.0190 % Pass
Required Thickness (corroded condition, before corrosion allowance) 3.62978 mm 3.6311 +0.0365 % Pass

Basis: Thick-wall Lame solution with the stress at the bore set to S E (corroded inside radius). Source: Lame (thick cylinder); Timoshenko, Strength of Materials.

Cylinder, mid: P = 1500 kPa, Di = 1600 mm, S = 138 MPa, E = 0.85, CA = 0 mm

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = cylinder, design_pressure = 1,500, inside_diameter = 1,600, allowable_stress = 138, joint_efficiency = 0.85, corrosion_allowance = 0.

QuantityReferenceProgramDifferenceResult
Required Thickness, Circumferential Stress (cylinder) 10.2964 mm 10.3093 +0.1250 % Pass
Required Thickness, Longitudinal Stress (cylinder) 5.09884 mm 5.102 +0.0620 % Pass
Required Thickness (corroded condition, before corrosion allowance) 10.2964 mm 10.3093 +0.1250 % Pass

Basis: Thick-wall Lame solution with the stress at the bore set to S E (corroded inside radius). Source: Lame (thick cylinder); Timoshenko, Strength of Materials.

Cylinder, high: P = 4000 kPa, Di = 1200 mm, S = 138 MPa, E = 1, CA = 0 mm

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = cylinder, design_pressure = 4,000, inside_diameter = 1,200, allowable_stress = 138, joint_efficiency = 1, corrosion_allowance = 0.

QuantityReferenceProgramDifferenceResult
Required Thickness, Circumferential Stress (cylinder) 17.6508 mm 17.6991 +0.2735 % Pass
Required Thickness, Longitudinal Stress (cylinder) 8.63354 mm 8.6455 +0.1386 % Pass
Required Thickness (corroded condition, before corrosion allowance) 17.6508 mm 17.6991 +0.2735 % Pass

Basis: Thick-wall Lame solution with the stress at the bore set to S E (corroded inside radius). Source: Lame (thick cylinder); Timoshenko, Strength of Materials.

Cylinder, corroded: P = 1000 kPa, Di = 3000 mm, S = 118 MPa, E = 0.85, CA = 3 mm

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = cylinder, design_pressure = 1,000, inside_diameter = 3,000, allowable_stress = 118, joint_efficiency = 0.85, corrosion_allowance = 3.

QuantityReferenceProgramDifferenceResult
Required Thickness, Circumferential Stress (cylinder) 15.0605 mm 15.0752 +0.0976 % Pass
Required Thickness, Longitudinal Stress (cylinder) 7.47394 mm 7.4776 +0.0490 % Pass
Required Thickness (corroded condition, before corrosion allowance) 15.0605 mm 15.0752 +0.0976 % Pass

Basis: Thick-wall Lame solution with the stress at the bore set to S E (corroded inside radius). Source: Lame (thick cylinder); Timoshenko, Strength of Materials.

Cylinder MAWP: Di = 1800 mm, tn = 14 mm, CA = 3 mm

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = cylinder, design_pressure = 500, inside_diameter = 1,800, allowable_stress = 138, joint_efficiency = 0.85, corrosion_allowance = 3, nominal_thickness = 14.

QuantityReferenceProgramDifferenceResult
MAWP, Corroded Condition, at the Nominal Thickness 1,420.2 kPa (g) 1,418.54 -0.1170 % Pass
Shop Hydrostatic Test Pressure, 1.3 × MAWP × Stress Ratio 1,846.26 kPa (g) 1,844.1 -0.1171 % Pass

Basis: Thick-wall Lame solution run backwards (smaller of the hoop and axial limits); hydrotest = 1.3 MAWP. Source: Lame (thick cylinder).

Cylinder MAWP: Di = 900 mm, tn = 10 mm, CA = 1.5 mm

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = cylinder, design_pressure = 500, inside_diameter = 900, allowable_stress = 118, joint_efficiency = 1, corrosion_allowance = 1.5, nominal_thickness = 10.

QuantityReferenceProgramDifferenceResult
MAWP, Corroded Condition, at the Nominal Thickness 2,200.58 kPa (g) 2,196.67 -0.1775 % Pass
Shop Hydrostatic Test Pressure, 1.3 × MAWP × Stress Ratio 2,860.75 kPa (g) 2,855.67 -0.1776 % Pass

Basis: Thick-wall Lame solution run backwards (smaller of the hoop and axial limits); hydrotest = 1.3 MAWP. Source: Lame (thick cylinder).

Hemispherical head: P = 800 kPa, Di = 2400 mm, S = 138, E = 1, CA = 2

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = hemispherical, design_pressure = 800, inside_diameter = 2,400, allowable_stress = 138, joint_efficiency = 1, corrosion_allowance = 2.

QuantityReferenceProgramDifferenceResult
Required Thickness (corroded condition, before corrosion allowance) 3.48408 mm 3.4861 +0.0581 % Pass

Basis: Thick-sphere Lame solution with the stress at the bore set to S E. Source: Lame (thick sphere); Timoshenko.

Hemispherical head: P = 2500 kPa, Di = 1000 mm, S = 118, E = 0.85, CA = 0

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = hemispherical, design_pressure = 2,500, inside_diameter = 1,000, allowable_stress = 118, joint_efficiency = 0.85, corrosion_allowance = 0.

QuantityReferenceProgramDifferenceResult
Required Thickness (corroded condition, before corrosion allowance) 6.23195 mm 6.2469 +0.2399 % Pass

Basis: Thick-sphere Lame solution with the stress at the bore set to S E. Source: Lame (thick sphere); Timoshenko.

2:1 ellipsoidal head: P = 1000 kPa, Di = 2200 mm, S = 138, E = 1, CA = 3

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = ellipsoidal, design_pressure = 1,000, inside_diameter = 2,200, allowable_stress = 138, joint_efficiency = 1, corrosion_allowance = 3.

QuantityReferenceProgramDifferenceResult
Required Thickness (corroded condition, before corrosion allowance) 7.99855 mm 7.9985 -0.0006 % Pass

Basis: t = P D / (2 S E - 0.2 P), evaluated by hand (no independent reference). Source: ASME VIII-1 UG-32(d) as recalled by the author: NOT independently checked.

2:1 ellipsoidal head: P = 300 kPa, Di = 3000 mm, S = 118, E = 0.85, CA = 0

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = ellipsoidal, design_pressure = 300, inside_diameter = 3,000, allowable_stress = 118, joint_efficiency = 0.85, corrosion_allowance = 0.

QuantityReferenceProgramDifferenceResult
Required Thickness (corroded condition, before corrosion allowance) 4.48788 mm 4.4879 +0.0004 % Pass

Basis: t = P D / (2 S E - 0.2 P), evaluated by hand (no independent reference). Source: ASME VIII-1 UG-32(d) as recalled by the author: NOT independently checked.

Torispherical head: P = 700 kPa, L = 2000 mm, r = 120 mm, S = 138, E = 1, CA = 2

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = torispherical, design_pressure = 700, inside_diameter = 2,000, crown_radius = 2,000, knuckle_radius = 120, allowable_stress = 138, joint_efficiency = 1, corrosion_allowance = 2.

QuantityReferenceProgramDifferenceResult
Required Thickness (corroded condition, before corrosion allowance) 8.95485 mm 8.9548 -0.0006 % Pass

Basis: t = P L M / (2 S E - 0.2 P), M = 1/4 (3 + sqrt(L/r)), evaluated by hand (no independent reference). Source: ASME VIII-1 UG-32(e) / Appendix 1-4(d) as recalled; M expression seen in an LBNL worksheet extract: NOT independently checked.

Torispherical head: P = 1500 kPa, L = 1350 mm, r = 150 mm, S = 118, E = 0.85, CA = 0

Pressure Vessel Shell and Head (ASME VIII-1). Inputs: component = torispherical, design_pressure = 1,500, inside_diameter = 1,500, crown_radius = 1,350, knuckle_radius = 150, allowable_stress = 118, joint_efficiency = 0.85, corrosion_allowance = 0.

QuantityReferenceProgramDifferenceResult
Required Thickness (corroded condition, before corrosion allowance) 15.1648 mm 15.1648 +0.0003 % Pass

Basis: t = P L M / (2 S E - 0.2 P), M = 1/4 (3 + sqrt(L/r)), evaluated by hand (no independent reference). Source: ASME VIII-1 UG-32(e) / Appendix 1-4(d) as recalled; M expression seen in an LBNL worksheet extract: NOT independently checked.

Heat exchanger, gas compression and fan power

Heat exchanger area (LMTD with the 1-2 shell correction factor F) against the effectiveness-NTU method; compression power and discharge temperature against numerical integration of the work along the isentropic or polytropic path, stage by stage; fan power and the fan laws against closed arithmetic (code and units only).

Heat exchanger counter: hot 50000 kg/h 90 to 60 C, cold from 20 C, U = 800

Heat Exchanger Sizing (LMTD). Inputs: arrangement = counter, hot_flow = 50,000, hot_cp = 4.18, hot_in = 90, hot_out = 60, cold_in = 20, cold_cp = 4.18, u = 800, margin = 0, cold_out = 45.

QuantityReferenceProgramDifferenceResult
Heat Duty 1,741.67 kW 1,741.67 +0.0000 % Pass
Cold Side Outlet Temperature 45 °C 45 +0.0000 % Pass
Required Area 51.2847 m² 51.2847 +0.0000 % Pass
NTU 0.706698 0.7067 +0.0003 % Pass
Effectiveness 0.428571 0.4286 +0.0067 % Pass

Basis: Area = NTU Cmin / U with NTU from the effectiveness-NTU relation of the arrangement (a different formulation from LMTD x F). Source: Kays and London, Compact Heat Exchangers (1984), as recalled; the block uses LMTD and the Bowman F (not read on a page).

Heat exchanger counter: hot 30000 kg/h 140 to 80 C, cold from 25 C, U = 450

Heat Exchanger Sizing (LMTD). Inputs: arrangement = counter, hot_flow = 30,000, hot_cp = 3, hot_in = 140, hot_out = 80, cold_in = 25, cold_cp = 4.18, u = 450, margin = 0, cold_flow = 40,000.

QuantityReferenceProgramDifferenceResult
Heat Duty 1,500 kW 1,500 +0.0000 % Pass
Cold Side Outlet Temperature 57.2967 °C 57.297 +0.0006 % Pass
Required Area 49.0827 m² 49.0827 -0.0001 % Pass
NTU 0.883489 0.8835 +0.0012 % Pass
Effectiveness 0.521739 0.5217 -0.0075 % Pass

Basis: Area = NTU Cmin / U with NTU from the effectiveness-NTU relation of the arrangement (a different formulation from LMTD x F). Source: Kays and London, Compact Heat Exchangers (1984), as recalled; the block uses LMTD and the Bowman F (not read on a page).

Heat exchanger parallel: hot 40000 kg/h 95 to 65 C, cold from 15 C, U = 600

Heat Exchanger Sizing (LMTD). Inputs: arrangement = parallel, hot_flow = 40,000, hot_cp = 4.18, hot_in = 95, hot_out = 65, cold_in = 15, cold_cp = 4.18, u = 600, margin = 0, cold_out = 50.

QuantityReferenceProgramDifferenceResult
Heat Duty 1,393.33 kW 1,393.33 0.0000 % Pass
Cold Side Outlet Temperature 50 °C 50 +0.0000 % Pass
Required Area 59.8053 m² 59.8053 0.0000 % Pass
NTU 0.901372 0.9014 +0.0031 % Pass
Effectiveness 0.4375 0.4375 +0.0000 % Pass

Basis: Area = NTU Cmin / U with NTU from the effectiveness-NTU relation of the arrangement (a different formulation from LMTD x F). Source: Kays and London, Compact Heat Exchangers (1984), as recalled; the block uses LMTD and the Bowman F (not read on a page).

Heat exchanger shell_2pass: hot 60000 kg/h 150 to 90 C, cold from 30 C, U = 350

Heat Exchanger Sizing (LMTD). Inputs: arrangement = shell_2pass, hot_flow = 60,000, hot_cp = 2.2, hot_in = 150, hot_out = 90, cold_in = 30, cold_cp = 4.18, u = 350, margin = 0, cold_out = 70.

QuantityReferenceProgramDifferenceResult
Heat Duty 2,200 kW 2,200 0.0000 % Pass
Cold Side Outlet Temperature 70 °C 70 +0.0000 % Pass
Required Area 99.304 m² 99.304 +0.0000 % Pass
NTU 0.947902 0.9479 -0.0002 % Pass
Effectiveness 0.5 0.5 +0.0000 % Pass

Basis: Area = NTU Cmin / U with NTU from the effectiveness-NTU relation of the arrangement (a different formulation from LMTD x F). Source: Kays and London, Compact Heat Exchangers (1984), as recalled; the block uses LMTD and the Bowman F (not read on a page).

Heat exchanger shell_2pass: hot 36000 kg/h 80 to 60 C, cold from 25 C, U = 900

Heat Exchanger Sizing (LMTD). Inputs: arrangement = shell_2pass, hot_flow = 36,000, hot_cp = 4.18, hot_in = 80, hot_out = 60, cold_in = 25, cold_cp = 4.18, u = 900, margin = 0, cold_out = 45.

QuantityReferenceProgramDifferenceResult
Heat Duty 836 kW 836 +0.0000 % Pass
Cold Side Outlet Temperature 45 °C 45 +0.0000 % Pass
Required Area 28.1444 m² 28.1444 -0.0001 % Pass
NTU 0.60598 0.606 +0.0032 % Pass
Effectiveness 0.363636 0.3636 -0.0100 % Pass

Basis: Area = NTU Cmin / U with NTU from the effectiveness-NTU relation of the arrangement (a different formulation from LMTD x F). Source: Kays and London, Compact Heat Exchangers (1984), as recalled; the block uses LMTD and the Bowman F (not read on a page).

Heat exchanger shell_2pass: hot 25000 kg/h 200 to 120 C, cold from 40 C, U = 300

Heat Exchanger Sizing (LMTD). Inputs: arrangement = shell_2pass, hot_flow = 25,000, hot_cp = 2, hot_in = 200, hot_out = 120, cold_in = 40, cold_cp = 4.18, u = 300, margin = 0, cold_flow = 18,000.

QuantityReferenceProgramDifferenceResult
Heat Duty 1,111.11 kW 1,111.11 0.0000 % Pass
Cold Side Outlet Temperature 93.1632 °C 93.163 -0.0002 % Pass
Required Area 43.8253 m² 43.8253 +0.0000 % Pass
NTU 0.946626 0.9466 -0.0028 % Pass
Effectiveness 0.5 0.5 +0.0000 % Pass

Basis: Area = NTU Cmin / U with NTU from the effectiveness-NTU relation of the arrangement (a different formulation from LMTD x F). Source: Kays and London, Compact Heat Exchangers (1984), as recalled; the block uses LMTD and the Bowman F (not read on a page).

Heat exchanger: U from film coefficients, fouling and wall

Heat Exchanger Sizing (LMTD). Inputs: arrangement = counter, hot_flow = 50,000, hot_cp = 4.18, hot_in = 90, hot_out = 60, cold_in = 20, cold_cp = 4.18, cold_out = 45, h_hot = 1,500, h_cold = 900, fouling_hot = 0.0002, fouling_cold = 0.0004, wall_thickness = 2, wall_conductivity = 45, margin = 0.

QuantityReferenceProgramDifferenceResult
Overall Coefficient Used 412.844 W/(m²·K) 412.844 0.0000 % Pass
Required Area 99.3783 m² 99.3783 0.0000 % Pass

Basis: 1/U = 1/h1 + Rf1 + t/k + Rf2 + 1/h2; area by the effectiveness-NTU method. Source: Series thermal resistances (textbook).

Gas compression air_1stage_is: 3000 m3/h, 101.325 to 400 kPa, 1 stage(s)

Gas Compression Power. Inputs: flow = 3,000, inlet_pressure = 101.325, inlet_temperature = 25, outlet_pressure = 400, molar_mass = 28.96, k = 1.4, z = 1, efficiency_basis = isentropic, efficiency = 78, mechanical_efficiency = 96, stages = 1.

QuantityReferenceProgramDifferenceResult
Mass Flow 3,551.14 kg/h 3,551.14 +0.0000 % Pass
Gas Power 141.978 kW 141.978 +0.0000 % Pass
Shaft Power Absorbed 189.607 kW 189.607 -0.0002 % Pass
Discharge Temperature (last stage) 208.636 °C 208.64 +0.0019 % Pass
Overall Pressure Ratio 3.94769 3.9477 +0.0002 % Pass

Basis: Numerical integration (Simpson) of the work v dP along the isentropic or polytropic path, per stage with the intercooler. Source: Ideal-gas compression thermodynamics (any thermodynamics text); the block uses the closed forms.

Gas compression air_2stage_ic: 3000 m3/h, 101.325 to 900 kPa, 2 stage(s)

Gas Compression Power. Inputs: flow = 3,000, inlet_pressure = 101.325, inlet_temperature = 25, outlet_pressure = 900, molar_mass = 28.96, k = 1.4, z = 1, efficiency_basis = isentropic, efficiency = 75, mechanical_efficiency = 95, stages = 2, intercooler_temperature = 35.

QuantityReferenceProgramDifferenceResult
Mass Flow 3,551.14 kg/h 3,551.14 +0.0000 % Pass
Gas Power 220.057 kW 220.057 +0.0000 % Pass
Shaft Power Absorbed 308.852 kW 308.852 +0.0001 % Pass
Discharge Temperature (last stage) 185.446 °C 185.45 +0.0023 % Pass
Overall Pressure Ratio 8.88231 8.8823 -0.0001 % Pass

Basis: Numerical integration (Simpson) of the work v dP along the isentropic or polytropic path, per stage with the intercooler. Source: Ideal-gas compression thermodynamics (any thermodynamics text); the block uses the closed forms.

Gas compression methane_poly: 8000 m3/h, 2000 to 7000 kPa, 1 stage(s)

Gas Compression Power. Inputs: flow = 8,000, inlet_pressure = 2,000, inlet_temperature = 30, outlet_pressure = 7,000, molar_mass = 16.04, k = 1.31, z = 0.92, efficiency_basis = polytropic, efficiency = 80, mechanical_efficiency = 97, stages = 1.

QuantityReferenceProgramDifferenceResult
Mass Flow 110,674 kg/h 110,674 +0.0000 % Pass
Gas Power 6,739.64 kW 6,739.64 +0.0000 % Pass
Shaft Power Absorbed 8,685.1 kW 8,685.1 0.0000 % Pass
Discharge Temperature (last stage) 165.981 °C 165.98 -0.0004 % Pass
Overall Pressure Ratio 3.5 3.5 +0.0000 % Pass

Basis: Numerical integration (Simpson) of the work v dP along the isentropic or polytropic path, per stage with the intercooler. Source: Ideal-gas compression thermodynamics (any thermodynamics text); the block uses the closed forms.

Gas compression hydrogen_3stage: 1200 m3/h, 500 to 9000 kPa, 3 stage(s)

Gas Compression Power. Inputs: flow = 1,200, inlet_pressure = 500, inlet_temperature = 20, outlet_pressure = 9,000, molar_mass = 2.016, k = 1.41, z = 1, efficiency_basis = polytropic, efficiency = 72, mechanical_efficiency = 95, stages = 3, intercooler_temperature = 40.

QuantityReferenceProgramDifferenceResult
Mass Flow 496.27 kg/h 496.27 +0.0001 % Pass
Gas Power 615.67 kW 615.67 -0.0001 % Pass
Shaft Power Absorbed 900.103 kW 900.103 0.0000 % Pass
Discharge Temperature (last stage) 188.952 °C 188.95 -0.0010 % Pass
Overall Pressure Ratio 18 18 +0.0000 % Pass

Basis: Numerical integration (Simpson) of the work v dP along the isentropic or polytropic path, per stage with the intercooler. Source: Ideal-gas compression thermodynamics (any thermodynamics text); the block uses the closed forms.

Fan air_ambient: 20000 m3/h, 1.2 kPa, 20 C

Fan / Blower Power. Inputs: flow = 20,000, pressure_rise = 1.2, inlet_pressure = 101.325, temperature = 20, molar_mass = 28.96, efficiency = 72, drive_efficiency = 95.

QuantityReferenceProgramDifferenceResult
Gas Density 1.2039 kg/m³ 1.2039 -0.0002 % Pass
Mass Flow 24,078 kg/h 24,078 0.0000 % Pass
Gas Power 6.66667 kW 6.6667 +0.0005 % Pass
Shaft Power Absorbed 9.25926 kW 9.2593 +0.0004 % Pass
Power at the Drive Input 9.74659 kW 9.7466 +0.0001 % Pass

Basis: rho = P M / (R T); gas power = Q dP; shaft = gas / eta; fan laws N, N^2, N^3. Source: Fan engineering relations (textbook); the code and units are what is tested.

Fan hot_gas_speed: 60000 m3/h, 3 kPa, 180 C

Fan / Blower Power. Inputs: flow = 60,000, pressure_rise = 3, inlet_pressure = 98, temperature = 180, molar_mass = 29.5, efficiency = 80, drive_efficiency = 100, speed_ratio = 0.85.

QuantityReferenceProgramDifferenceResult
Gas Density 0.767312 kg/m³ 0.76731 -0.0002 % Pass
Mass Flow 46,038.7 kg/h 46,038.7 +0.0000 % Pass
Gas Power 50 kW 50 +0.0000 % Pass
Shaft Power Absorbed 62.5 kW 62.5 +0.0000 % Pass
Power at the Drive Input 62.5 kW 62.5 +0.0000 % Pass
Flow at the New Speed 51,000 m³/h 51,000 +0.0000 % Pass
Total Pressure Rise at the New Speed 2.1675 kPa 2.1675 +0.0000 % Pass
Shaft Power at the New Speed 38.3828 kW 38.3828 0.0000 % Pass

Basis: rho = P M / (R T); gas power = Q dP; shaft = gas / eta; fan laws N, N^2, N^3. Source: Fan engineering relations (textbook); the code and units are what is tested.

Belt conveyor, bin, agitator and screen

Belt load cross-section (polygon plus numerically integrated surcharge segment), bin volumes (numerical integration along the height) and Janssen pressure (RK4 of the force balance) are checked against independent numerical references; conveyor resistances, agitator power and screen area are closed arithmetic (they test the code and the units, not the engineering).

Belt load section: B = 1200 mm, trough 35, surcharge 20, v = 2.5 m/s, rho = 1600

Belt Conveyor Capacity and Power. Inputs: belt_width = 1,200, trough_angle = 35, surcharge_angle = 20, centre_fraction = 0.4, speed = 2.5, bulk_density = 1,600.

QuantityReferenceProgramDifferenceResult
Loaded Width 1,030 mm 1,030 +0.0000 % Pass
Cross-Section Area of the Load 0.162453 m² 0.162453 +0.0002 % Pass
Capacity (full section) 2,339.32 t/h 2,339.32 +0.0000 % Pass

Basis: Polygon (shoelace) of the trough plus the numerically integrated circular surcharge segment; Q = 3.6 A v rho / 1000. Source: Plane geometry; belt conveyor load section (ISO 5048 / CEMA describe the same section).

Belt load section: B = 800 mm, trough 0, surcharge 15, v = 1.6 m/s, rho = 1200

Belt Conveyor Capacity and Power. Inputs: belt_width = 800, trough_angle = 0, surcharge_angle = 15, centre_fraction = 0.4, speed = 1.6, bulk_density = 1,200.

QuantityReferenceProgramDifferenceResult
Loaded Width 670 mm 670 +0.0000 % Pass
Cross-Section Area of the Load 0.0197677 m² 0.019768 +0.0014 % Pass
Capacity (full section) 136.634 t/h 136.63 -0.0033 % Pass

Basis: Polygon (shoelace) of the trough plus the numerically integrated circular surcharge segment; Q = 3.6 A v rho / 1000. Source: Plane geometry; belt conveyor load section (ISO 5048 / CEMA describe the same section).

Belt load section: B = 1800 mm, trough 45, surcharge 25, v = 3.15 m/s, rho = 2000

Belt Conveyor Capacity and Power. Inputs: belt_width = 1,800, trough_angle = 45, surcharge_angle = 25, centre_fraction = 0.35, speed = 3.15, bulk_density = 2,000.

QuantityReferenceProgramDifferenceResult
Loaded Width 1,570 mm 1,570 +0.0000 % Pass
Cross-Section Area of the Load 0.444901 m² 0.444901 -0.0001 % Pass
Capacity (full section) 10,090.4 t/h 10,090.4 +0.0000 % Pass

Basis: Polygon (shoelace) of the trough plus the numerically integrated circular surcharge segment; Q = 3.6 A v rho / 1000. Source: Plane geometry; belt conveyor load section (ISO 5048 / CEMA describe the same section).

Belt power: L = 450 m, lift 25 m, f = 0.022, 600 t/h

Belt Conveyor Capacity and Power. Inputs: belt_width = 1,200, trough_angle = 35, surcharge_angle = 20, centre_fraction = 0.4, speed = 2.5, bulk_density = 1,600, design_flow = 600, length = 450, lift = 25, friction_factor = 0.022, belt_mass = 18, idler_mass = 28, secondary = 15, drive_efficiency = 95.

QuantityReferenceProgramDifferenceResult
Load on the Belt 66.6667 kg/m 66.667 +0.0005 % Pass
Main Resistance 12.6705 kN 12.6705 +0.0001 % Pass
Lift Force 16.3444 kN 16.3444 -0.0001 % Pass
Effective Tension 30.9155 kN 30.9155 +0.0001 % Pass
Power at the Drive Pulley 77.2887 kW 77.289 +0.0004 % Pass
Absorbed Power at the Motor Shaft 81.3565 kW 81.357 +0.0006 % Pass

Basis: F_H = f L g [m_R + (2 m_B + m_G) cos delta], F_St = m_G g H, F_N = 15 % of F_H, P = F v: closed arithmetic (the expression itself is not confirmed against the standard). Source: ISO 5048 / DIN 22101 resistance form as recalled; f is an input.

Bin round: size 6 m, H = 9 m, outlet 0.8 m, alpha 30

Bin / Hopper Volume and Retention. Inputs: shape = round, size = 6, height = 9, outlet = 0.8, half_angle = 30, fill_factor = 85, bulk_density = 1,500, throughput = 120, wall_friction = 0.35, k_ratio = 0.45.

QuantityReferenceProgramDifferenceResult
Hopper Height 4.50333 m 4.5033 -0.0007 % Pass
Volume of the Vertical Part 254.469 m³ 254.469 0.0000 % Pass
Volume of the Hopper 48.8565 m³ 48.8565 +0.0000 % Pass
Total Geometric Volume 303.326 m³ 303.326 0.0000 % Pass
Mass Held (usable) 386.74 t 386.74 0.0000 % Pass
Retention Time at the Throughput 3.22283 h 3.2228 -0.0010 % Pass
Janssen Vertical Pressure 85.6429 kPa 85.6429 0.0000 % Pass
Janssen Horizontal Pressure 38.5393 kPa 38.5393 -0.0001 % Pass

Basis: Volumes integrated numerically along the height (Simpson); Janssen pressure from the RK4 integration of dp/dz = rho g - mu K p / R (R = D/4). Source: Solid geometry; Janssen (1895) force balance.

Bin square: size 4 m, H = 6 m, outlet 0.6 m, alpha 35

Bin / Hopper Volume and Retention. Inputs: shape = square, size = 4, height = 6, outlet = 0.6, half_angle = 35, fill_factor = 90, bulk_density = 900, throughput = 40, wall_friction = 0.3, k_ratio = 0.5.

QuantityReferenceProgramDifferenceResult
Hopper Height 2.42785 m 2.4279 +0.0020 % Pass
Volume of the Vertical Part 96 m³ 96 +0.0000 % Pass
Volume of the Hopper 15.1822 m³ 15.1822 +0.0002 % Pass
Total Geometric Volume 111.182 m³ 111.182 +0.0000 % Pass
Mass Held (usable) 90.0576 t 90.0576 +0.0001 % Pass
Retention Time at the Throughput 2.25144 h 2.2514 -0.0017 % Pass
Janssen Vertical Pressure 34.9174 kPa 34.9174 +0.0001 % Pass
Janssen Horizontal Pressure 17.4587 kPa 17.4587 +0.0001 % Pass

Basis: Volumes integrated numerically along the height (Simpson); Janssen pressure from the RK4 integration of dp/dz = rho g - mu K p / R (R = D/4). Source: Solid geometry; Janssen (1895) force balance.

Bin round: size 3.2 m, H = 2 m, outlet 0.5 m, alpha 20

Bin / Hopper Volume and Retention. Inputs: shape = round, size = 3.2, height = 2, outlet = 0.5, half_angle = 20, fill_factor = 80, bulk_density = 2,200, throughput = 15, wall_friction = 0.5, k_ratio = 0.4.

QuantityReferenceProgramDifferenceResult
Hopper Height 3.70909 m 3.7091 +0.0001 % Pass
Volume of the Vertical Part 16.085 m³ 16.085 +0.0003 % Pass
Volume of the Hopper 11.7399 m³ 11.7399 +0.0004 % Pass
Total Geometric Volume 27.8248 m³ 27.8248 0.0000 % Pass
Mass Held (usable) 48.9717 t 48.9717 +0.0001 % Pass
Retention Time at the Throughput 3.26478 h 3.2648 +0.0007 % Pass
Janssen Vertical Pressure 33.9558 kPa 33.9558 -0.0001 % Pass
Janssen Horizontal Pressure 13.5823 kPa 13.5823 -0.0002 % Pass

Basis: Volumes integrated numerically along the height (Simpson); Janssen pressure from the RK4 integration of dp/dz = rho g - mu K p / R (R = D/4). Source: Solid geometry; Janssen (1895) force balance.

Agitator pitched_water: D = 1.2 m, 90 rpm, rho = 1000, mu = 1 mPa.s

Agitator Power. Inputs: impeller = pitched, impeller_diameter = 1.2, speed = 90, density = 1,000, viscosity = 1, tank_diameter = 3.6, liquid_height = 3.6, mechanical_efficiency = 95.

QuantityReferenceProgramDifferenceResult
Power Number Used 1.3 1.3 +0.0000 % Pass
Impeller Reynolds Number 2,160,000 2,160,000 +0.0000 % Pass
Power Drawn by the Impeller 10.9175 kW 10.9175 0.0000 % Pass
Absorbed Power at the Motor Shaft 11.4921 kW 11.4921 -0.0001 % Pass
Impeller Tip Speed 5.65487 m/s 5.655 +0.0024 % Pass
Power per Volume 0.297938 kW/m³ 0.297938 0.0000 % Pass

Basis: P = Np rho N^3 D^5, Re = rho N D^2 / mu: closed arithmetic (the typical Np values are not the test). Source: Agitator power number definition; typical Np values from search extracts.

Agitator rushton_slurry: D = 0.9 m, 120 rpm, rho = 1350, mu = 40 mPa.s

Agitator Power. Inputs: impeller = rushton, impeller_diameter = 0.9, speed = 120, density = 1,350, viscosity = 40, tank_diameter = 2.7, liquid_height = 2.9, mechanical_efficiency = 95.

QuantityReferenceProgramDifferenceResult
Power Number Used 5 5 +0.0000 % Pass
Impeller Reynolds Number 54,675 54,675 +0.0000 % Pass
Power Drawn by the Impeller 31.8865 kW 31.8865 +0.0001 % Pass
Absorbed Power at the Motor Shaft 33.5647 kW 33.5647 +0.0000 % Pass
Impeller Tip Speed 5.65487 m/s 5.655 +0.0024 % Pass
Power per Volume 1.9204 kW/m³ 1.9204 0.0000 % Pass

Basis: P = Np rho N^3 D^5, Re = rho N D^2 / mu: closed arithmetic (the typical Np values are not the test). Source: Agitator power number definition; typical Np values from search extracts.

Agitator own_np: D = 2 m, 45 rpm, rho = 1100, mu = 5 mPa.s

Agitator Power. Inputs: impeller = own, impeller_diameter = 2, speed = 45, density = 1,100, viscosity = 5, tank_diameter = 6, liquid_height = 6.5, mechanical_efficiency = 95, np = 0.75.

QuantityReferenceProgramDifferenceResult
Power Number Used 0.75 0.75 +0.0000 % Pass
Impeller Reynolds Number 660,000 660,000 +0.0000 % Pass
Power Drawn by the Impeller 11.1375 kW 11.1375 +0.0000 % Pass
Absorbed Power at the Motor Shaft 11.7237 kW 11.7237 +0.0001 % Pass
Impeller Tip Speed 4.71239 m/s 4.712 -0.0083 % Pass
Power per Volume 0.0606013 kW/m³ 0.060601 -0.0005 % Pass

Basis: P = Np rho N^3 D^5, Re = rho N D^2 / mu: closed arithmetic (the typical Np values are not the test). Source: Agitator power number definition; typical Np values from search extracts.

Screen area plain: 250 t/h, q0 = 38

Screen Area (capacity factors). Inputs: feed = 250, basic_capacity = 38, length_to_width = 2.5, margin = 10.

QuantityReferenceProgramDifferenceResult
Product of the Correction Factors 1 1 +0.0000 % Pass
Required Deck Area 6.57895 m² 6.5789 -0.0007 % Pass
Deck Area with Margin 7.23684 m² 7.2368 -0.0006 % Pass
Deck Width (with margin) 1.70139 m 1.7014 +0.0004 % Pass
Deck Length (with margin) 4.25348 m 4.2535 +0.0004 % Pass

Basis: A = Q / (q0 K1 K2 ...), width = sqrt(A (1 + margin) / ratio): closed arithmetic. Source: Capacity-factor method (inputs are the maker's data).

Screen area factors: 420 t/h, q0 = 52

Screen Area (capacity factors). Inputs: feed = 420, basic_capacity = 52, length_to_width = 3, margin = 15, k_oversize = 1.05, k_halfsize = 0.9, k_deck = 0.85, k_wet = 1.3, k_density = 1.2.

QuantityReferenceProgramDifferenceResult
Product of the Correction Factors 1.25307 1.25307 +0.0000 % Pass
Required Deck Area 6.44571 m² 6.4457 -0.0001 % Pass
Deck Area with Margin 7.41256 m² 7.4126 +0.0005 % Pass
Deck Width (with margin) 1.5719 m 1.5719 +0.0003 % Pass
Deck Length (with margin) 4.71569 m 4.7157 +0.0003 % Pass

Basis: A = Q / (q0 K1 K2 ...), width = sqrt(A (1 + margin) / ratio): closed arithmetic. Source: Capacity-factor method (inputs are the maker's data).

Differences are shown as (program - reference) / reference. Report generated 2026-11-25 by the verification suite of the Calculations module (php artisan calculations:verify).