Biogas to Power (overview)

Biogas is dried, cleaned and burned in a gas engine to make power and heat.

Loading the animation…
You are watching a free lesson. A free account saves your progress and lets you mark lessons complete. Create a free account Sign in

What a biogas to power plant does

Rotting organic matter gives off a gas that burns. If it is simply released, the methane in it warms the climate, and if it is burned in an engine it makes electricity and heat. A biogas to power plant gathers that gas from a digester or from a landfill, cleans it, burns it in an engine that turns a generator, and sends the power to the grid. The heat from the engine is used too, and often keeps the digester warm.

The gas must be cleaned first because it is wet and carries hydrogen sulphide, which turns into acid and ruins an engine. The gas train is the same kind of equipment you meet on a gas gathering system: separation, cooling, a blower or compressor, a flare for surplus gas. In the animation the digester and the flare are clickable and open their own lessons. The digester is cut open and the landfill is drawn with its two gas wells, so you can see where the gas comes from.

How it works

Follow the olive green biogas line from the sources on the left to the engine, then the yellow power cables to the grid. The orange hot water loop returns heat to the digester.

  1. 1Gas collection. The gas comes from one of two places. In a digester (drawn on the left, cut open) bacteria break down sewage sludge, manure or food waste in a sealed, warm tank, and the gas collects under the roof. At a landfill, gas wells (slotted pipes set into the waste) draw the gas out, and a header pipe joins them. Biogas from a digester is typically about 55 to 65 percent methane and 35 to 45 percent carbon dioxide; landfill gas typically has about 45 to 55 percent methane. Both leave wet, and carry a little hydrogen sulphide (H2S), typically from tens to a few thousand parts per million. At a landfill the blower of step 4 holds the wells under a slight suction; too much suction pulls air into the waste and the pipe, which thins the gas and can make it unsafe.
  2. 2Moisture removal. The gas leaves the digester warm (typically about 35 °C) and saturated with water vapour. Wet gas corrodes pipes, and with hydrogen sulphide it makes acid, so the water is taken out first. The gas passes through a gas chiller, a shell and tube cooler with cold water in the tubes, and is cooled to typically about 5 °C. Most of the water vapour condenses on the cold tubes, runs down into a condensate pot and drains away through a water seal that stops gas escaping. Often the gas is then warmed a few degrees, so that it is no longer saturated and does not form water again in the pipes (the warmer is not drawn).
  3. 3Hydrogen sulphide removal. Hydrogen sulphide is toxic, and when burned it turns into sulphur dioxide, which with water makes acids that attack the engine and its oil. The gas passes through vessels of media that take the hydrogen sulphide out: iron oxide pellets or activated carbon are common (some plants use biological or chemical methods instead). The drawing has two vessels in series. The first is the lead vessel and does most of the work; when its media is used up it is changed and the second vessel takes the lead (the lag vessel). The gas is typically cleaned to below a few hundred parts per million; the engine maker sets the limit.
  4. 4Blower and flare. A gas blower raises the gas pressure slightly, typically by a few tens to a few hundred millibar, so that the gas flows through the cleaning vessels and reaches the engine at the pressure it needs. It is a low pressure machine, a cousin of the gas compressor and the piston compressors that lift gas on a gathering system (compare the coal seam gas lesson, where gas is also gathered from wells). A branch with a valve leads to the flare. The flare burns any gas the engine cannot take, for example when the engine is stopped, so that methane, a strong greenhouse gas, is not released to the air.
  5. 5Gas engine and generator. The engine stands in a container (cut open in the drawing) with the generator on the same base. The gas is mixed with air, drawn into the cylinders and ignited by a spark (some engines use a small amount of liquid fuel to ignite it). The engine turns the generator, an alternator, through a coupling. The speed fixes the frequency: frequency = number of poles × speed (rev/min) ÷ 120, so a four-pole machine at 1,500 rev/min gives 50 Hz (and at 1,800 rev/min 60 Hz). A typical gas engine turns about 35 to 42 percent of the fuel energy into electricity.
  6. 6Heat recovery. An engine does not turn all the fuel into power. Typically about 40 to 50 percent of the fuel energy can be recovered as heat: roughly half from the cooling water jacket and the oil cooler, and roughly half from the hot exhaust, typically about 450 to 550 °C. The exhaust passes up through the tubes of a heat exchanger (a window shows them) that heats water, typically to about 80 to 90 °C, and leaves by the stack, typically at about 120 to 180 °C so that acid does not condense inside. The hot water goes round a loop. At a digester a coil in the tank uses it to hold the contents warm (typically about 35 to 38 °C); any surplus can heat buildings or a process. Making power and heat together is called combined heat and power (CHP).
  7. 7Grid connection. The generator voltage (typically 400 to 690 V) goes to a transformer that raises it to the voltage of the local network (typically 11 or 22 kV, but it varies by place), and a line on poles carries it to the network. A circuit breaker and protection relays, not drawn, connect and disconnect the plant. Before the breaker closes, the generator must be synchronised: its voltage, frequency and phase must match the network. If the network fails, the protection disconnects the plant so that it does not feed a dead line.

The numbers

Typical features: biogas has an energy content of about 6 kWh per cubic metre at 60 percent methane (the lower heating value of methane is about 10 kWh per cubic metre). A gas engine typically converts about 35 to 42 percent of this to electricity and about 40 to 50 percent can be recovered as heat, so heat and power together reach typically 80 to 90 percent. Engines range from tens of kilowatts to a few megawatts.

Worked example. Assume a plant with 500 normal cubic metres of biogas an hour at 60 percent methane, 10 kWh for each cubic metre of methane, a gas at 35 °C chilled to 5 °C (it holds about 40 and 7 g of water in each cubic metre at those temperatures), hydrogen sulphide cleaned from 1,500 to 150 parts per million by volume (the gas has a density of 1.52 kg/m³), media that takes up 0.2 kg of hydrogen sulphide for each kilogram, a blower raising the pressure by 150 mbar at 50 percent efficiency, an engine and generator with an electrical efficiency of 40 percent, recoverable heat of 45 percent of the fuel, 5 percent of the output used by the plant, 8,000 running hours a year, and a digester that needs 300 kW of heat. Volume changes with temperature and pressure are ignored.

QuantityWorkingResult
Methane in the gas500 × 0.60300 m³/h
Fuel power (10 kWh per m³ of methane)300 × 103,000 kW (about 6 kWh per m³ of biogas)
Water to remove: from about 40 to 7 g/m³ (33 g/m³)33 × 500 = 16,500 g/habout 16.5 kg/h, about 400 kg a day
Hydrogen sulphide to remove: 1,500 − 150 = 1,350 ppm0.00135 × 500 = 0.675 m³/h; × 1.52 kg/m³about 1.03 kg/h, about 25 kg a day
Media used up (0.2 kg of H2S per kg of media)24.6 ÷ 0.2about 123 kg a day, about 3.7 tonnes in 30 days
Blower air power (150 mbar = 15,000 Pa)(500 ÷ 3,600) × 15,000about 2,083 W, 2.1 kW
Blower shaft power (50 percent efficient)2.1 ÷ 0.50about 4.2 kW
Generator output (40 percent efficiency)3,000 × 0.401,200 kW
Own use of the plant (blower, chiller, pumps, mixers: 5 percent)1,200 × 0.0560 kW, so 1,140 kW is exported
Recoverable heat (45 percent of the fuel)3,000 × 0.451,350 kW
Heat and power together(1,200 + 1,350) ÷ 3,0000.85, about 85 percent
Digester heating (assume 300 kW), surplus heat1,350 − 3001,050 kW for other uses
Electricity exported in a year (8,000 hours)1,140 × 8,0009,120,000 kWh, about 9.1 GWh
Frequency of a four-pole generator at 1,500 rev/min4 × 1,500 ÷ 12050 Hz

The numbers show where the energy goes. Of 3,000 kW in the gas, about 1,200 kW leaves as electricity, about 1,350 kW can be recovered as heat and about 450 kW is lost. The cleaning train uses little power but a lot of attention: the media in the hydrogen sulphide vessels is the part that is changed most often. The drawing does not show the engine cooling water circuit, the gas analyser, the water seal, the flame arresters, the air supply of the engine, the circuit breaker, or the control room.

Assumed inputs, not data from a particular plant. Gas composition, hydrogen sulphide, engine efficiency and heat recovery depend on the source, the engine and the design.

Safety: methane burns and can explode when it is mixed with air (typically between about 5 and 15 percent methane in air), and biogas also holds hydrogen sulphide, which is toxic, can be deadly at low concentrations and soon dulls the sense of smell. Carbon dioxide can collect in low places. Real plants rely on gas detection, ventilation, flame arresters, equipment made for hazardous areas, and permits to work. This lesson explains the principle and is education, not an operating procedure.

What the operator watches

  • Gas flow and methane share. A falling methane share or falling flow shows a problem at the digester or, at a landfill, too much suction pulling in air.
  • Hydrogen sulphide after the vessels. A rise means the lead vessel is almost used up and its media must be changed.
  • Condensate drains and gas temperature. A blocked drain lets water travel on to the engine.
  • Engine load, exhaust temperature and oil. They show how well the engine is running on the gas it is given.
  • Hot water temperatures. They show whether the heat reaches the digester and whether surplus heat must be dumped.

Common problems

  • Hydrogen sulphide breakthrough. Used-up media lets the gas through, and the engine oil turns acid and the engine wears fast.
  • Silicon compounds. Gas from landfills and from sewage digesters can carry siloxanes, which form hard glassy deposits in the engine. An activated carbon filter can remove them.
  • Wet gas. A failed chiller or a blocked drain sends water to the blower and engine.
  • Variable gas. A changing methane share makes the engine run roughly or trip.
  • Flare and engine trips. If the engine trips, the gas must go to the flare at once; a flare that fails to light leaves the digester or the wells under pressure.

Words you will meet

Biogas
A gas made when bacteria break down organic matter without oxygen, mostly methane and carbon dioxide.
Landfill gas
The same kind of gas, made slowly in buried waste.
Digester
A sealed, heated tank in which that breakdown is made to happen.
Condensate
The water that condenses out of the gas when it is cooled.
Hydrogen sulphide
A toxic gas with a smell of rotten eggs in the gas; it must be removed before the engine.
Lead and lag vessels
Two cleaning vessels in series: the first takes most of the load, and the order is swapped when its media is changed.
Gas blower
A low pressure fan that moves the gas and raises its pressure a little.
Flare
A stack that burns surplus gas safely.
Combined heat and power (CHP)
Making electricity and useful heat from the same fuel.
Synchronising
Matching the generator's voltage, frequency and phase to the network before connecting.

Check your understanding

Why is the gas cooled to about 5 °C before it goes to the engine?

Cooling makes the water vapour condense, so it can be drained away as liquid. Wet gas corrodes the pipes and, with hydrogen sulphide, makes acid. At 35 °C the gas holds about 40 g of water in each cubic metre, and at 5 °C only about 7 g, so about 33 g is removed from each cubic metre.

The engine uses the gas. Why is there a flare too?

The engine may be stopped for service or a fault, or the gas may be made faster than the engine can burn it. Burning the surplus in a flare turns methane into carbon dioxide and water. Methane warms the climate many times more than the same amount of carbon dioxide (over a century typically quoted as about 25 to 30 times), so burning it is better than releasing it.

Why does a plant that makes electricity also recover heat?

A gas engine turns only about 40 percent of the fuel into electricity. In the worked example 3,000 kW of fuel gives 1,200 kW of electricity but also about 1,350 kW of heat that can be recovered. Using both raises the total from 40 to about 85 percent, and the digester needs some of the heat to stay warm.

Key facts

Gas
Biogas is typically 55 to 65 percent methane; landfill gas about 45 to 55 percent.
Energy
About 6 kWh per m³ of biogas at 60 percent methane.
Cleaning
Cool to about 5 °C to drop the water; take out hydrogen sulphide.
Engine
Typically 35 to 42 percent electrical, 80 to 90 percent with heat recovered.
Frequency
Poles × rev/min ÷ 120: 4 × 1,500 ÷ 120 = 50 Hz.
Use the animation
Follow the olive green biogas from the digester (cut open, with its heating coil) and the landfill wells to the gas chiller (blue tubes, a condensate pot below), the two hydrogen sulphide vessels (brown beds), the blower and the engine container, which is cut open. A branch near the blower leads to the flare, where the flame comes and goes. Yellow lines carry power through the transformer to the pole. Grey exhaust gas goes to the heat exchanger, and the orange hot water loop runs back to the digester coil. Click the digester or the flare to open their lessons. The numbers on the drawing match the numbered steps under How it works. Hover over any part for its name and what it does.