Sacrificial anodes or a rectifier and ground bed push current into a buried pipe.
A buried steel pipeline is wet, salty ground on the outside and a flowing product on the inside. Steel in damp soil slowly turns back into rust. Cathodic protection stops this by using a small direct current. The current is arranged so that it runs into the pipe from the soil, and never out of it. Steel that receives current does not corrode.
Protection works together with a coating on the pipe. The coating does most of the work and the current protects the small places where the coating fails. This lesson is the overview of pipeline integrity. The gas pipeline pigging lesson shows how the inside of the pipe is cleaned and checked, and the crude pipeline station lesson shows the pumps that move the oil. The drawing shows two ways of making the current side by side. A real length of pipe usually has one system or the other.
Typical features: unprotected steel in soil sits at about −0.5 to −0.6 V against a copper sulphate electrode, and protection moves it more negative, to about −0.85 V or beyond. Too much is harmful too, because a potential much more negative than about −1.2 V can lift the coating. A coated pipe typically needs a few to some tens of microamperes for each square metre of surface, while bare steel in soil typically needs milliamperes, about a thousand times more. Magnesium anodes sit at about −1.5 V and zinc at about −1.1 V against the same electrode. Magnesium typically gives about 1,100 ampere-hours for each kilogram used, and zinc about 780.
Worked example 1, a sacrificial system. Assume a coated pipe 0.3 m across and 2 km long that needs 20 µA for each square metre, a life of 25 years, and anodes that each put out 15 mA.
| Quantity | Working | Result |
|---|---|---|
| Pipe surface | π × 0.3 × 2,000 | about 1,885 m² |
| Current needed | 1,885 × 20 µA | 37,700 µA, about 37.7 mA |
| Number of anodes | 37.7 ÷ 15 | 2.5, so 3 anodes |
| Charge over 25 years | 0.0377 A × 8,760 h × 25 | about 8,256 A·h |
| Magnesium needed | 8,256 ÷ 1,100 | about 7.5 kg, so three 5 kg anodes (15 kg) give about twice the minimum |
Worked example 2, an impressed current system. Assume a coated pipe 0.5 m across and 20 km long, the same 20 µA for each square metre, twice the current to allow for the coating ageing, and a circuit resistance of 5 Ω (ground bed, cables and soil).
| Quantity | Working | Result |
|---|---|---|
| Pipe surface | π × 0.5 × 20,000 | about 31,400 m² |
| Current needed | 31,416 × 20 µA | about 0.63 A |
| Design current, with an allowance of 2 | 0.63 × 2 | about 1.26 A |
| Voltage the unit must give | 1.26 A × 5 Ω | about 6.3 V |
| Power | 6.3 V × 1.26 A | about 7.9 W |
| The same pipe if it were bare, at 20 mA for each m² | 31,416 × 0.020 A | about 628 A, 1,000 times more |
The result shows why the coating matters. A real unit is rated much higher than this first figure, because the coating wears, the soil dries and the ground bed ages.
Assumed inputs, not data from a particular plant. Real designs depend on the coating, the soil resistivity, the pipe and the standards that apply.
Safety: the rectifier is connected to the grid voltage, and the pipe, cables and anodes can carry direct current that can spark if a joint is opened. The line itself may hold flammable gas or oil. Work on these systems is done by trained people with permits and tested equipment. This lesson explains the idea and is not a procedure.
The current only has to protect the steel that the soil can reach. The coating hides almost all of the steel, so only the holidays take current. In the worked example the bare pipe would need about 1,000 times more.
The magnesium or zinc block. It dissolves into the soil as ions, and that is the corrosion that would otherwise happen to the pipe. When the block is used up, it must be replaced.
The negative terminal. The pipe must receive current from the soil, and the positive terminal sends current out through the anodes of the ground bed. The current returns along the negative cable.