What a coal-fired boiler does
A coal-fired boiler turns the energy in coal into high-pressure, hot steam for the turbine. This lesson shows the most common design in large power stations: the pulverised-coal drum boiler. The coal is ground to a fine powder and blown into a tall furnace, where it burns in a flame. The furnace walls are made of water-filled tubes that take the heat. The steam is then dried, superheated and, in many plants, reheated. The heat that is left in the gas warms the feed water and the air before the gas goes up the stack.
Other boilers do the same job in other ways. The once-through boiler has no drum and is used at very high pressure. The circulating fluidised bed boiler burns crushed coal in a bed of hot particles. The stoker boiler burns lumps of coal on a moving grate. Parts of this boiler have their own lessons: the pulverising coal mill, the boiler drum and circulation, the burner firing arrangements and steam temperature control. The boiler is one part of the whole plant, shown in Coal plant: simple cycle.
How it works
Follow the path of the heat: from the coal and the air, through the flame, into the water and steam, and then out with the gas. The animation uses a colour for each stream, and the key is in the top left corner.
- 1Coal and air in. Raw coal from the coal handling system is fed to the mill, ground to powder and dried by hot primary air. The primary air carries the powder through pipes to the burners on the front wall. The windbox around the burners adds the secondary air, which supplies the rest of the air the flame needs.
- 2Furnace and flame. The powder burns in a fireball in the middle of the furnace. The walls are water-filled tubes that take the heat, mostly by radiation, and part of the water in them turns to steam. The coarse ash falls into the hopper at the bottom. The fine fly ash is carried up with the gas.
- 3Drum and circulation. The water and steam bubbles rise in the wall tubes (the risers) to the steam drum, where the steam is separated from the water. The water flows back down the downcomers, which are outside the heat, to the bottom of the furnace. The mixture in the heated tubes is lighter than the water in the downcomers, so the water circulates by itself. The water that tops up the drum comes from the economiser (step 6).
- 4Superheater. Saturated steam from the drum passes through the platen superheater in the top of the furnace and then the pendant superheater in the horizontal gas pass. A fine water spray between the sections, the attemperator, trims the steam temperature. The steam leaves the boiler at a temperature well above its boiling point and goes to the turbine.
- 5Reheater. In a reheat plant, the steam that has given up part of its energy in the high-pressure turbine (cold reheat steam) returns to the reheater in the back pass. It is heated again to nearly its first temperature (hot reheat steam) and goes to the next turbine section.
- 6Economiser and air heater. The feed water from the deaerator and the feed pump is warmed in the economiser by the cooler gas and then goes to the drum. Below it, in the tubular air heater, the gas flows down inside the tubes and the air flows across them, so the air is warmed. This hot air is the source of the primary and the secondary air.
- 7Gas cleaning and stack. The flue gas passes the electrostatic precipitator, which collects the fly ash on plates. The induced draft fan then pulls the gas through the boiler and pushes it up the stack. The induced draft fan and the forced draft fan together keep the furnace pressure a little below the outside air, so that flame and gas do not leak out (a balanced draught).
The numbers
Typical figures for a large subcritical drum boiler (they depend on the plant, the coal and the design):
| Item | Typical value |
|---|
| Main steam | about 16 to 17 MPa and about 540 °C |
| Hot reheat steam | about 540 °C, at a pressure of about 3 to 4 MPa |
| Flame temperature | above 1,500 °C |
| Gas leaving the furnace | roughly 1,000 to 1,200 °C |
| Gas leaving the air heater | roughly 120 to 150 °C |
| Excess air | roughly 15 to 25 percent (3 to 4 percent oxygen in the flue gas) |
| Primary air | roughly a fifth of the combustion air |
| Boiler efficiency | roughly 85 to 90 percent |
The coal needs a certain amount of air to burn completely (the theoretical air). A little more is supplied (the excess air), because the coal and the air never mix perfectly.
Worked example. Assumed inputs: main steam 400 kg/s at an enthalpy of 3,400 kJ/kg; feed water entering at 1,150 kJ/kg; reheat steam 330 kg/s heated from 3,030 to 3,540 kJ/kg; boiler efficiency 88 percent; coal with a heating value of 24 MJ/kg; theoretical air 8.5 kg per kg of coal; excess air 20 percent; coal ash 15 percent, of which 80 percent leaves as fly ash.
| Quantity | Working | Result |
|---|
| Heat to the main steam | 400 × (3,400 − 1,150) | 900,000 kW = 900 MW |
| Heat to the reheat steam | 330 × (3,540 − 3,030) | 168,300 kW, about 168 MW |
| Total heat to the steam | 900 + 168.3 | 1,068.3 MW |
| Fuel energy burned | 1,068.3 ÷ 0.88 | about 1,214 MW |
| Heat not given to the steam (mostly in the stack gas) | 1,214 − 1,068 | about 146 MW |
| Coal burned | 1,214 ÷ 24 | about 50.6 kg/s, which is 182 t/h |
| Combustion air | 50.6 × 8.5 × 1.20 (50.6 × 10.2) | about 516 kg/s |
| Ash | 50.6 × 0.15 | about 7.6 kg/s (27 t/h); fly ash 80 percent is about 6.1 kg/s (22 t/h) |
| Flue gas (air plus coal, less the ash) | 516 + 50.6 − 7.6 | about 559 kg/s |
| Primary air at one fifth of the air | 0.20 × 516 | about 103 kg/s, about 2 kg of air per kg of coal |
Assumed inputs, not data from a particular plant. The enthalpies are rounded values for steam of about this kind. The air per kg of coal depends on the coal.
Safety: unburned coal dust or fuel that collects in a furnace can explode, so boilers are purged and protected by flame supervision and trips. The surfaces are very hot and the steam is at high pressure. This lesson is education, not an operating procedure. Real work on a boiler follows the written procedures and permits of the plant.
What the operator watches
- Steam pressure and temperature. They are held by the fuel firing rate and, for temperature, by the attemperator sprays. The reheat temperature is watched too.
- Drum level and feed water flow. The level must stay in a narrow band. Too low can leave tubes without cooling, and too high can carry water into the superheater.
- Furnace pressure and oxygen. The furnace pressure is held a little below the outside air. The oxygen in the flue gas shows how much excess air there is.
- Flame and gas temperatures. A flame that is not stable is a danger. Gas temperatures that rise along the gas path warn of dirty tubes.
Common problems
- Slagging and fouling. Ash that melts and sticks to the walls and the superheater (slag) or builds up on the tubes in the back pass (fouling) cuts the heat transfer and raises the gas temperature.
- Tube leaks. Ash erosion, corrosion and overheating can open a hole in a tube. The leaking water can damage the tubes beside it, and the unit has to stop for the repair.
- Air heater trouble. If the gas gets too cold at the cold end, acid can condense and corrode the tubes, and ash can block them.
- Furnace explosion. A mixture of unburned fuel and air that gathers in the furnace and then ignites can damage the boiler. This is why the purge and the flame supervision matter.
Words you will meet
- Water wall
- The furnace wall made of water-filled tubes.
- Steam drum
- The vessel at the top where steam is separated from the water.
- Downcomer and riser
- The pipe that carries water down, and the heated tube that carries the water and steam mixture up.
- Superheater
- Tubes that heat the steam above its boiling temperature.
- Reheater
- Tubes that heat the steam again after it has passed the first turbine.
- Economiser
- Tubes that warm the feed water with the flue gas.
- Primary and secondary air
- Primary air carries the coal powder to the burners. Secondary air is added around the burner for the rest of the burning.
- Balanced draught
- A furnace pressure kept just below the outside air by the two fans.
Check your understanding
Why does the water circulate in a drum boiler without a pump?
The wall tubes are heated and hold a mixture of water and steam, which is light. The downcomers are outside the heat and hold only water, which is heavy. The heavy column pushes the light column up. The difference gets smaller as the pressure rises, so this works only below the critical pressure of water.
Why do the economiser and the air heater come last in the gas path?
Heat only flows from hot to cold. The hottest gas must meet the hottest surfaces, which are the superheater and the reheater. The cooler gas that is left can still warm the feed water and the air, and this takes heat out of the gas before it goes up the stack. A rough rule is that 20 °C less in the stack gas raises the boiler efficiency by about one percentage point.
In the example, what happens if the excess air is raised from 20 to 30 percent?
The air becomes 50.6 × 8.5 × 1.30 = about 559 kg/s, which is about 43 kg/s (about 8 percent) more. The extra air is heated and carries its heat up the stack, and the fans use more power.