What coal seam gas to LNG does
Coal seam gas (CSG) is methane held on the surface of coal by the pressure of the water in the seam. To get it out, the water is pumped away, the pressure falls, and the gas lets go of the coal and flows to the well. The gas is gathered, compressed, dried, sent along a pipeline to the coast, cooled to a liquid and shipped as liquefied natural gas (LNG). The water that comes up with it is treated.
This lesson follows the whole chain. Every major unit has a lesson of its own, linked in the steps below. In the animation you can click a unit to open its lesson.
How it works
- 1Pump the water out. A progressing cavity pump near the bottom of each well lifts water up the tubing. The water level falls, the pressure on the coal falls, and methane leaves the coal. It rises up the space between the tubing and the casing.
- 2Gather. At each well the gas and the water leave by separate outlets. Gas goes into low-pressure gathering lines. Water goes into its own line, to the water treatment plant. See wellhead separation and gathering.
- 3Compress. The gas is at low pressure. A field compression station takes out any liquid in a scrubber, compresses the gas and cools it, so that it can reach the central plant.
- 4Dry and treat. At the central gas plant the wet gas rises up a contactor against glycol, which takes the water out (gas dehydration). A regenerator heats the used glycol so it can be used again. The dry gas enters the high-pressure pipeline.
- 5Pipeline to the coast. A buried steel trunk pipeline, often hundreds of kilometres long, carries the gas to the LNG plant. The drawing shows a short length and leaves the middle out.
- 6Liquefy, store and ship. At the LNG plant the gas is treated again to take out water and acid gas, which would freeze. A cold box, cooled by compressors on a refrigerant loop, cools the gas to about −162 °C, and it becomes a liquid (LNG Liquefaction). The LNG is stored in insulated tanks and loaded onto a ship at a jetty (LNG Storage and Ship Loading).
- 7Treat the water. The water from the wells is salty. Most of it is treated by reverse osmosis: a high-pressure pump pushes it through membranes that hold the salt back. The clean water, the permeate, goes to a dam to be used. The salty brine goes to a lined pond.
The numbers
Typical features: wells are usually a few hundred metres deep, and in places down to about 1,000 m. Water comes first and gas follows. A young well makes more water than gas, and the water falls off as the well ages. A well can keep producing for many years. Keeping the water level down is what keeps the gas coming, so wells are kept pumping.
LNG is at about −162 °C at about atmospheric pressure, and takes up about 1/600 of the volume of the gas. The gas used up in the plant (fuel and liquefaction) is a share of the total, assumed here as 8 percent.
Worked example. Assume one LNG train of 4.5 million tonnes a year, 55 GJ of gas energy per tonne of LNG, 8 percent of the gas burned for fuel and liquefaction, a gas heating value of 38 MJ/m³ and an average well of 0.35 TJ/day.
| Quantity | Working | Result |
|---|
| Gas energy in the LNG | 4.5 million t × 55 GJ/t | 247.5 PJ/year |
| Gas needed, with the fuel share | 247.5 ÷ 0.92 | about 269 PJ/year |
| Per day | 269,000 TJ ÷ 365 | about 737 TJ/day |
| Wells needed | 737 ÷ 0.35 | about 2,100 wells |
| Gas volume per day | 737,000 GJ ÷ 0.038 GJ/m³ | about 19.4 million m³/day |
Assumed inputs, not data from a particular plant. A real field adds wells all the time because the gas rate of each well falls, so the drilling never stops. Well rates, plant sizes and pipeline lengths differ from one project to the next.
Safety: the gas is methane, which burns and can explode when it mixes with air. LNG is extremely cold and can burn skin on contact, and a pipeline carries gas at high pressure. This lesson explains the idea and is not a procedure.
What the operator watches
- The wells. Pump speed and water level at each well, and the gas and water rates at each separator.
- The compressors. Suction pressure and discharge temperature at the field compression stations.
- The pipeline. Pressure and flow along the trunk pipeline, and the quality of the gas that reaches the plant.
- The water plant. The pressure drop across the reverse osmosis membranes, which shows when they are fouling.
Common problems
- Fines and gas at the well. Coal fines and sand block or wear the pump, and gas drawn into the pump upsets it.
- Falling suction pressure. As wells age, the gas pressure at a compressor inlet falls and the compressor can trip on low suction pressure.
- Dehydration fails. Water left in the gas can form hydrate (an ice-like solid) or corrode the pipeline, and it freezes in the LNG plant.
- Membrane fouling. Scale and fine solids build up on the reverse osmosis membranes and the pressure drop rises.
Words you will meet
- Desorption
- Gas leaving the surface of the coal when the pressure on it falls.
- Gathering line
- A low-pressure pipe that collects the gas (or the water) from many wells.
- Dehydration
- Taking the water out of the gas, here with glycol.
- Trunk pipeline
- The long, high-pressure pipeline that carries the gas to the coast.
- Produced water
- The salty water that comes up from the wells with the gas.
- Reverse osmosis
- Pushing water through membranes at high pressure so that the salt stays behind.
- Brine
- The salty water left behind when the clean water has passed through the membranes.
- LNG train
- One complete line of equipment that turns gas into LNG.
Check your understanding
Why does pumping water out of a coal seam produce gas?
The pressure of the water holds the methane on the coal. Pumping water out lowers that pressure, so the gas leaves the coal and flows to the well.
Why is the gas dried before it goes into the pipeline?
Water in the gas can form hydrate, an ice-like solid, and can corrode the pipe. It would also freeze later, when the gas is cooled to make LNG.
Why does the field keep drilling new wells?
The gas rate of each well falls as it ages. To supply the same plant year after year, new wells have to replace the lost gas.