Raw gas to sales gas: separation, sweetening, drying, NGL recovery and compression.
Gas from a well is not yet gas that can be sold. It carries liquid water and light oil, it is wet with water vapour, it may hold carbon dioxide and toxic hydrogen sulphide, and it holds ethane, propane and butanes that are worth more as liquids. A gas processing plant cleans the gas in steps until it meets the specification of the sales pipeline. It also collects the liquids it takes out as products.
The steps are separation, sweetening, dehydration, NGL recovery and compression. Each has its own lesson: amine treating, glycol dehydration and molecular sieve dehydration, NGL recovery and the gas compressor. The gas arrives from a field gathering system, for example the field compression station of a coal seam gas field, and leaves by a trunk pipeline (see pipeline pigging). On the drawing, click a unit with its own lesson to open it.
Typical features: raw gas with typically 0 to 10 percent of acid gases, depending on the field; a sales gas water content of typically under 100 mg for each m³ for a pipeline, and under about 1 mg for each m³ ahead of a cold plant; an NGL content of the gas of typically 3 to 15 percent by volume for a rich gas; and a volume loss to NGL, the shrinkage, of typically 5 to 15 percent of the gas.
Worked example, one plant balance. Assume 12 million m³ a day of raw gas (measured at standard conditions, 23.64 m³ for each kmol) with 4% carbon dioxide and 0.1% hydrogen sulphide. After sweetening the dry gas has, by mole, methane 87%, ethane 7%, propane 3.5%, butanes and heavier 1.5% and nitrogen 1%. Assume 600 mg of water in each m³ of sweet gas, recoveries of 85% for ethane, 98% for propane and 100% for butanes and heavier, and a residue gas compressed from 2,500 to 8,000 kPa at an inlet temperature of 40°C, an efficiency of 78%, a specific heat ratio of 1.3 and an ideal gas.
| Quantity | Working | Result |
|---|---|---|
| Acid gas taken out by the amine | 12,000,000 × 0.041 | 492,000 m³/d |
| Sweet gas | 12,000,000 − 492,000 | 11,508,000 m³/d |
| Water taken out by the dryers | 11,508,000 × 0.0006 kg | about 6,900 kg/d |
| Ethane recovered | 11,508,000 × 0.07 × 0.85 | 684,700 m³/d, 871 t/d at 30.07 kg/kmol |
| Propane recovered | 11,508,000 × 0.035 × 0.98 | 394,700 m³/d, 736 t/d at 44.10 kg/kmol |
| Butanes and heavier recovered | 11,508,000 × 0.015 | 172,600 m³/d, 424 t/d at 58.12 kg/kmol |
| NGL product | 871 + 736 + 424 | 2,031 t/d, about 2,000 t/d |
| Residue gas | 11,508,000 − (684,700 + 394,700 + 172,600) | 10,256,000 m³/d |
| Shrinkage | 1,252,000 ÷ 11,508,000 | 10.9%, about 11% |
| Residue gas mass (average 16.4 kg/kmol) | 10,256,000 ÷ 23.64 × 16.4 ÷ 86,400 | 82 kg/s |
| Compressor head, ideal gas (R = 0.508 kJ/kg K) | 4.33 × 0.508 × 313 × (3.20.231 − 1) | 212 kJ/kg |
| Compressor shaft power | 82 × 212 ÷ 0.78 | about 22,000 kW, 22 MW |
The 22 MW is the largest single power use in the plant. A real compressor does the job in two or more stages with a cooler between them, which lowers the power somewhat, and the expander compressor in the NGL section does part of the work.
Assumed inputs, not data from a particular plant. Gas composition, recoveries, pressures and specifications change with the field, the products and the sales contract.
Safety: the gas is flammable and at high pressure. The raw gas can hold hydrogen sulphide, which is toxic at very low levels and dulls the sense of smell. Parts of the NGL section are at about minus 100°C, and the NGL itself is a flammable liquid that boils off easily. The design relies on gas detection, relief valves to a flare, emergency shutdown systems, spacing between the units and permits to work. This lesson explains the principle and is not an operating procedure.
The amine unit leaves the gas wet, because the gas picks up water from the amine solution. So the dryers must come after it. Taking the acid gases out first also protects the dryers and the cold section from them.
The gas is cooled to about minus 100°C there. Any water would freeze and block the cold box. A pipeline only needs the water to be low enough that no liquid water forms at the pipeline temperatures.
The volume leaves the gas, but it leaves as NGL liquids that are sold at a higher value per unit of energy. In the example 2,000 t a day of NGL replaces about 1.25 million m³ of gas.