Gas Processing Plant (overview)

Raw gas to sales gas: separation, sweetening, drying, NGL recovery and compression.

Loading the animation…
You are watching a free lesson. A free account saves your progress and lets you mark lessons complete. Create a free account Sign in

What a gas processing plant does

Gas from a well is not yet gas that can be sold. It carries liquid water and light oil, it is wet with water vapour, it may hold carbon dioxide and toxic hydrogen sulphide, and it holds ethane, propane and butanes that are worth more as liquids. A gas processing plant cleans the gas in steps until it meets the specification of the sales pipeline. It also collects the liquids it takes out as products.

The steps are separation, sweetening, dehydration, NGL recovery and compression. Each has its own lesson: amine treating, glycol dehydration and molecular sieve dehydration, NGL recovery and the gas compressor. The gas arrives from a field gathering system, for example the field compression station of a coal seam gas field, and leaves by a trunk pipeline (see pipeline pigging). On the drawing, click a unit with its own lesson to open it.

How it works

  1. Inlet separation. The raw gas arrives at typically 4,000 to 8,000 kPa. A slug catcher takes the slugs of liquid that arrive with it, and the inlet separator lets the gas rise out of the liquid, as in the three-phase separator. The condensate floats on the water and each is drawn off by itself. The condensate goes on to stabilisation, and the water to treatment.
  2. Sweetening. The gas goes up an amine absorber, against amine running down. The amine takes out the carbon dioxide and the hydrogen sulphide, the acid gases. The gas that leaves the top is sweet. A pipeline allows typically only a few parts per million of hydrogen sulphide and a few percent of carbon dioxide, and a cold plant allows much less carbon dioxide. The amine is regenerated by heat in a second column that is not drawn, and the acid gas goes to sulphur recovery (see Claus sulphur recovery).
  3. Dehydration. The sweet gas is still saturated with water vapour. If the gas goes straight into a pipeline, a glycol unit dries it enough. If the gas is going to be cooled far below zero, as in the NGL section, two vessels of molecular sieve dry it much further. One is on duty while the other is regenerated with hot gas.
  4. NGL recovery. In the cold box the dry gas is cooled by the cold residue gas. A turbo-expander lets the gas down in pressure and makes it very cold, so that ethane, propane and the heavier parts condense. The demethaniser separates the liquid from the methane. The methane leaves from the top as residue gas. The ethane, propane and heavier parts leave from the bottom as NGL.
  5. Compression to the pipeline. The residue gas is at the low pressure of the demethaniser. A compressor, driven by an electric motor or a gas engine or turbine, takes it up to the pressure of the sales pipeline, typically 7,000 to 10,000 kPa. The gas passes a metering station on its way into the pipeline.
  6. NGL and condensate. The NGL is pumped to pressure vessels, drawn as bullet tanks, until it is sent away. It can go as one mixed stream or be split in a fractionation train into ethane, propane, butanes and a gasoline. The condensate from the inlet separator is stabilised first, so that its vapour pressure is safe to store and carry.

The numbers

Typical features: raw gas with typically 0 to 10 percent of acid gases, depending on the field; a sales gas water content of typically under 100 mg for each m³ for a pipeline, and under about 1 mg for each m³ ahead of a cold plant; an NGL content of the gas of typically 3 to 15 percent by volume for a rich gas; and a volume loss to NGL, the shrinkage, of typically 5 to 15 percent of the gas.

Worked example, one plant balance. Assume 12 million m³ a day of raw gas (measured at standard conditions, 23.64 m³ for each kmol) with 4% carbon dioxide and 0.1% hydrogen sulphide. After sweetening the dry gas has, by mole, methane 87%, ethane 7%, propane 3.5%, butanes and heavier 1.5% and nitrogen 1%. Assume 600 mg of water in each m³ of sweet gas, recoveries of 85% for ethane, 98% for propane and 100% for butanes and heavier, and a residue gas compressed from 2,500 to 8,000 kPa at an inlet temperature of 40°C, an efficiency of 78%, a specific heat ratio of 1.3 and an ideal gas.

QuantityWorkingResult
Acid gas taken out by the amine12,000,000 × 0.041492,000 m³/d
Sweet gas12,000,000 − 492,00011,508,000 m³/d
Water taken out by the dryers11,508,000 × 0.0006 kgabout 6,900 kg/d
Ethane recovered11,508,000 × 0.07 × 0.85684,700 m³/d, 871 t/d at 30.07 kg/kmol
Propane recovered11,508,000 × 0.035 × 0.98394,700 m³/d, 736 t/d at 44.10 kg/kmol
Butanes and heavier recovered11,508,000 × 0.015172,600 m³/d, 424 t/d at 58.12 kg/kmol
NGL product871 + 736 + 4242,031 t/d, about 2,000 t/d
Residue gas11,508,000 − (684,700 + 394,700 + 172,600)10,256,000 m³/d
Shrinkage1,252,000 ÷ 11,508,00010.9%, about 11%
Residue gas mass (average 16.4 kg/kmol)10,256,000 ÷ 23.64 × 16.4 ÷ 86,40082 kg/s
Compressor head, ideal gas (R = 0.508 kJ/kg K)4.33 × 0.508 × 313 × (3.20.231 − 1)212 kJ/kg
Compressor shaft power82 × 212 ÷ 0.78about 22,000 kW, 22 MW

The 22 MW is the largest single power use in the plant. A real compressor does the job in two or more stages with a cooler between them, which lowers the power somewhat, and the expander compressor in the NGL section does part of the work.

Assumed inputs, not data from a particular plant. Gas composition, recoveries, pressures and specifications change with the field, the products and the sales contract.

Safety: the gas is flammable and at high pressure. The raw gas can hold hydrogen sulphide, which is toxic at very low levels and dulls the sense of smell. Parts of the NGL section are at about minus 100°C, and the NGL itself is a flammable liquid that boils off easily. The design relies on gas detection, relief valves to a flare, emergency shutdown systems, spacing between the units and permits to work. This lesson explains the principle and is not an operating procedure.

What the operator watches

  • Sales gas quality. Heating value, water content, hydrogen sulphide and carbon dioxide are checked all the time, because gas that is off specification cannot go into the pipeline.
  • Inlet flow, pressure and liquid levels. A slug of liquid shows first at the inlet separator, and the plant downstream must see a steady flow.
  • The dryer cycle and the cold section. The moisture at the sieve outlet, and the temperatures at the cold separator, the expander outlet and the top of the demethaniser.
  • Compressors and storage. Compressor vibration, temperatures and surge margin, and the pressure and level in the NGL tanks.

Common problems

  • Slugging. A large slug of liquid from the field fills the inlet vessels, and liquid carries over into the amine unit.
  • Foaming in the amine. Liquid hydrocarbons or dirt make the amine foam, and the gas carries amine on to the dryers.
  • Freezing in the cold section. Water or carbon dioxide that gets past the dryers and the amine freezes in the cold box.
  • Upsets that send gas to the flare. A trip of a compressor or a pipeline that cannot take the gas raises the pressure in the plant, and relief valves send the excess to the flare.

Words you will meet

Raw gas
Gas as it arrives from the wells, before any treatment.
Sour and sweet gas
Sour gas holds hydrogen sulphide. Sweet gas has had it taken out.
Acid gas
Hydrogen sulphide and carbon dioxide, taken out in the amine unit.
Condensate
Light liquid oil that drops out of the gas when it is separated.
NGL
Natural gas liquids: ethane, propane, butanes and heavier parts.
Residue gas
The gas that is left after the NGL is out. It is mostly methane.
Sales gas
Gas that meets the specification and goes into the pipeline.
Shrinkage
The volume of gas lost, in percent, because the NGL is taken out as liquid.

Check your understanding

Why does the plant take the carbon dioxide and hydrogen sulphide out before it dries the gas?

The amine unit leaves the gas wet, because the gas picks up water from the amine solution. So the dryers must come after it. Taking the acid gases out first also protects the dryers and the cold section from them.

Why does the NGL section need much drier gas than the pipeline does?

The gas is cooled to about minus 100°C there. Any water would freeze and block the cold box. A pipeline only needs the water to be low enough that no liquid water forms at the pipeline temperatures.

Why is the shrinkage not a loss to the owner?

The volume leaves the gas, but it leaves as NGL liquids that are sold at a higher value per unit of energy. In the example 2,000 t a day of NGL replaces about 1.25 million m³ of gas.

Key facts

Purpose
Turn raw gas into sales gas and recover the liquids.
Order of steps
Separation, sweetening, dehydration, NGL recovery, compression.
Products
Sales gas, NGL and condensate, with sulphur from the acid gas.
Sales pressure
Typically 7,000 to 10,000 kPa.
Shrinkage
Typically 5 to 15 percent of the gas.
Use the animation
Follow the gas from the raw gas inlet on the left through the slug catcher and the inlet separator, then up the amine absorber, where the purple amine takes the acid gases out. The sweet gas crosses to two sieve vessels, one on duty and one regenerating. The dry gas goes behind the vessels to the cold box. Watch the cold gas go to the turbo-expander and the demethaniser, the NGL to the bullet tanks, and the cold residue gas back through the cold box and on to the compressor and the sales gas line. Click a unit that has its own lesson to open it. The numbers on the drawing match the numbered steps under How it works. Hover over any part for its name and what it does.