What a hydrogen electrolysis plant does
A hydrogen electrolysis plant turns water and electricity into hydrogen gas. The heart of it is the electrolyser, where direct current splits water into hydrogen and oxygen. Everything else in the plant is there to feed the electrolyser clean water and power, or to take its gas and make it ready to use: separate it from water, clean it, dry it, compress it and store it.
If the electricity comes from wind or solar power, the hydrogen is called green hydrogen, and the plant turns electricity that is hard to store into a gas that can be stored. The plant is made of equipment that has its own lessons, and you can click each one in the animation: the water treatment, the electrolyser, the compressor (a piston machine, as in the field compression station) and the hydrogen storage. The drawing cuts the electrolyser hall open and shows three stacks inside.
How it works
Follow the water through the plant from left to right, and then the hydrogen to the storage tubes. The oxygen leaves at the separator.
- 1Water treatment. Raw water from the mains or a bore is filtered and passed through membranes (reverse osmosis) and a polishing step that take out the dissolved salts. The result is demineralised water, with a conductivity typically below about 1 microsiemens per centimetre, held in a tank. A pump sends it to the electrolyser. The electrolyser needs about 9 kg of water for each kilogram of hydrogen, and a plant typically takes about 10 to 15 litres of raw water for each kilogram because some is lost in the treatment.
- 2Power supply. A transformer lowers the grid voltage and a rectifier turns the alternating current into the direct current the stacks need. The rectifier sets how much current flows, so it sets how much hydrogen is made. A good rectifier loses only a few percent of the power as heat.
- 3Electrolyser. In the hall the stacks split the water: oxygen forms at one electrode and hydrogen at the other, and a membrane or separator keeps them apart. Each stack is a pile of cells in series (see the electrolyser lesson). The two gases leave through separate pipes, still carrying some water. A typical electrolyser delivers hydrogen at about 1 to 30 bar, depending on the type.
- 4Gas separators. In the oxygen separator and the hydrogen separator each gas rises out of the water that carried it. The water goes back to the stacks. Oxygen is usually released to the air, or sold if there is a use for it. The hydrogen leaves wet and with a trace of oxygen in it.
- 5Purification and drying. A small deoxo vessel with a catalyst combines the trace of oxygen with some hydrogen to make water. Then twin dryer towers hold beds of adsorbent that take out the last water. One tower dries the gas while the other is heated and flushed to dry its bed, and then they swap. The hydrogen leaves typically 99.9 to 99.999 percent pure, depending on what it is for.
- 6Compression. A multi-stage piston compressor raises the pressure from the electrolyser pressure to the storage or delivery pressure, typically 200 to 500 bar. Each stage raises the pressure by a ratio of about 2 to 4, and the gas is cooled between the stages, because compression heats it.
- 7Storage and delivery. The compressed hydrogen goes into a bank of storage tubes that works as a buffer between the electrolyser, whose output follows the power, and the users, whose demand follows their own needs. From there the gas goes through a regulator to a pipeline, a filling point for tube trailers or a process (see hydrogen storage).
The numbers
Typical features: a complete plant uses about 50 to 55 kWh of electricity for each kilogram of hydrogen. The lower heating value of hydrogen is 33.3 kWh/kg, so about 60 to 67 percent of the energy comes out as hydrogen, and the rest is heat. Each kilogram of hydrogen needs about 9 kg of water and gives about 8 kg of oxygen. One kilogram of hydrogen is about 11.1 normal cubic metres of gas (a normal cubic metre is one at 0°C and normal atmospheric pressure). Plants range from a fraction of a megawatt to hundreds of megawatts.
Worked example, one plant. Assume 10 MW of electricity into the plant, 52 kWh for each kilogram of hydrogen for the whole plant, a reverse osmosis recovery of 70 percent, and compression from about 30 bar to 350 bar.
| Quantity | Working | Result |
|---|
| Hydrogen made | 10,000 kW ÷ 52 kWh/kg | about 192 kg/h |
| Hydrogen in a day | 192 × 24 | about 4,600 kg, 4.6 tonnes |
| Gas volume at normal conditions | 192 ÷ 0.0899 kg/m³ | about 2,140 normal m³/h |
| Oxygen made | 8 × 192 | about 1,540 kg/h, 1.5 tonnes an hour |
| Pure water used | 9 × 192 | about 1,730 kg/h, 1.7 m³/h |
| Raw water taken in | 1.73 ÷ 0.70 | about 2.5 m³/h, about 13 litres for each kilogram of hydrogen |
| Energy in the hydrogen (lower heating value) | 192 × 33.3 kWh/kg | about 6,400 kW, 6.4 MW |
| Plant efficiency (lower heating value) | 33.3 ÷ 52 | about 64 percent |
| Heat released | 10 − 6.4 MW | about 3.6 MW, mostly in the stack cooling water and the compressor coolers |
| Compression work if done at constant temperature, 30 to 350 bar, 300 K | 496 mol/kg × 8.314 × 300 × ln(350 ÷ 30) ÷ 3.6 million | about 0.84 kWh/kg |
| Real compressor, taken as 2 to 2.5 times that, say 2 kWh/kg | 2 × 192 | about 385 kW, about 4 percent of the plant power |
| Four hours of buffer storage | 192 × 4 | 768 kg (see the hydrogen storage lesson for the tubes) |
The numbers show where the electricity goes. The electrolyser stacks use most of it, with the pumps, cooling, drying and compression sharing the rest, so improving the cell voltage in the stacks does more than anything else. The drawing does not show the cooling circuits, the water return from the separators, the nitrogen used to purge the plant, or the control room.
Assumed inputs, not data from a particular plant. Energy use, pressures, purity and recovery depend on the type of electrolyser, the design and the load.
Safety: hydrogen is very flammable over a wide range of mixtures with air, ignites with very little energy and leaks easily, and its flame can be almost invisible in daylight. Oxygen makes materials burn much more fiercely, and the plant also has high direct current and high-pressure gas. Real plants rely on ventilation, gas detection, careful choice of materials, relief valves to a safe vent, separation distances and permits to work. This lesson explains the principle and is education, not an operating procedure.
What the operator watches
- Stack voltage and current. The current follows the power available, and a rising cell voltage at the same current shows ageing or dirty water.
- Water quality. The conductivity of the pure water going to the stacks, and the pressure drop across the filters and membranes of the water treatment.
- Gas purity and levels in the separators. The oxygen in the hydrogen and the hydrogen in the oxygen are kept well below the flammable limits, and the liquid levels keep each gas from passing into the wrong pipe.
- Dryer dew point and changeover, compressor pressures and temperatures, storage pressure. They show whether the gas is dry enough and whether the machines are healthy.
Common problems
- Poor water. Fouled membranes or exhausted polishing beds let salts through, and the stacks lose performance for good.
- Low-load operation. When the plant follows a changing power supply it can run at a low load, where the share of hydrogen in the oxygen rises, so there is a lowest allowed load.
- Wet hydrogen. A dryer bed that is saturated or badly regenerated lets water through, which corrodes tubes and spoils the gas for the users.
- Compressor wear and leaks. Valves and piston rings wear, and every joint in a hydrogen line is a place to look for leaks.
Words you will meet
- Electrolyser
- The unit that splits water into hydrogen and oxygen with electric current.
- Stack
- A pile of electrolyser cells in series.
- Rectifier
- A device that turns alternating current into direct current.
- Demineralised water
- Water with almost all of its dissolved salts removed.
- Separator
- A vessel where gas rises out of the water that carried it.
- Deoxo
- A catalyst vessel that removes the last oxygen from hydrogen by turning it into water.
- Adsorbent
- A solid that holds water on its surface, used in the dryer towers.
- Intercooler
- A cooler between two stages of a compressor.
- Balance of plant
- Everything in the plant other than the stacks: pumps, coolers, dryers, compressors and controls.
Check your understanding
The plant makes 8 kg of oxygen for each kilogram of hydrogen. Where does the oxygen come from?
From the water. A molecule of water has two hydrogen atoms and one oxygen atom. By mass, 18 g of water gives 2 g of hydrogen and 16 g of oxygen, which is 8 kg of oxygen for each kilogram of hydrogen.
Why is the hydrogen dried before it is compressed and stored?
Wet gas that is compressed and cooled drops water, which corrodes the tubes and can block valves. Many users, such as fuel cells, also need very dry hydrogen.
Why does the compressor have a cooler between its stages?
Squeezing a gas heats it. Cooling it between the stages keeps the temperatures within limits and makes the next stage need less work, because cool gas is easier to compress than hot gas.