Mine Dewatering

How a mine keeps water out: bores, sumps and staged pumping to a surface dam.

Loading the animation…
You are watching a free lesson. A free account saves your progress and lets you mark lessons complete. Create a free account Sign in

What mine dewatering does

A mine dewatering system keeps water out of the places where people and machines work. It lowers the water table around the mine, collects the water that still gets in, and pumps it to the surface, where it is reused or released.

Water is the constant companion of a mine. Groundwater seeps into an open pit and into underground workings, and rain falls into the pit. The mine has to move this water out every day, and almost always uphill, so dewatering is mostly a matter of sumps, pipes and pumps.

How it works

The animation shows an open pit and an underground decline side by side, with the ground cut open. The system has three parts: bores that lower the water table before the water reaches the workings, sumps that collect what still gets in, and pump stations that lift it out.

  1. 1Water arrives. Below the water table the rock is full of water. Groundwater seeps into the workings through cracks and permeable rock, and rain runs into the open pit.
  2. 2Bores draw down the water table. Dewatering bores are drilled around the mine. A submersible pump low in each bore pumps groundwater out ahead of mining. The water table dips toward each bore in a cone of depression, so the rock around the pit and the decline is drier.
  3. 3Water drains to a sump. The water that still gets in runs along drains to a low point, the sump. In the pit the sump is a pond on the floor, with a pump on a floating pontoon. Underground it is at a low point of the decline.
  4. 4Solids settle. The underground sump is built, as part of the underground pump station, so that mud and grit settle before the water reaches the pumps. A sump that is not cleaned out fills with sludge, and the solids wear the pumps.
  5. 5Pumps lift it. Multistage centrifugal pumps in the underground pump station lift the clear water. A deep mine is pumped in stages: each pump station lifts the water, typically a few hundred metres, to the next station.
  6. 6Rising main to surface. A steel pipe, the rising main, carries the water up the decline or a shaft. Non-return valves stop the column of water falling back when a pump stops.
  7. 7Reuse or release. On surface the water goes to a dam, and its inflows and outflows are kept in a mine water balance. From there it is used in the process plant and for dust suppression on the haul roads, or it is treated and released.

The numbers

Each metre of lift needs about 9.81 kPa of pressure, so 300 m of lift is about 29 bar. The velocity in a rising main is typically about 1 to 2 m/s. Pump power = density × gravity × flow × head ÷ efficiency.

Worked example. Assume an underground mine 600 m deep with a steady inflow of 40 L/s. The water is lifted in two stages of 300 m, the pumps are 70 percent efficient, and the rising main has an inside diameter of 200 mm.

QuantityWorkingResult
Flow40 L/s × 3,600 ÷ 1,0000.040 m³/s = 144 m³/h
Hydraulic power, total lift1,000 × 9.81 × 0.040 × 600 ÷ 1,000about 235 kW
Shaft power at 70 percent efficiency235 ÷ 0.70about 336 kW, plus pipe friction
Per stage (two equal stages)336 ÷ 2about 168 kW each
Pressure at the bottom of a 300 m stage300 × 9.81about 2,943 kPa = 29.4 bar
Rising main area, 200 mm3.1416 × 0.1 × 0.10.0314 m²
Velocity in the rising main0.040 ÷ 0.0314about 1.27 m/s
Water pumped per day144 × 243,456 m³ (about 3.5 ML)
Sump volume to hold 2 hours of inflow144 × 2288 m³

The inflow never stops, so the pumps run around the clock: in this example they lift about 3.5 million litres a day. Pumping in two stages halves the pressure that each pump, pipe and valve has to hold.

Assumed inputs, not data from a particular mine. A real design adds the friction loss in the pipe, spare pumps, and enough sump volume to ride out a power failure. Inflow, lift and the limits on released water are different at every site.

Safety: water in a mine is a serious hazard. A sudden inflow or a flooded sump can cut off the way out, and a pump station combines high pressure with high voltage. Mines plan for this with standby pumps, level alarms and escape routes. This lesson is education, not a procedure.

What the operator watches

  • Sump level. The level and how fast it rises show whether the pumps are keeping up with the inflow.
  • Pump current and discharge pressure. A change in either points to wear, a blockage or a pump that has lost its water.
  • Water levels in the bores. They show whether the water table is staying below the workings.
  • Sediment and water quality. The depth of sludge in the settling sump, and the quality of the water in the dam before it is reused or released.

Common problems

  • A sump full of sludge. The pumps starve, or they pump grit and wear out quickly.
  • An airlocked pump. A pump that has drawn in air stops moving water even though it is running.
  • Water hammer. A non-return valve that slams shut when a pump stops sends a pressure shock along the rising main.
  • Power loss. The inflow continues while the pumps are stopped, so the lowest workings flood first.

Words you will meet

Aquifer
Rock or soil that holds groundwater and lets it flow.
Water table
The level below which the ground is full of water.
Drawdown
The fall in the water table caused by pumping.
Cone of depression
The cone-shaped dip in the water table around a pumped bore.
Sump
A low point where water collects before it is pumped away.
Rising main
The pipe that carries pumped water up to the surface.
Multistage pump
A pump with several impellers in a row, each adding pressure, for a high lift.
Duty and standby
One pump runs (duty) and another is ready to take over (standby).

Check your understanding

Why is a deep mine pumped in stages?

The pressure rating of the pumps, pipes and valves limits the lift of one stage. Stages also mean that one failure does not stop all the pumping.

Why are the solids settled in a sump before the pumps?

Mud and grit wear and block the pumps. Clear water is much kinder to them.

What does a non-return valve in the rising main do?

It stops the column of water in the pipe draining back down when a pump stops.

Key facts

Three parts
Bores lower the water table, sumps collect what still gets in, pump stations lift it out.
Pressure of lift
About 9.81 kPa for each metre, so about 29 bar for 300 m.
Rising main velocity
Typically about 1 to 2 m/s.
Staged pumping
Deep mines lift the water from station to station, typically a few hundred metres at a time.
After pumping
The water goes to a dam, then to reuse or to treatment and release.
Use the animation
The animation is clickable: click a piece of equipment that has its own lesson to open it: the bores, the sumps and pump stations, the dam, the pumps, the valves and the treatment tank. Water is blue and it moves on every pipe. Look for the water table and how it dips toward each bore. Follow the seepage and the rain into the pit sump, and the drain water into the underground sump. Then follow the rising main up the decline, past the non-return valves, to the dam on surface. The numbers on the drawing match the numbered steps under How it works. Hover over any part for its name and what it does.