What mine ventilation does
A ventilation system moves fresh air from the surface down to the places where people and machines work, sweeps the used air out again, and keeps the air safe to breathe and cool enough to work in. Underground it is life support: it supplies oxygen, thins out diesel exhaust, blast fumes, dust and gas, and carries heat away.
The animation cuts a block of ground open. Fresh air is cooled by the air chiller at the intake shaft, goes down the shaft, crosses the working levels past a truck, a stope and a drill, and leaves through the return airway and the exhaust shaft, pulled by the main ventilation fan on the surface. It is the map of this track: the fan has its own lesson.
How it works
Air only moves if there is a pressure difference. Here the main fan sits at the top of the exhaust shaft and pulls, so the whole mine is under a slight suction and fresh air is drawn in at the other end. Fresh air is drawn as light cyan chevrons, used air as warmer, greyer chevrons, and the hot outside air before it is cooled as orange chevrons.
- 1Fresh air in. Air enters the mine through the intake shaft (in other mines, through the decline) and goes down to the working levels. No fan pushes it in: the main fan at the far end draws it down.
- 2Distribute. At each level the air divides into splits, one for each working area. Air always takes the easiest path, so it has to be steered. Air doors, regulators and stoppings are the ventilation controls. Air doors let people and vehicles pass but stop fresh air taking a short cut to the return. A regulator is an adjustable opening that sets how much air a split receives. A stopping is a wall that seals off a drive that is no longer used.
- 3Auxiliary fan and duct. A dead-end heading has no way through, so the main airflow passes its entrance and leaves it stagnant. An auxiliary fan (see auxiliary ventilation) hung in the fresh air, upstream of the entrance, forces air along a duct to the face where the drill works. The used air flows back along the heading.
- 4Dilute and carry away. The moving air thins out diesel exhaust from the truck, blast fumes (see blast design and firing), dust and any gas from the rock, and carries them away from the people. The air quantity for a working area is set mainly by the diesel engines running in it.
- 5Heat removal. The same air takes up heat from the rock, from the broken ore in the stope, from engines and from people, so it leaves the working places warmer than it arrived. In deep or hot mines the air alone is not enough and the mine adds cooling plant. The simplest first step is a surface air chiller, also called a bulk air cooler, at the top of the intake shaft: chilled water from a row of containerised chillers is sprayed into the incoming air, so it goes down the shaft cool (see the mine air chiller lesson). Cooling underground can add to it.
- 6Return air. Used air does not go back past the workers. It is collected in return airways, here the upper level and the rise that joins it to the lower level, and flows to the exhaust shaft.
- 7Main fan. A large fan at the top of the exhaust shaft draws the air through the whole mine and blows the used air out to the atmosphere. Its power rises roughly with the cube of the airflow, so a small cut in flow saves a lot of electricity.
The numbers
The basic relation is airflow = airway area × air speed, in m³/s. Typical features, all of them site dependent:
- Air for diesel engines. A typical rule of thumb is about 0.05 to 0.06 m³/s of air for each kilowatt of diesel engine power in the split. The required figure is set by the mine safety rules, and those differ from state to state and from country to country, so use the figure your regulator gives.
- Minimum air speed. Rules typically also ask for a minimum air speed where people work, of the order of a few tenths of a metre per second. The exact value depends on the state and on the type of mine.
- Heat. Mines typically start to restrict work when the wet bulb temperature reaches the high twenties in degrees Celsius. The limits again differ by state and by mine.
- Fan laws (same fan, same mine): pressure rises with the square of the airflow and power with the cube.
Worked example. Assume a main airway 5 m wide and 5 m high, four diesel trucks of 400 kW each working in the same split, an air allowance of 0.06 m³/s per kW (an assumed value, check the local rule) and an air density of 1.2 kg/m³.
| Quantity | Working | Result |
|---|
| Airway area | 5 × 5 | 25 m² |
| Diesel power in the split | 4 × 400 | 1,600 kW |
| Air needed for the diesel engines | 1,600 × 0.06 | 96 m³/s |
| Air speed in the airway | 96 ÷ 25 | about 3.8 m/s |
| Mass of that air | 96 × 1.2 = 115 kg/s; 115.2 × 3,600 ÷ 1,000 | about 415 t of air each hour |
| Fan pressure if the flow falls to 70 percent | 0.70 × 0.70 | 0.49 of the original |
| Fan power if the flow falls to 70 percent | 0.70 × 0.70 × 0.70 | 0.343 of the original, a saving of about 66 percent |
The mine moves far more tonnes of air than tonnes of ore. The last two rows are the reason mines try not to send air where nobody is working: this is the idea behind ventilation on demand.
Assumed inputs, not data from a particular mine. The fan laws are for the same fan and the same airways and ignore changes in efficiency. Statutory air quantities, air speeds and temperature limits differ by state and by type of mine.
Safety: underground ventilation is regulated and specific to each mine, and an underground mine must work to its own documented ventilation plan. Coal mines have separate and much stricter rules because of methane. This lesson shows principles; it is not a design method.
What the operator watches
- Airflow at fixed stations. The measured flow in each split is compared with the ventilation plan.
- Gas levels. Carbon monoxide and nitrogen dioxide from engines and blasting, and methane in coal mines.
- The main fan. Speed, pressure, motor load and vibration. A change in fan pressure at the same speed means something in the mine has changed.
- Doors, stoppings and ducts. A door left open or a torn duct changes where the air goes within minutes.
Common problems
- Recirculation. Used air finds its way back into the intake, for example when an auxiliary fan stands too close to the heading it serves, and gas and heat build up.
- Leakage and short circuits. Leaking stoppings and open doors let fresh air slip straight to the return, so the far workings receive less.
- Damaged duct. A torn or disconnected duct delivers little air to the face even though the auxiliary fan is running.
- Main fan trip. With the main fan stopped the airflow falls to almost nothing, so mines have set rules for withdrawing people and for restarting.
Words you will meet
- Intake / return
- Intake airways carry fresh air in; return airways carry used air out.
- Split
- One branch of the airflow that serves one working area.
- Stopping
- A wall built across an airway to block the air.
- Regulator
- An adjustable opening in a wall or door that limits the air in a split.
- Auxiliary fan and duct
- A small fan and a flexible or rigid tube that take air into a dead-end heading.
- Rise
- A steep or vertical opening that connects two levels.
- Recirculation
- Used air going round again instead of leaving the mine.
- Wet bulb temperature
- A temperature reading that includes the effect of humidity, used to judge heat stress.
Check your understanding
Why does a dead-end heading need an auxiliary fan and a duct?
It has no way through, so the main airflow passes its entrance and the air inside stands still. The fan and duct force fresh air to the face, and the used air flows back out along the heading.
Why does slowing the main fan a little save so much power?
Fan power rises with roughly the cube of the airflow. At 70 percent flow the fan needs about 0.343 of the power, a saving of about 66 percent.
What is recirculation and why is it dangerous?
Used, contaminated air returns to the intake side and is breathed again. Gas, dust and heat then build up instead of being carried out of the mine.