Petroleum Refinery (overview)

The whole refinery in process order, from crude tanks to converters and dispatch.

Loading the animation…
You are watching a free lesson. A free account saves your progress and lets you mark lessons complete. Create a free account Sign in

What a petroleum refinery does

A refinery separates crude oil into its parts by boiling point. Then it changes the heavy, low-value parts into lighter, more valuable fuels and cleans them of sulphur. Nothing is made from nothing: 100 units of crude go in and about 100 units of fuels, gas and other products come out, with a little burned as fuel for the plant itself.

Crude is stored in a tank farm and moved by centrifugal pumps. The first big separation takes place in the atmospheric distillation column. Gas is squeezed by compressors, and the plant uses a cooling tower and stacks. Waste and relief gas goes to the flare. Click a block in the drawing to open its own lesson, where one exists.

How it works

  1. Crude receipt and storage. Crude arrives by ship and pipeline into tanks. Several crudes may be blended so the plant gets a steady mix.
  2. Desalting. Wash water and an electric field remove the salt and water that would corrode and foul the equipment downstream.
  3. Heating. Heat exchangers recover heat from hot products. Then a fired heater brings the crude to about 350 to 370°C.
  4. Atmospheric distillation. The hot crude flashes in a tall column. Light parts rise and are drawn off high (gas, naphtha, kerosene or jet fuel, diesel), and the heavy residue falls out of the bottom.
  5. Vacuum distillation. The residue is heated again in a furnace and run under vacuum, so the heavy gas oil boils without cracking. What is left is vacuum residue.
  6. Upgrading and treating. A hydrotreater removes sulphur. A reformer raises the octane of naphtha. A catalytic cracker breaks heavy gas oil into petrol and LPG. Hydrogen sulphide goes to amine treating and then to sulphur recovery.
  7. Blending and dispatch. Components are blended to the fuel specification, tested, stored, and loaded to road, rail, pipeline and ship.

The numbers

Typical features. Atmospheric cut ranges differ between refineries, because they are set by the crude and the products wanted. Typically: gas and LPG leave the overhead; light naphtha boils up to about 90°C; heavy naphtha about 90 to 180°C; kerosene and jet about 150 to 250°C; diesel and light gas oil about 240 to 350°C; atmospheric residue is above about 350°C.

Typical conditions: the atmospheric column feed leaves the heater at about 350 to 370°C. The vacuum unit runs at a few tens of mmHg absolute, with a furnace outlet near 390 to 410°C. Hydrotreating typically runs at about 300 to 400°C with hydrogen at tens of bar. Reforming runs at about 480 to 520°C. In the catalytic cracker the riser is typically near 520 to 540°C and the regenerator near 650 to 730°C. Road fuels now carry very low sulphur limits, set by national fuel standards.

Worked example. Assume 100,000 barrels a day of crude and these illustrative straight-run yields, in percent of the crude volume.

QuantityWorkingResult
Crude volume100,000 bbl/d × 0.159 m³/bbl15,900 m³/d = 662 m³/h
Crude mass at 850 kg/m³662 × 0.850about 563 t/h
LPG and light gas, 2%100,000 × 0.022,000 bbl/d
Naphtha, 18%100,000 × 0.1818,000 bbl/d
Kerosene and jet, 14%100,000 × 0.1414,000 bbl/d
Diesel and gas oil, 24%100,000 × 0.2424,000 bbl/d
Vacuum gas oil, 22%100,000 × 0.2222,000 bbl/d
Vacuum residue, 20%100,000 × 0.2020,000 bbl/d (the six flows add up to 100,000)
Heat to warm the crude from 250 to 360°C (specific heat about 2.4 kJ/kg K)563,000 × 2.4 × 110 ÷ 3,600about 41,000 kW, about 41 MW, before the heat to vaporise it

The cracker, reformer and treaters then turn the vacuum gas oil and heavy naphtha into more petrol and diesel. This is why a real refinery makes more light product than the straight-run yields above.

Assumed inputs, not data from a particular plant or crude. Yields change with the crude, and which units a refinery has depends on the plant.

Safety: refineries handle flammable liquids and gases at high temperature and pressure, and toxic hydrogen sulphide. The design relies on relief systems, flares, gas detection, insulation and permits to work. Hot surfaces cause burns. This lesson explains the principle and is not an operating procedure.

What the operator watches

  • Column temperatures and product quality. The top and bottom temperatures and the tests on each cut show whether the column is separating well.
  • Desalter water level. The water level and the oil-water interface decide whether the salt is really removed.
  • Furnace outlet and tube skin temperatures. They show how much heat goes in and whether a tube is running too hot.
  • Hydrogen purity and catalyst activity. The converters depend on them.

Common problems

  • Salt carry-over. Salt that passes the desalter fouls the exchangers and corrodes the column top.
  • Furnace coking. A tube that runs too hot cokes inside, and the flow drops.
  • Flooding in a column. Too much vapour or liquid stops the trays separating.
  • Catalyst losing activity. Metals or coke on the catalyst cut the conversion.
  • Relief to the flare. A relief valve that lifts sends gas to the flare.

Words you will meet

Crude assay
The tests that describe a crude: its boiling curve, density, sulphur and other properties.
Cut point
The boiling temperature that divides one product from the next.
Reflux
Condensed liquid returned to the top of a column to improve the separation.
Flash zone
The part of a column where the hot feed enters and the vapour separates from the liquid.
Desalter
A vessel that washes the salt out of crude with water and an electric field.
Hydrotreating
Reacting oil with hydrogen over a catalyst to remove sulphur.
Octane
A measure of how well petrol resists knocking in an engine.
Cracking
Breaking large molecules into smaller ones, here with a hot catalyst.
Residue
The heavy liquid left at the bottom of a distillation column.
Flare
A tall stack that burns waste or relief gas safely.

Check your understanding

Why is the residue from the atmospheric column distilled under vacuum rather than just heated more?

Heated more, the heavy oil would crack into coke before it boiled. A vacuum lowers the boiling point, so the heavy gas oil can be boiled off at a lower temperature.

Why does the crude go through a desalter first?

Salt would corrode and foul the heat exchangers, the furnace tubes and the column.

Why does a real refinery make more petrol and diesel than the straight-run yield shows?

The converters, such as the catalytic cracker, break heavy oil into lighter products, so more of the crude ends up as the light products people want.

Key facts

Basic idea
Separate by boiling point, then convert and clean the heavy parts.
Heater outlet
About 350 to 370°C for the atmospheric column, typically.
Vacuum unit
Boils the heavy gas oil under a few tens of mmHg, indicative.
Converters
Hydrotreater, reformer and catalytic cracker add light product and remove sulphur.
Waste and relief gas
Goes to the flare, and hydrogen sulphide to sulphur recovery.
Use the animation
Follow the crude (dark brown) from the tanks through the desalter and the heater to the atmospheric column. Then follow the residue to the vacuum column, the light products (amber) to the converters, and the finished products to the blending tanks and the loading gantry. Gas is pale blue and goes to the amine and sulphur plant and the flare. Click a block that has its own lesson to open it. The numbers on the drawing match the numbered steps under How it works. Hover over any part for its name and what it does.