Feed through a filter and pump, membranes in vessels, clean permeate and brine.
Reverse osmosis (RO) makes clean water from salty or poor water by pushing it through a membrane. The membrane lets water molecules pass and holds back most of the dissolved salts. Two streams come out: clean water, called permeate, and a smaller, saltier stream called the concentrate or brine.
Plain osmosis moves water from the fresh side of a membrane to the salty side. Reverse osmosis forces it the other way, so it needs a pressure higher than the osmotic pressure of the water. The method is used for brackish groundwater, for seawater (see the seawater plant), for treated waste water that is being reused, and for the salty water that comes up with coal seam gas (see produced water treatment). The membranes are delicate, so the water must be clean when it arrives. An RO train is therefore the last part of a treatment line, behind steps such as those of a water treatment plant.
This lesson shows one RO train from feed to cleaning. The seawater plant lesson shows how such trains sit inside a whole desalination plant.
The more of the feed that becomes permeate, the saltier the concentrate gets, and the higher its osmotic pressure. At some point the pump pressure is hardly above the osmotic pressure at the end of the vessel and little more water will pass. Before that point, the salts in the concentrate reach the limit of what water can hold and start to form scale on the last elements. So the recovery is set by the osmotic pressure and by scaling, and the control valve is adjusted to stay below both.
Figures are typical and change with the water and the design. Brackish water is typically about 1,000 to 10,000 mg/L of salt. It is treated at about 10 to 30 bar (1 to 3 MPa) with a recovery of about 50 to 85 percent. Seawater is typically about 35,000 mg/L of salt, is treated at about 55 to 70 bar (5.5 to 7 MPa), and recovers only about 40 to 50 percent. A modern membrane typically holds back about 98 to 99.8 percent of the salt.
A cartridge filter is typically rated at about 1 to 5 micrometres. A common element is about 200 mm across (8 inch) and about 1 m long, with about 37 m² of membrane wound inside it. A vessel typically holds 6 to 8 elements in a row; the drawing shows three. The flux, the flow of permeate through each square metre of membrane, is typically about 15 to 25 L/(m²·h) for brackish water, and lower for seawater. As a rule of thumb, the osmotic pressure is about 0.077 MPa for every 1,000 mg/L of salt.
Assumed inputs: feed 200 m³/h of brackish water with 2,500 mg/L of salt (2.5 kg/m³); recovery 75 percent; 1 percent of the salt in the feed passes into the permeate; antiscalant dose 3 mg/L (3 g/m³); feed pressure 1.5 MPa; pump efficiency 80 percent; flux 20 L/(m²·h); 37 m² of membrane in each element; 6 elements in each vessel.
| Quantity | Working | Result |
|---|---|---|
| Permeate flow | 200 × 0.75 | 150 m³/h |
| Concentrate flow | 200 − 150 | 50 m³/h |
| Antiscalant used | 3 g/m³ × 200 m³/h | 600 g/h (0.6 kg/h) |
| Salt in the feed | 200 × 2.5 kg/m³ | 500 kg/h |
| Salt in the permeate | 1 percent of 500 = 5 kg/h, ÷ 150 m³/h | 0.033 kg/m³, about 33 mg/L |
| Salt in the concentrate | 500 − 5 = 495 kg/h, ÷ 50 m³/h | 9.9 kg/m³, about 9,900 mg/L (about 4 times the feed) |
| Osmotic pressure of the concentrate | 9.9 × 0.077 MPa | about 0.76 MPa, below the 1.5 MPa that the pump gives |
| Hydraulic power of the pump | (200 ÷ 3,600 m³/s) × 1,500 kPa | about 83.3 kW |
| Power at the pump shaft | 83.3 ÷ 0.80 | about 104 kW |
| Energy for each m³ of permeate | 104.2 kW ÷ 150 m³/h | about 0.69 kWh/m³ |
| Membrane area | 150 m³/h = 150,000 L/h, ÷ 20 L/(m²·h) | 7,500 m² |
| Number of elements | 7,500 ÷ 37 | 202.7, so 203 elements |
| Number of vessels | 203 ÷ 6 | 33.8, so 34 vessels (204 elements) |
The concentrate is about four times as salty as the feed, and it is the last elements of each vessel that meet it. That is where scale starts, and it is why the recovery cannot simply be pushed higher. Note also that the pressure has to beat the osmotic pressure of the concentrate, not of the feed.
Assumed inputs, not data from a particular plant. The salt content, the recovery, the pressure, the flux and the membrane performance change with the water and the design. The drawing leaves out the feed pump, the valves, the instruments, the second stage that many plants add, and the energy recovery device. The vessels hold fewer elements than a real one.
Safety: water at membrane pressure can injure, and a vessel holds that pressure. Antiscalant and cleaning chemicals, which include acids and alkalis, are corrosive. The design relies on pressure relief, interlocks, bunding and permits to work. This lesson explains the principle and is not an operating procedure.
Osmotic pressure pushes water from the fresh side to the salty side, the wrong way. Only a pressure above it, with some extra to drive the flow, pushes water through from the salty side to the fresh side. The concentrate at the end of the vessel is the saltiest, so it has the highest osmotic pressure.
More water is pushed through, so the permeate flow and the recovery rise. The concentrate leaves in a smaller flow and is saltier, which raises its osmotic pressure and the risk of scale.
The membranes are fouling or scaling. The train is stopped and cleaned in place from the cleaning tank. It is also worth checking the cartridge filter and the antiscalant dose, to see why the membranes were not protected.