cPipeHyd

Pressures, flows and pressure losses in a piping model: link a cPD model, say what the fluid is and where a pressure or a flow is known, and read the answer in 3D, in tables and in a report.

cPipeHyd overview: a piping model coloured by flow, velocity and pressure, then the results and the basis tables

Overview

A cPipeHyd document works out the flow in every pipe and the pressure at every node of a piping model drawn in the Cloud Piping Designer (cPD). You do not draw anything in cPipeHyd: the pipes, fittings, sizes and elevations come from a copy of the cPD model, and you add the fluid, the pipe material, the pressures and flows you know and the valve data.

  • The pressure loss of each pipe, bend, tee, reducer and valve is calculated, and so is the pressure change from the elevations.
  • The model can have branches and loops. The answer comes when you press Run: there is no queue and no waiting for a solver.
  • Every value you did not give is listed on the Basis tab as given, sourced or assumed, so you can see what the answer rests on.

cPipeHyd gives results and a record of how they were made. It does not check a design against a code. The full guide is in the User Manual chapter.

Access & the module

  • cPipeHyd is a module, like cPD or cTD: tick it when you book your plan (see Pricing). It adds $49 per seat per month on top of your other modules; the term and seat discounts apply. Questions? Contact us.
  • A Free account can make one cPipeHyd document a month, like cFEA, to try it; the paid module removes the limit. A paid account from before the module existed does not have it until it is booked.
  • Client users cannot use it. You need a cPD model in the project (see Getting Started), and the right to edit the project to make or change an analysis. Everyone who can open the project can look.

Getting Started

  1. Draw the piping in a cPD and Save it. Give the elements their sizes and elevations there.
  2. In the cPD editor click Pipe hydraulics in the bar on the left. It makes a cPipeHyd document in the same project, with the cPD already copied in, and opens it in a new tab. (An unsaved cPD is refused: the copy is of the saved file.) If one was already made from this cPD you are asked whether to open the newest or make another.
  3. Or use Deliverables → cPipeHyd and New cPipeHyd, then in step 1 choose the cPD and press Link this cPD.
  4. Work down the steps on the left. The 3D view on the right shows your piping, and the colours after a run. The page saves by itself a moment after every change.
The New cPipeHyd dialog.
The New cPipeHyd dialog.
A cPipeHyd document with its cPD model linked, and what is still missing before it can run.
A cPipeHyd document with its cPD model linked, and what is still missing before it can run.

The Five Steps

  1. Model. The linked cPD. If the cPD was changed afterwards the page lists the changes and offers Update from cPD. Anything the solver cannot use is listed under Not analysed (it stops the run) and To fix before running.
  2. Fluid and pipe. Choose a clear fluid (density and viscosity; the list offers water at 20 and 60 °C and seawater), a slurry or a paste (see below). Choose the pipe material (it sets the roughness) or type a roughness, and the friction law. You can give some pipes and fittings another material, and change the wall thickness of a pipe size.
  3. Pressures, flows and pipe sizes. For the case shown above the 3D view: where a pressure (kPa gauge) or a flow (m³/h) is known. A tank open to the air is a pressure: the liquid level times density times g, at the node's elevation. At least one pressure is needed in every connected part. You can also run the same system with other pipe sizes or another pipe material, in this case only.
  4. Valves and extra losses. For each valve, its type and its rated Cv or Kv from the maker's data sheet, and optionally the maker's curve against opening. A valve can be part open in a case. A K for an element the library does not cover (a strainer, a meter) can be added with its source.
  5. Run. Run this case or Run all cases, then Report.

Slurry and paste: the fluid is treated as a Bingham plastic. All three numbers are needed (density, plastic viscosity and yield stress); none is assumed. The friction method is the same as in the Calculations block Pipe Pressure Drop (Bingham Paste), which is on the public Calculations verification report. Settling is not modelled.

Cases

  • A case is one set of known pressures and flows, valve openings, pipe sizes and pipe material, for example normal flow and one pump off. The fluid, the valve data and the extra losses are shared by all cases.
  • Use the Case list above the 3D view; the … menu next to it makes a New case, a Copy, a Rename or a Delete. Steps 3 and 4, the 3D view, Results and Basis show the case you chose.
  • The Compare tab puts the cases side by side: convergence, largest velocity, lowest pressure, the pressure at every node and the flow in every pipe and valve.

Reading the Results

  • The chips at the top say whether a cPD is linked, whether the case is Ready to run, and whether the results are current or out of date. A change to the model or a setting marks the results out of date (the old ones stay on screen, labelled); run again.
  • 3D view: Colour by flow, velocity or pressure (the legend gives the range). Click a node for its pressure, head, flow and velocity, and to set a pressure or flow there. In Pipes and fittings mode a click selects elements, to give them a material or to set a valve's opening.
  • Results tab: a summary (converged, iterations, largest velocity), warnings, a table of links (a run of pipe and fittings between two junctions: flow, velocity, Reynolds number, loss) and a table of nodes (elevation, pressure in kPa gauge, head, flow out of the network). Both download as CSV.
  • A warning appears for a node at or below a perfect vacuum, a shut check valve, or a run that did not converge. Do not use the numbers at such a node.

The Basis

  • The Basis tab lists every value the run used, with its source and a status: given (you entered it), sourced (from the library's data), assumed or provisional. Giving a value in steps 2 to 4 replaces an assumed one.
  • Fitting losses use equivalent lengths (the L/D method) taken from the calculation sheets named in the Basis. A value that had to be worked out between the sheet's rows, such as a bend at an angle the sheet does not list, is marked assumed.
  • With nothing given for the fluid, water at 20 °C is used and the Basis says so. With no pipe material, carbon steel is assumed.

The Report

  • Press Report in step 5. The page takes pictures of the 3D view (the model, then each case coloured by flow, velocity and pressure) and opens the report in a new tab as a page, a PDF and a Word file.
  • It has a summary of the cases and their warnings, the model and the fluid, a section for each case, the basis with every assumed value marked and counted, what is not covered, and a sign-off block. It is a draft until your checker and approver sign it by hand.
  • The tables in the report stop at 300 rows; the CSV downloads have all of them.

What it Does Not Do

  • Steady, incompressible flow only. No water hammer or surge, no gas, steam or two-phase flow, no heat transfer (no heat loss, freeze protection or surface temperature).
  • Slurry and paste are a homogeneous Bingham plastic: no settling and no deposition-velocity check.
  • No pump in the set-up: a network is solved from known pressures and flows. No pump or control-valve selection and no cavitation or NPSH check.
  • A valve at part opening follows a standard characteristic (linear, equal percentage or quick opening) unless you enter the maker's curve.
  • No pipe stress, no code check, no relief or safety check. Pipe sizes are steel DN and schedule. A model with more than 600 junctions is refused. An expansion joint or a cross fitting is not analysed (a cross can be modelled as two tees).

Troubleshooting

  • cPipeHyd is not in my menus: it is a module. See Access & the module.
  • The Pipe hydraulics button is not in the cPD editor: it appears only with the module, and only for people who can edit the cPD's project.
  • "Not analysed ... this stops the run": read the message: it names the element. Typical causes are an expansion joint, a cross, a fitting with no size, or a valve with no type and no Cv (step 4).
  • "The network has no known pressure": give a pressure at a node (step 3). Flows alone are not enough. Every connected part of the model needs one.
  • "Did not converge": check the pumps, check valves and closed valves in the model.
  • Results out of date: something changed since the run. Run the case again. If the cPD changed, press Update from cPD first.
  • A node shows a pressure below vacuum: the boundary pressures and the elevations do not agree: check them.

FAQ

How is this different from a Piping System?

A Piping System is drawn as a diagram of nodes and pipes. cPipeHyd takes the real 3D piping from a cPD, with its sizes and elevations, so the model is drawn once and used for both.

Can I change the piping in cPipeHyd?

No. Change it in the cPD, save, then press Update from cPD. Your pressures, valve data and materials stay attached to the same nodes and elements; anything that points at something that is gone is reported.

Does a new revision keep my results?

Yes: the link, the set-up and the finished results are copied to the new revision, and the results show as out of date only if something differs.