Check a flange rating or a backing ring in a pipe class

Set the design conditions and flange class in the pipe class and read the Flange Rating Check, or the Backing Ring Check for HDPE pipe. For a single ring use the Plate Backing Ring Flange calculation.

← All guides

Before you start

A project with a Piping Material Specification (Specifications are on every plan). For the one-off check you need a Calculations document.

1 Open the Piping Material Specification

A project has one active Piping Material Specification: press the + (Add) control in the project's Specifications section and choose it in Specification Type if there is none yet. Inside it, Add Sheet adds one pipe class. Sheets save as you work.

Where: Deliverables > Specifications

Open Specifications →

2 Fill in the design basis of the pipe class

Enter the Pipe Class, the Description, the fluids, the Design Conditions (the temperature and pressure the class must work at; you can enter several), the Design Standard, the Flange Rating, the Material and the corrosion allowance, then the Pipe rows. The Flanges table holds a row for each size range: choose the flange Type and the Class (an ASME class such as Class 150, or an AS 2129 table). You do not need to type the pressure and temperature again for the check.

Specifications help →

3 Read the Flange Rating Check

The class's output lists a Flange Rating Check. The class set in Flange Rating and the class of each Flanges row are compared with every design condition. Ratings come from the ASME B16.5 tables (carbon steel group 1.1, stainless steel group 2.1) or the AS 2129 tables. Each line says OK (the pressure is within the rating at that temperature), EXCEEDED (above it) or NOT RATED (the temperature is above what the class is rated for). The Specification Summary shows the worst result, and the same table is in the pipe class appendix of the PDF.

4 For HDPE pipe: the Backing Ring Check

HDPE pipe is flanged with a stub end and a loose plate flange behind it, the backing ring. Plastic pipe has no flange class, so when the Material is HDPE the class has a Backing ring check block instead. Choose the Backing Ring Plate Flange series (ANSI B16.5 Class 150, PN16 which is the default, or AS 2129 Table D, E or H) and, if you wish, change the design stresses, the gasket factor m and the gasket seating stress y. The output lists one line for each pipe size that has ring data, checked at the highest design pressure of the class: plate thickness, minimum plate needed, stress against allowable, bolts, bolt torque range and the status OK or NOT OK.

5 Check one ring on its own with a calculation

In a calculation press Add Calculation Block, choose the Category Pipe Design and the type Plate Backing Ring Flange (AS 1210). Enter the design pressure, the stresses, the gasket values, the stub end lip diameters, the ring outside diameter, bore, bolt circle and plate thickness, and the number and size of bolts. The result is OK or NOT OK, with the stress, the Minimum Plate Thickness, the bolt area required and provided, and the minimum and maximum bolt torque.

Open Calculations →

6 Act on a NOT OK

NOT OK means the plate stress is above the allowable (the plate is thinner than the minimum shown: use a thicker plate or a heavier series) or the bolts fitted give less area than required (fit more or larger bolts). An error message instead of numbers means the geometry cannot work, for example the bolt circle is outside the ring.

7 Export

Export the specification as PDF or Word. The Flange Rating Check and the Backing Ring Check are in the appendix of each pipe class.

Tips

  • The backing ring check follows the AS 1210 backing ring method. The PN16 and AS 2129 plate dimensions come from a supplier's table: confirm them against your project standard.
  • A gasket seating stress y of 0 means a soft rubber gasket, so only the operating condition is checked. Enter a value above 0 to check the seating condition as well.

Common mistakes

  • Expecting a flange check on a plastic class. HDPE gets the backing ring check; PP-R and PVC-U use other flange systems and are not covered.
  • Assuming the stub end is checked. It is not, and neither are external loads.

Something here does not match what you see, or your question is not covered? Tell us.