Size a pump for a water or slurry line

A quick sizing with calculation blocks (friction loss, then head, power and NPSH available), or a full network in a Piping System that finds where a pump curve meets the system.

← All guides

Before you start

A project. Calculations and Piping Systems are on every plan (a free plan has a monthly limit on how many documents of each type you can add).

1 Choose the quick way or the network way

Use calculation blocks for a single line when you want the duty point to specify. Use a Piping System when there are several pipes, tanks, valves, a pump curve to test, or several scenarios (normal and fire case, for example).

2 Friction loss of the line (calculation)

Add a calculation to the project, press Add Calculation Block, choose the Category Hydraulics and the type Pipe Pressure Drop. Enter Flow Rate (m3/h) and Pipe Length (m), choose the Pipe Material, Pipe Size (DN) and Schedule (the roughness and the inside diameter come from the pipe charts), and the Fluid with its temperature (20 degC unless you change it; the density and viscosity come from the fluid tables). For a pipe or fluid that is not in the lists, choose User-defined and type the inside diameter, roughness, density and viscosity. Press Calculate All: the result is the Pressure Drop in kPa, with the velocity, Reynolds number and friction factor, and the diameter, roughness, density and viscosity that were used.

Open Calculations →

3 Head, power and NPSH available (calculation)

Add a second block, the type Pump Sizing. It asks for Flow Rate, Suction Pressure and Discharge Pressure (both in bar), Fluid Density, Fluid Viscosity, Elevation Difference, Pump Efficiency (%), Vapor Pressure and, if you know it, NPSH Available (override). It returns Total Dynamic Head (m), Pump Power (kW), NPSHa (m) and Specific Speed. The head is the pressure rise from suction to discharge divided by density and gravity, plus the Elevation Difference.

4 Feed one block from the other, mind the units

Beside an input is a button to reference another block's output. A reference converts the unit for you: a kPa output from the pipe block can feed the bar input of the pump block, and the picker lists it with "kPa → bar, converted" (only outputs of the same kind of quantity are offered). NPSHa is worked out only when the Suction Pressure is above zero, and it takes the Suction Pressure and the Vapour Pressure as absolute pressures (gauge plus atmospheric); otherwise type your own value in NPSH Available (override). Specific Speed assumes a 1450 rpm motor.

5 Or model the network in a Piping System

Add a Piping System to the project. Add the nodes (tank, junction, pump, valves), connect them with pipes that have a diameter, length and material, set the flows, and press Calculate. In Design mode the engine reports the pressures and losses a duty needs. In Analysis mode it takes the pump curve and finds the flow and head where the curve meets the system resistance, with power, efficiency and NPSH margin.

Where: Deliverables > Piping Systems

Open Piping Systems →

6 Use the supplier's curve for a slurry

Open the pump's curve dialog and enter the head-flow points (type them, paste two columns from Excel, or trace them with From picture). Supplier curves are for clean water. Leave the curve as a clean-water curve and set the liquid SG and viscosity: the engine corrects head and efficiency for a settling slurry (d50 above 50 micrometres) or a viscous liquid, or you can enter the supplier's own ratios.

Piping Systems help →

7 Record the duty on the pump datasheet

Add a datasheet of type Pump with the SubType Slurry or Water, and enter the duty. In the Piping System you can right-click the pump and choose Datasheet link... to create the datasheet from the equipment and keep chosen values up to date from the calculated results. You are asked before anything changes.

Guide: Specify a pump or mixer on a datasheet →

Tips

  • A Piping System can show the hydraulic grade line (HGL/EGL) for each branch, a good check that the pressures along the line make sense.
  • For a thick paste with a yield stress, use the Bingham paste block instead: a Newtonian friction loss underestimates it.

Common mistakes

  • Entering a gauge pressure where Pump Sizing asks for the absolute Suction Pressure (NPSHa comes out too low by about 1 bar).
  • Reading a clean-water supplier curve as the duty of a settling slurry without the slurry correction.
  • Solving a Piping System before every pipe has a diameter, length and material: Calculate will list what is missing.

Something here does not match what you see, or your question is not covered? Tell us.