What a mine water supply does
A mine needs water every day: to crush, grind and separate the ore, to keep dust down on the roads, and for the people in the camp. In a dry country the water often has to come from far away. A water supply system finds the water, moves it to the site, stores it, cleans the part that needs cleaning and shares it out.
The animation is a diagram on a block of ground, not a map. Nothing is to scale. It follows the water from the bores on the left to the raw water dam, then to the process plant, the camp and the dust cart, and back from the tailings storage. It adds to the mine water balance, which counts every flow, and to mine dewatering, which is about getting unwanted water out of the mine.
How it works
The water runs through seven stages. The numbers on the drawing match the numbers here.
- 1Bore field. A production bore is a drilled hole lined with a casing. A slotted screen lets in water where the hole passes through an aquifer, which is rock or sand that holds water. A submersible pump at the bottom pushes the water up a riser pipe to the wellhead. Pumping lowers the water level around the bore in the shape of a cone, so bores are spaced apart. Compare the dewatering bore, which looks the same but removes water instead of supplying it.
- 2Borrow pit or dam. A borrow pit is a pit dug to take earth for roads and dams. Rain, runoff or groundwater can fill it, so it can serve as a second source. A pump on the bank lifts the water into the pipeline. Surface water rises and falls with the weather and is lost to evaporation, so it usually supports the bores and does not replace them.
- 3Pipeline and booster pumps. A pipeline carries the water from the sources to the mine. It is sized for a flow speed of about 1 to 2 m/s: a slower flow needs a wider, dearer pipe, and a faster flow loses more energy to friction and makes pressure surges worse. A booster pump station adds pressure part way along. Valves on each side isolate the pump, and the pump starts and stops slowly so that the water in the pipe is not shocked. See the centrifugal pump.
- 4Raw water dam. The dam stores the water, typically enough for a week to a month of use. Supply and demand are never equal: a bore pump may be out of service, or the plant may run harder for a week. The dam smooths this out. Its level is kept between a low and a high mark. It is lined or built to limit seepage, and some of its water is lost to evaporation.
- 5Treatment. Most uses need only raw water. Drinking water and a few clean uses in the plant need more. A clarifier lets the fine solids settle with the help of a chemical that makes them clump, filters take out the last fine solids, and a small dose of chlorine disinfects the water. If the water is salty, a reverse osmosis plant does the job instead. See the water treatment plant.
- 6Distribution. Raw water leaves the dam in more than one pipe. One goes to the process plant, which is the largest user. One has a stand pipe where the water cart fills to spray the roads (see haul road watering). Treated water goes to the camp in its own pipes. Valves and meters at each split decide how much goes where.
- 7Water balance. Meters on the bore field, the pipeline, the dam outlet, the plant and the return line make the account possible. Most of the plant's water does not come from the dam: it comes back from the tailings storage as return water (see tailings storage). The supply only has to replace what is lost: evaporation, water locked in the tailings and the product, and the water on the roads.
The numbers
Typical figures (all depend on the mine and the climate):
- A production bore typically yields about 10 to 50 L/s.
- Pipelines typically run at 1 to 2 m/s.
- A raw water dam typically holds about a week to a month of the site's use.
- A processing plant typically needs about 0.4 to 1.5 m³ of fresh water for each tonne of ore, after reusing the return water.
- A camp typically uses about 150 to 300 litres of water for each person each day.
- Drinking water typically keeps a chlorine residual of about 0.2 to 1 mg/L at the tap.
To convert: 1 L/s is 86.4 m³ a day, and 1 L/s for a year is about 31.5 ML. The power a pump gives to the water is the density (1,000 kg/m³) × 9.81 × the flow (m³/s) × the head (m), in watts.
Worked example. Assume a plant that treats 15,000 tonnes of ore a day and uses 2.5 m³ of water for each tonne, and 76 percent of that comes back as return water. The camp has 600 people using 250 litres each a day. Dust suppression takes ten loads of 30 m³ a day. The raw water dam covers 6 hectares (60,000 m²), is 3 m deep on average, and loses 2.0 m of water a year to evaporation. Bores yield 25 L/s each and run 90 percent of the time. The pipeline speed is 1.5 m/s, the booster pumps lift the water 120 m, the pump efficiency is 75 percent and the motor efficiency 95 percent. A treated stream of 500 m³/day (the camp and the clean uses in the plant) goes through the treatment train at a clarifier rate of 1 m/h (24 m/day), a filter rate of 5 m/h (120 m/day) and a chlorine dose of 3 mg/L (3 g/m³).
| Quantity | Working | Result |
|---|
| Plant water use | 15,000 t/day × 2.5 m³/t | 37,500 m³/day |
| Return water | 37,500 × 0.76 | 28,500 m³/day |
| Fresh water for the plant | 37,500 − 28,500 | 9,000 m³/day |
| Camp | 600 × 250 L ÷ 1,000 | 150 m³/day |
| Dust suppression | 10 loads × 30 m³ | 300 m³/day |
| Evaporation from the dam | 60,000 m² × 2.0 m ÷ 365 | 329 m³/day |
| Total supply needed | 9,000 + 150 + 300 + 329 | 9,779 m³/day |
| As a flow | 9,779 ÷ 86.4 | 113.2 L/s |
| Bores needed | 25 × 0.90 = 22.5 L/s each; 113.2 ÷ 22.5 = 5.03 | 6 bores (5 give 112.5 L/s, just short) |
| Pipe diameter | area = 0.1132 ÷ 1.5 = 0.0755 m²; d = √(4 × 0.0755 ÷ π) | about 310 mm |
| Booster hydraulic power | 1,000 × 9.81 × 0.1132 × 120 | about 133 kW |
| Booster electrical power | 133 ÷ 0.75 ÷ 0.95 | about 187 kW |
| Dam storage | 60,000 m² × 3 m = 180,000 m³; ÷ 9,779 | about 18.4 days |
| Clarifier area | 500 ÷ 24 | about 20.8 m² |
| Filter area | 500 ÷ 120 | about 4.2 m² |
| Chlorine | 500 m³ × 3 g/m³ | 1,500 g = 1.5 kg/day |
Notice how much the return water saves: without it the plant would need 37,500 m³ a day, about four times as much, and every figure down the supply line would be four times larger. The plant uses 9,000 of the 9,779 m³/day, so the water balance of the plant is the water balance of the mine.
Assumed inputs, not data from a particular mine. A real design also allows for droughts, seepage, pipe friction, pipe pressure ratings and the water quality of each source.
Safety: this lesson is education, not a procedure. Bores, pressure pipelines, pumps, dams and chlorine are hazardous. Work on them follows the site's own isolation, permit and confined space rules, and drinking water is treated and tested to the rules that apply to it.
What the operator watches
- Dam level. Kept between the low and high marks. A level that keeps falling means the supply is too small or something leaks.
- Bore water level and pump current. A falling water level or a rising current warns of a worn pump or a blocked screen.
- Pipeline pressure and flow. A sudden fall in pressure with the same pumping usually means a leak or a burst.
- Chlorine residual and clarity. Checked on the treated water every day.
- Meters. The totals are compared with the water balance. A meter that disagrees with the others is checked.
Common problems
- Falling bore yield. The aquifer is drawn down, or the screens are blocked by iron or scale. Bores are cleaned or rested, and new ones are added.
- Pipeline leak or burst. The pipe holds a lot of water under pressure. A leak wastes water and can wash out the ground. Valves along the line isolate the section.
- Pressure surge. A sudden pump stop or a valve shut too fast sends a shock wave along the pipe. Slow-closing valves and slow starts prevent it.
- Poor quality. Salty or dirty water can harm the plant, so bores are tested and sources are blended.
- Dry spell. Surface sources dry up first. The dam is the reserve, and the plant can cut its use by recycling more.
Words you will meet
- Aquifer
- Rock or sand that holds and yields water.
- Bore
- A drilled hole, lined with a casing, from which water is pumped.
- Drawdown
- How far pumping lowers the water level around a bore.
- Borrow pit
- A pit dug to take earth, which can fill with water.
- Booster pump
- A pump part way along a pipeline that adds pressure.
- Water hammer
- A pressure surge in a pipe after a sudden change of flow.
- Raw water
- Water as it comes from the source, before any treatment.
- Return water
- Water recovered from the tailings and used again.
- Make-up water
- The fresh water that replaces what the mine loses.
Check your understanding
Why keep a raw water dam instead of pumping the bores straight to the plant?
The bores cannot be matched to the plant moment by moment. A bore pump may be out of service, and the plant may use more in some weeks. The dam holds a reserve of days to weeks and smooths the difference.
Why is the fresh water the plant needs so much smaller than the water it uses?
Most of the water that goes through the plant leaves with the tailings, but the tailings storage lets the solids settle and returns the water. In the example the plant uses 37,500 m³/day but only 9,000 m³/day must be fresh.
Why not run the pipeline at 3 m/s to use a smaller pipe?
A smaller pipe is cheaper, but the friction loss rises quickly with speed, so the pumps need much more power. A pressure surge after a sudden stop is also bigger. That is why pipelines are usually kept at about 1 to 2 m/s.