What carbon capture and storage does
Burning fuel and many industrial processes make carbon dioxide, written CO2. Carbon capture and storage, CCS, takes the CO2 out of the gas before it reaches the air, turns it into a dense dry fluid, carries it by pipeline to a well, and pumps it deep underground into porous rock, where it stays. It is a chain of five jobs: capture, compress, transport, inject and monitor.
The capture step is the same kind of plant as amine treating. In amine treating the amine takes hydrogen sulphide out of a gas. Here the amine takes carbon dioxide out of flue gas, and the same loop of absorber and regenerator does the work. The compressor is a larger relative of the gas compressor, and the well is described in its own lesson, the CO2 injection well. Where the CO2 comes from a gas plant instead of a boiler, the same amine unit of the gas processing plant already separates it, and the chain starts at the compressor.
How it works
- Flue gas source. A boiler, furnace or process burns fuel and makes flue gas. The CO2 in it is only a small share of the gas, typically 4 to 15 percent by volume, and the rest is mostly nitrogen. A fan pushes the gas through a duct to the capture plant. Real plants first cool the gas and take out dust and acid gases that would spoil the amine. The drawing leaves those steps out.
- Absorber. The flue gas enters the bottom of the absorber, a tall column with trays, and rises. Cool lean amine runs down from the top. On each tray the amine takes up CO2, so the gas gets cleaner going up. The gas with most of its CO2 removed leaves the top and is released. The amine that has taken up the CO2 is rich amine, and the darker purple on the drawing shows it.
- Regenerator. A pump, not drawn, sends the rich amine to the regenerator, another column. A heat exchanger, not drawn, warms it on the way with the hot lean amine. Steam heats a reboiler at the bottom, which makes vapour that rises through the trays. The heat undoes the bond between the amine and the CO2 and drives the CO2 out. The CO2 leaves the top, and a condenser, not drawn, takes out the water vapour. The lean amine leaves the bottom, is cooled and returns to the absorber. The reboiler uses most of the energy of the plant.
- Compression and drying. The CO2 leaves the regenerator at close to atmospheric pressure, so it takes up a huge volume. A multi-stage compressor raises it to typically 10 to 15 MPa. A cooler after each stage takes out the heat of compression, and the CO2 becomes a dense fluid, much like a liquid. A dehydration unit takes out the water. Wet CO2 forms a weak acid that corrodes steel, so the CO2 must be dry.
- Pipeline. The dense CO2 flows through a steel pipeline to the storage site. Block valves can shut it off, and booster stations add pressure on a long line. Most pipelines are buried. The drawing shows this one above ground so you can see it. Dry CO2 does not corrode carbon steel pipe, and the dense fluid carries a lot of mass in a small pipe.
- Injection well. At the site the pipeline joins the wellhead. A master valve and a quick-closing safety valve control the flow. The CO2 runs down the tubing inside a steel casing cemented into the hole, and a packer seals the space around the tubing. The CO2 leaves through holes in the casing, the perforations, at the storage depth. The CO2 injection well lesson shows the inside.
- Storage reservoir and monitoring. The CO2 enters the pores of a deep sandstone, the reservoir, which are full of salty water called brine. It pushes the brine away, and, being lighter, it rises until it lies under a thick layer of tight rock, the caprock, which stops it going further. The spreading CO2 is the plume. A separate monitoring well with gauges, water samples from shallow bores, and surveys from the surface check that the plume goes where it was predicted to go.
The numbers
Typical features: the capture plant removes typically 85 to 95 percent of the CO2 in the flue gas. The amine is mixed in water at typically 20 to 40 percent by weight, and the regenerator reboiler runs at about 115 to 125°C. Capture takes typically 2.5 to 4 GJ of heat for each tonne of CO2. The compressor raises the CO2 to typically 10 to 15 MPa, and compression takes typically 80 to 120 kWh for each tonne. CO2 becomes a dense fluid above its critical point, 7.38 MPa and 31.1°C. Stores are typically deeper than about 800 m so that the CO2 stays dense, and many are 1,000 to 3,000 m deep.
Worked example, one capture plant and one store. Assume a source that emits 1,000,000 tonnes of CO2 a year, 90 percent captured, 8,000 operating hours a year, a reboiler need of 3.5 GJ per tonne, a compression need of 100 kWh per tonne, a CO2 density of 750 kg/m³ in the store and about 1.9 kg/m³ as a gas at atmospheric pressure.
| Quantity | Working | Result |
|---|
| CO2 captured in a year | 1,000,000 × 0.90 | 900,000 t |
| Captured in an hour | 900,000 ÷ 8,000 | 112.5 t/h |
| Heat for the reboiler | 112.5 × 3.5 | about 394 GJ/h |
| The same as a power | 394 ÷ 3.6 (1 MW = 3.6 GJ/h) | about 109 MW of heat |
| Compression power | 112.5 × 100 ÷ 1,000 | about 11 MW |
| Volume of the gas at atmospheric pressure | 112,500 kg/h ÷ 1.9 kg/m³ | about 59,000 m³/h |
| Volume of the dense CO2 in the store | 112,500 kg/h ÷ 750 kg/m³ | 150 m³/h |
| How much smaller it is | 59,000 ÷ 150 | about 390 times |
The last rows show why the CO2 is compressed: the same mass takes a few hundred times less room in the pipe and in the rock. The first rows show the cost: the capture plant needs heat and power on the scale of a small power station, which is why capture adds to the fuel a plant uses. The drawing leaves out the flue gas cooler, the fan, the condenser, the amine cooler, the lean and rich exchanger, the cooling water and the pumps, and it shows far fewer trays than a real column.
Assumed inputs, not data from a particular plant. The emission, the capture rate, the energy figures and the densities change with the source, the solvent and the site.
Safety: carbon dioxide is colourless and heavier than air. At high concentration it displaces oxygen and can cause unconsciousness, and it collects in low places and enclosed spaces. The pipeline, compressor and well hold very high pressure, and CO2 released from pressure becomes very cold. The amine and the hot regenerator are also hazards. The design relies on gas detection, ventilation, relief valves, shut-off valves and permits to work. This lesson explains the principle and is not an operating procedure.
What the operator watches
- CO2 in the gas leaving the absorber. It is the product test. A rise means less is being captured.
- Amine circulation and reboiler steam. They must match the CO2 load. Too little leaves CO2 in the gas, and too much wastes energy.
- Water content of the CO2 and the compressor discharge pressure and temperature. Wet CO2 corrodes, and a wrong pressure puts the CO2 in the wrong phase.
- Pipeline and wellhead pressure, injection rate and annulus pressure. They show that the CO2 is going where it should.
- Monitoring well readings and water samples. They show where the plume has reached and whether anything has reached the groundwater.
Common problems
- Solvent damage. Oxygen, heat and impurities in the flue gas break the amine down. It then foams, corrodes and loses strength.
- Water in the CO2. It makes acid that corrodes the pipe and the well, and it can form solid hydrates that block lines.
- Impurities. Oxygen, sulphur compounds or nitrogen change the density of the CO2, the corrosion risk and the limits set for the store.
- Pressure in the store. If CO2 is injected faster than the rock can take it, the pressure rises toward the level that could fracture the rock, so the rate is limited.
- Energy cost. The heat and power needed for capture and compression are a large part of the cost.
Words you will meet
- Flue gas
- The gas that leaves a boiler, furnace or process after burning.
- Absorber
- The column where the amine takes up the CO2.
- Regenerator
- The column where heat drives the CO2 out of the amine.
- Lean and rich amine
- Amine with little CO2 in it, and amine that has taken it up.
- Dense phase
- CO2 held above its critical point so that it is a dense fluid, neither an ordinary gas nor an ordinary liquid.
- Caprock
- Tight rock above the reservoir that stops the CO2 rising.
- Plume
- The region of the reservoir that the injected CO2 has spread through.
- Monitoring
- Measurements that show where the CO2 is and that it is staying there.
Check your understanding
Why is the CO2 compressed before it goes into the pipeline?
At atmospheric pressure the CO2 is a gas that takes up a huge volume. At 10 to 15 MPa it is a dense fluid that takes a few hundred times less room, so a smaller pipe and well can carry it, and the pressure is high enough to push it into the rock.
Why does the regenerator need so much heat?
The amine holds the CO2 with a chemical bond. Heat is needed to break that bond, and to make the steam that carries the CO2 away. This is the main energy cost of capture.
What keeps the CO2 from coming back up?
The CO2 is stored deep, below a thick caprock that lets it through only extremely slowly. The well is sealed with cemented casing and a packer. A monitoring well and surface surveys check that the plume stays where it was predicted to stay.